APR APR-HHA Instructions Manual Download Page 2

7.

Inside

 

head,

 

locate

 

and

 

disconnect

 

large

 

white

 

3

pin

 

power

 

connector

 

and

 

4

pin

 

small

 

RTD

 

connector

 

for

 

APR

HHA

heater

 

head

8.

Locate

 

and

 

remove

 

3x

 

spring

loaded

 

APR

HHA

 

head

 

mounting

 

screws

 

from

 

bottom

 

holes

 

as

 

shown

 

(3/32”

 

allen

key);

 

as

 

last

 

screw

 

removed

 

hold

 

the

 

HHA

 

and

 

carefully

 

allow

 

it

 

to

 

drop

 

to

 

‘rest’

 

position;

 

it

 

will

 

be

 

held

 

in

 

place

 

by

the

 

2x

 

airflow

 

tubes

 

in

 

rear

9.

While

 

holding

 

the

 

HHA

 

head,

 

remove

 

both

 

blue

banded

 

and

 

white

banded

 

airflow

 

tubes

 

from

 

rear

 

of

 

head

 

and

slowly

 

drop

 

HHA

 

head

 

below

 

vacuum

 

tube

 

end

 

to

 

remove

 

completely

IMPORTANT!

 

WHLE

 

REMOVING

 

HEAD

 

BE

 

CAREFUL

 

NOT

 

TO

 

BEND

 

VACUUM

 

TUBE!

4

pin

 

RTD

 

conn

 

3

pin

 

POWER

 

conn

 

3x

 

access

 

holes

 

for

 

HHA

 

mount

 

screws

 

3x

 

access

 

HHA

 

mounting

 

screws

 

3/32”

 

long

 

straight

 

driver

 

type

 

hex

 

allen

 

key

 

preferred

 

AIRFLOW

 

TUBING

Blue

banded

 

TOP

 

White

banded

 

BOTTOM

Summary of Contents for APR-HHA

Page 1: ...or vacuum cups from heater head vacuum tube 3 Remove 6x rear screws head face cover disconnect LED 2 pin wire harness and remove cover 4 As shown manually hold air cylinder lever in down position to allow movement of the vacuum tube 5 Place finger at bottom of vacuum tube and gently lift upward to topmost up position 6 Release air cylinder lever to lock tube in up position this will help protect t...

Page 2: ...t position it will be held in place by the 2x airflow tubes in rear 9 While holding the HHA head remove both blue banded and white banded airflow tubes from rear of head and slowly drop HHA head below vacuum tube end to remove completely IMPORTANT WHLE REMOVING HEAD BE CAREFUL NOT TO BEND VACUUM TUBE 4 pin RTD conn 3 pin POWER conn 3x access holes for HHA mount screws 3x access HHA mounting screws...

Page 3: ...g head in place carefully install 2x airflow tubes to rear pipes IMPORTANT BLUE BANDED TUBE installed at TOP WHITE BANDED TUBE installed at BOTTOM If installing these flow tubes in error it will generate an overtemp error when running heater head 15 Carefully move head upward install 3x mounting screws through bottom holes and attach the head to the casting bottom NOTE 3 32 hex allen key with long...

Page 4: ...hole on nozzle ring 21 Tighten nozzle lever with a slight turn using pliers 22 To adjust rotation travel pull off the lever boot and use 035 hex allen key to adjust small set screw inside lever handle when rotating the nozzle should have some slight drag and not be too loose Use small pointed instrument like pick to carefully squeeze together sides of female U shaped connector in order to make goo...

Page 5: ...ed and bring down reflow nozzle edge to about 0 25 10 0mm above board level Switch to FINE speed and adjust to 5 10 mil or as needed Bring the head down until the reflow nozzle edges are just above board level 28 Examine all 4 sides of the reflow nozzle edges with respect to board level All 4 sides should be parallel to board level 29 If nozzle edges are not parallel or co planar adjust the 3 spri...

Page 6: ...ftware manual mode put the vacuum tube in FREE Use a finger to lift up vacuum pipette so that it is at same approximate level as bottom nozzle edge then put the vacuum tube in LOCK old soft Down to keep pipe in place 33 Pull out the camera In COARSE mode lower the head to where the reflow nozzle bottom edge is about 1 25 4mm above the camera Be careful not to hit the camera with the nozzle or pipe...

Page 7: ...te to accommodate each side of a full nozzle rotation 4 edges 38 After centering the vacuum pipette to the nozzle box tighten the 4 screws on the upper plate and re verify centering NOTE If the 3 spring loaded heater head screws described in Section 3 are adjusted off and nozzle is hanging too much at an angle it may not be possible to center the pipette in the box this is why it important to perf...

Page 8: ...40 Check vacuum tube FREE function in manual mode if head is misaligned the tube may contact and scrape at the bottom grille hole edge ...

Reviews: