![APRILIA SHIVER 900 Service Station Manual Download Page 152](http://html1.mh-extra.com/html/aprilia/shiver-900/shiver-900_service-station-manual_2956571152.webp)
(PIN 3): if NOT OK, restore the wiring harness; if OK, check the continuity of the Green/
Black cable (between PIN 3 of the sensor connector and ENGINE PIN 32) and restore the
wiring harness.
•
If open circuit, short circuit to negative: check the continuity from the probe connector (PIN
3 and 4) to the probe: if NOT OK, replace the probe; if ok, perform the check procedure for
the sensor connector and for the Marelli control unit connector: if NOT OK restore; if OK,
with the key ON and the sensor connector disconnected, check if there is battery voltage at
PIN 4: if NOT OK, check the continuity of the Red/Brown cable between the probe connector
and the injection relay (no. 17 in the electrical circuit diagram, position under the left side of
the tank; however, CHECK the relay identification with the cable colours); if there are also
errors regarding the coils, injectors and secondary air, check the relay and its energy and
power line; if there is voltage at PIN 4, check ground insulation of the Green/Black cable
(PIN 3): if NOT OK, restore the wiring harness; if OK, check the continuity of the Green/
Black cable (between PIN 3 of the sensor connector and ENGINE PIN 32) and restore the
wiring harness.
WARNING
The control unit does not detect the following malfunctions of the lambda probe circuit relative
to the signal: interrupted circuit, short circuit to ground or malfunction of the sensor (for ex-
ample, voltage not variable). If the indication is abnormal, perform the troubleshooting indicated
below.
Troubleshooting
•
Check the continuity of the circuit from the probe connector (PIN 1 and PIN 2) towards the
probe: replace the lambda probe if there is no continuity; if there is continuity, check the
sensor connector and the Marelli control unit connector: if NOT OK, restore; if OK, check
the continuity between the ENGINE connector PIN 10 and PIN 22 and restore the wiring
harness.
DIAGNOSTIC TOOL: LOGIC ERRORS
P0134 Front lambda probe
Functional diagnosis:
•
no switching from high / no switching from low
Error cause:
•
If no switching from high: is shown when the ratio control is in closed loop and when the
secondary air valve is not operating. The error is validated if the engine is in CUTOFF status
and the probe signal is close to 1V, or if the engine is in another operating condition that
requires the injection but the switching from the"HIGH RATIO" to "LOW RATIO" is missing
for a certain"adjusted" number of dead points (PMS or TDC).
•
If no switching from low: is shown when the ratio control is in closed loop and when the
secondary air valve is not operating. The error is validated if during the ratio control stage,
Electrical system
SHIVER 900
ELE SYS - 152
Summary of Contents for SHIVER 900
Page 1: ...SERVICE STATION MANUAL 2Q000335 SHIVER 900...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR...
Page 55: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS...
Page 63: ...SHIVER 900 Special tools S TOOLS 63...
Page 64: ...INDEX OF TOPICS MAINTENANCE MAIN...
Page 76: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS...
Page 195: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE...
Page 206: ...INDEX OF TOPICS ENGINE ENG...
Page 284: ...INDEX OF TOPICS POWER SUPPLY P SUPP...
Page 289: ...INDEX OF TOPICS SUSPENSIONS SUSP...
Page 319: ...INDEX OF TOPICS CHASSIS CHAS...
Page 355: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS...
Page 384: ...INDEX OF TOPICS CLUTCH SYSTEM CLU SYS...
Page 388: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS...
Page 400: ...INDEX OF TOPICS BODYWORK BODYW...
Page 437: ...SHIVER 900 Bodywork BODYW 437...
Page 438: ...INDEX OF TOPICS PRE DELIVERY PRE DE...
Page 444: ...U Use 288 364 W Water pump 393 Wiring diagram 111...