background image

™ 

Voyager™ 1200g/1202g

Single-Line Laser Bar Code Scanner

User’s Guide

Summary of Contents for VOYAGER 1200G

Page 1: ... Voyager 1200g 1202g Single Line Laser Bar Code Scanner User s Guide ...

Page 2: ...nformation that is protected by copyright All rights are reserved No part of this document may be photocopied repro duced or translated into another language without the prior written consent of HII 2010 2011 Honeywell International Inc All rights reserved Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of t...

Page 3: ...o correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help If necessary the user should consult the dealer ...

Page 4: ...t indésirable C UL Statement C UL listed CSA C22 2 No 60950 1 07 Second Edition Europe The CE marking indicates compliance to 2004 108 EC EMC Directive with Standards EN55022 CLASS B EN55024 EN61000 3 2 EN61000 3 3 In addition complies to 2006 95 EC Low Voltage Direc tive when shipped with recommended power supply For further information please contact Honeywell Imaging Mobility Europe BV Nijverhe...

Page 5: ...ct should not be disposed of along with municipal waste and invites you to use the appropriate separate take back systems for product disposal If you need more information on the collection reuse and recycling sys tems please contact your local or regional waste administration You may also contact your supplier for more information on the environ mental performances of this product Germany GS Stat...

Page 6: ...cordance with and complies with IEC60825 1 ed2 0 and 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PROD UCT 1 0 mW MAX OUTPUT 630 650nM Scanner Laser Beam Wavelength 645 660 nm Divergence 1 5 mrad per IEC 60825 1 worst case Max power output 1mw The laser diode is considered an embedded laser Intra...

Page 7: ...controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation expo sure Patents For patent information please refer to www honeywellaidc com patents Solids and Water Protection The Voyager 1200g has a rating of IP42 immunity of foreign particles and drip ping water ...

Page 8: ... been tested with cables less than 3 meters Cables greater than 3 meters may not meet class B performance UL Statement UL listed UL60950 1 Second Edition Canada Industry Canada This device complies with Canadian RSS 210 Operation is subject to the following conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired...

Page 9: ... standards EN 300 328 EN 301 489 1 EN 301 489 17 EN60950 1 Waste Electrical and Electronic Equipment Information Honeywell complies with Directive 2002 96 EC OF THE EUROPEAN PAR LIAMENT AND OF THE COUNCIL on waste electrical and electronic equipment WEEE This product has required the extraction and use of natural resources for its production It may contain hazardous substances that could impact he...

Page 10: ...s of this product Australia NZ C Tick Statement Conforms to AS NZS 3548 EMC requirements China SRRC Radio Certificate CCC safety CCB00 010BT base only Japan Complies with Technical Regulations Conformity Certification of Specified Radio equipment Korea This product meets Korean agency approval Russia Gost R certificate Taiwan If the following label is attached to your product the product meets Tai...

Page 11: ...and complies with IEC60825 1 ed2 0 and 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PROD UCT 1 0 mW MAX OUTPUT 630 650nM Scanner Laser Beam Wavelength 645 660 nm Divergence 1 5 mrad per IEC 60825 1 worst case Max power output 1mw The laser diode is considered an embedded laser Intrabeam viewing o...

Page 12: ...controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation expo sure Patents For patent information please refer to www honeywellaidc com patents Solids and Water Protection The Voyager 1202g has a rating of IP42 immunity of foreign particles and drip ping water ...

Page 13: ...Voyager 1200g Safety Label Locations Laser Output Compliance Markings information Part Number and Serial Number information Compliance Markings information Internal Laser Cautions ...

Page 14: ...oyager 1202g Safety Label Locations Laser Output Compliance Markings information Part Number and Serial Number information Compliance Markings information Internal Laser Cautions Laser Safety Information ...

Page 15: ...CCB00 010BT Safety Label Locations Item Number Serial Number and Compliance Markings information Compliance Markings information ...

Page 16: ......

Page 17: ...stom Defaults 1 9 Resetting the Factory Defaults 1 9 Chapter 2 Programming the Interface Introduction 2 1 Programming the Interface Plug and Play 2 1 Keyboard Wedge 2 1 IBM PS2 Keyboard 2 1 RS232 Serial Port 2 1 RS485 2 2 OPOS Mode 2 3 USB IBM SurePos 2 4 IBM Secondary Interface 2 4 USB PC or Macintosh Keyboard 2 5 USB HID 2 5 HID Fallback Mode 2 5 USB Serial Commands 2 6 USB Serial Emulation 2 6 ...

Page 18: ...4 Keyboard Style 2 15 Keyboard Conversion 2 16 Keyboard Modifiers 2 16 Inter Scan Code Delay 2 17 F0 Break Character 2 18 Keyboard Wedge Defaults 2 18 RS232 Modifiers 2 19 RS232 Baud Rate 2 19 RS232 Word Length Data Bits Stop Bits and Parity 2 20 RS232 Handshaking 2 21 RS232 Timeout 2 22 XON XOFF 2 23 ACK NAK 2 23 Communication Timeout 2 23 NAK Retries 2 24 Support BEL CAN in ACK NAK 2 25 RS232 De...

