APR APR-HHA Instructions Manual Download Page 1

APR

HHA

 

HEATER

 

HEAD

 

REMOVE

INSTALL

 

INSTRUCTIONS

 

Required

 

Tools:

 

3/32”

 

hex

 

allen

 

L

key

 

3/32”

 

hex

 

allen

 

key

 

(long

 

straight

 

driver

 

type

 

preferred)

 

7/16”

 

hex

 

allen

 

key

 

REMOVAL

 

1.

Machine

 

is

 

OFF;

 

head

 

is

 

at

 

top

 

home

 

position

 

(preferred)

2.

Remove

 

any

 

nozzles

 

and/or

 

vacuum

 

cups

 

from

 

heater

 

head/vacuum

 

tube

3.

Remove

 

6x

 

rear

 

screws

 

head

 

face

 

cover;

 

disconnect

 

LED

 

2

pin

 

wire

 

harness

 

and

 

remove

 

cover

4.

As

 

shown,

 

manually

 

hold

 

air

 

cylinder

 

lever

 

in

 

down

 

position

 

to

 

allow

 

movement

 

of

 

the

 

vacuum

 

tube

5.

Place

 

finger

 

at

 

bottom

 

of

 

vacuum

 

tube

 

and

 

gently

 

lift

 

upward

 

to

 

topmost

 

‘up’

 

position

6.

Release

 

air

 

cylinder

 

lever

 

to

 

lock

 

tube

 

in

 

up

 

position

 

(this

 

will

 

help

 

‘protect’

 

the

 

tube

 

when

 

removing

 

heater

 

head)

Head

 

face

 

cover

 

Summary of Contents for APR-HHA

Page 1: ...or vacuum cups from heater head vacuum tube 3 Remove 6x rear screws head face cover disconnect LED 2 pin wire harness and remove cover 4 As shown manually hold air cylinder lever in down position to allow movement of the vacuum tube 5 Place finger at bottom of vacuum tube and gently lift upward to topmost up position 6 Release air cylinder lever to lock tube in up position this will help protect t...

Page 2: ...t position it will be held in place by the 2x airflow tubes in rear 9 While holding the HHA head remove both blue banded and white banded airflow tubes from rear of head and slowly drop HHA head below vacuum tube end to remove completely IMPORTANT WHLE REMOVING HEAD BE CAREFUL NOT TO BEND VACUUM TUBE 4 pin RTD conn 3 pin POWER conn 3x access holes for HHA mount screws 3x access HHA mounting screws...

Page 3: ...g head in place carefully install 2x airflow tubes to rear pipes IMPORTANT BLUE BANDED TUBE installed at TOP WHITE BANDED TUBE installed at BOTTOM If installing these flow tubes in error it will generate an overtemp error when running heater head 15 Carefully move head upward install 3x mounting screws through bottom holes and attach the head to the casting bottom NOTE 3 32 hex allen key with long...

Page 4: ...hole on nozzle ring 21 Tighten nozzle lever with a slight turn using pliers 22 To adjust rotation travel pull off the lever boot and use 035 hex allen key to adjust small set screw inside lever handle when rotating the nozzle should have some slight drag and not be too loose Use small pointed instrument like pick to carefully squeeze together sides of female U shaped connector in order to make goo...

Page 5: ...ed and bring down reflow nozzle edge to about 0 25 10 0mm above board level Switch to FINE speed and adjust to 5 10 mil or as needed Bring the head down until the reflow nozzle edges are just above board level 28 Examine all 4 sides of the reflow nozzle edges with respect to board level All 4 sides should be parallel to board level 29 If nozzle edges are not parallel or co planar adjust the 3 spri...

Page 6: ...ftware manual mode put the vacuum tube in FREE Use a finger to lift up vacuum pipette so that it is at same approximate level as bottom nozzle edge then put the vacuum tube in LOCK old soft Down to keep pipe in place 33 Pull out the camera In COARSE mode lower the head to where the reflow nozzle bottom edge is about 1 25 4mm above the camera Be careful not to hit the camera with the nozzle or pipe...

Page 7: ...te to accommodate each side of a full nozzle rotation 4 edges 38 After centering the vacuum pipette to the nozzle box tighten the 4 screws on the upper plate and re verify centering NOTE If the 3 spring loaded heater head screws described in Section 3 are adjusted off and nozzle is hanging too much at an angle it may not be possible to center the pipette in the box this is why it important to perf...

Page 8: ...40 Check vacuum tube FREE function in manual mode if head is misaligned the tube may contact and scrape at the bottom grille hole edge ...

Reviews: