1D Barcode Scanner Setting Manual
V1.10
Appendix - Instruction Set
Function
instructions
Hexadecimal instructions
1. Turn on scanning without
timeout
NA
02 01 01 01 00 00 00 00 00 00 00 00 00
00 03 F8
2. Turn on scanning timeout 3
seconds
NA
02 01 01 02 B8 0B 00 00 00 00 00 00 00
00 03 34
3. Turn on scanning timeout 10
seconds
NA
02 01 01 02 10 27 00 00 00 00 00 00 00
00 03 C0
4. Close the scan
NA
02 01 01 00 00 00 00 00 00 00 00 00 00
00 03 F9
5. Restore default settings
000B0
02 02 06 82 30 30 30 42 30 00 00 00 00
00 03 6F
6. Check the software version
000A0
02 02 06 82 30 30 30 41 30 00 00 00 00
00 03 70
7. Enter Setup
09990
02 02 06 82 30 39 39 39 30 00 00 00 00
00 03 66
8. Exit Setup
09991
02 02 06 82 30 39 39 39 31 00 00 00 00
00 03 65
9. Transmit
Programming
Barcode Data
02501
02 02 06 82 30 32 35 30 31 00 00 00 00
00 03 79
10.Not Transmit Programming 02500
02 02 06 82 30 32 35 30 30 00 00 00 00
73
/
102
Summary of Contents for appLS15I
Page 1: ......
Page 17: ...1D Barcode Scanner Setting Manual V1 10 Italy Italian France French 17 102 ...
Page 19: ...1D Barcode Scanner Setting Manual V1 10 Switzerland German French Croatian Croatian 19 102 ...
Page 35: ...1D Barcode Scanner Setting Manual V1 10 023900 Unhide the middle character 35 102 ...
Page 95: ...1D Barcode Scanner Setting Manual V1 10 1148 Down arrow 1149 Up arrow 95 102 ...