Page 19: ...d Back Into Range 3 3 Out of Range and Back into Range with Batch Mode On 3 3 Page Button 3 3 About the Battery 3 4 Voyager 1202g Battery Removal 3 4 Charging Information 3 4 Battery Recommendations 3 5 Proper Disposal of the Battery 3 6 Flash Updates 3 6 Beeper and LED Sequences and Meaning 3 6 Scanner LED Sequences and Meaning 3 6 Base LED Sequences and Meaning 3 7 Base Power Communication Indic...

Page 20: ...8 Clear All Codes 3 18 Transmit Records Automatically 3 19 Transmit Records to Host 3 19 Batch Mode Transmit Delay 3 20 Scanner Name 3 20 Using the Scanner with Bluetooth Devices 3 22 Changing the Scanner s Bluetooth PIN Code 3 22 Minimizing Bluetooth ISM Band Network Activity 3 22 Auto Reconnect Mode 3 23 Maximum Link Attempts 3 24 Relink Time Out 3 24 Bluetooth ISM Network Activity Examples 3 24...

Page 21: ... 4 11 CodeGate 4 12 Object Detection Mode 4 12 End Object Detection After Good Read 4 13 Object Detection Laser Timeout 4 13 Object Detection Distance 4 14 Character Activation Mode 4 14 Activation Character 4 14 End Character Activation After Good Read 4 15 Character Activation Laser Timeout 4 15 Character Deactivation Mode 4 16 Deactivation Character 4 16 Reread Delay 4 17 User Specified Reread ...

Page 22: ...Communication Check Character 5 6 Intercharacter Interfunction and Intermessage Delays 5 7 Intercharacter Delay 5 7 User Specified Intercharacter Delay 5 7 Interfunction Delay 5 8 Intermessage Delay 5 9 Chapter 6 Data Formatting Data Format Editor Introduction 6 1 To Add a Data Format 6 1 Other Programming Selections 6 3 Terminal ID Table 6 4 Data Format Editor Commands 6 4 Move Commands 6 5 Searc...

Page 23: ... 7 19 Code 11 7 21 Code 128 7 24 ISBT 128 7 25 GS1 128 7 31 Telepen 7 33 UPC A 7 35 UPC A EAN 13 with Extended Coupon Code 7 38 UPC A Number System 4 Addenda Required 7 38 UPC A Number System 5 Addenda Required 7 39 UPC E0 7 41 EAN JAN 13 7 45 EAN 13 Beginning with 2 Addenda Required 7 46 EAN 13 Beginning with 290 Addenda Required 7 47 EAN 13 Beginning with 378 379 Addenda Required 7 47 EAN 13 Beg...

Page 24: ...65 Postal Codes 7 66 China Post Hong Kong 2 of 5 7 66 Chapter 8 Interface Keys Keyboard Function Relationships 8 1 Supported Interface Keys 8 2 Chapter 9 Utilities To Add a Test Code I D Prefix to All Symbologies 9 1 Show Software Revision 9 1 Show Data Format 9 1 Test Menu 9 2 EZConfig Scanning Introduction 9 2 Installing EZConfig Scanning from the Web 9 3 Chapter 10 Serial Programming Commands C...

Page 25: ...9 USB 11 10 Chapter 12 Maintenance Repairs 12 1 Maintenance 12 1 Cleaning the Device 12 1 Inspecting Cords and Connectors 12 1 Replacing Cables in Corded Scanners 12 1 Replacing an Interface Cable in a Corded Scanner 12 2 Replacing Cables in Cordless Systems 12 2 Replacing an Interface Cable in a Base 12 2 Troubleshooting a Voyager Scanner 12 3 Troubleshooting a Cordless System 12 4 Troubleshootin...

Page 26: ...x ASCII Conversion Chart Code Page 1252 A 4 Code Page Mapping of Printed Barcodes A 6 ...

Page 27: ...on terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide An asterisk next to an option indicates the default setting Unpacking Your Device After you open the shipping carton containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered th...

Page 28: ...ort of a computer 1 Connect the appropriate interface cable to the scanner first then to the computer 2 Make sure the cables are secured in the wireways in the bottom of the base and that the base sits flat on a horizontal surface 3 The scanner beeps Charge and Communications Base USB Connection ...

Page 29: ...e available at www honeywellaidc com Connecting with Keyboard Wedge A scanner or base can be connected between the keyboard and PC as a keyboard wedge where the scanner provides data output that is similar to keyboard entries The following is an example of a keyboard wedge con nection 1 Turn off power and disconnect the keyboard cable from the back of the terminal computer Connect the appropriate ...

Page 30: ... back on The scanner beeps 4 Verify the scanner or base operation by scanning a bar code from the Sample Symbols in the back of this manual The scanner beeps once The unit defaults to an IBM PC AT and compatibles keyboard wedge inter face with a USA keyboard A carriage return CR suffix is added to bar code data Charge and Communications Base Keyboard Wedge Connection ...

Page 31: ... computer 2 Connect the appropriate interface cable to the scanner Note For the scanner or base to work properly you must have the correct cable for your type of terminal computer only if power supply is included Charge and Communications Base RS232 Serial Port Connection ...

Page 32: ...e two screws to secure the connector to the port 5 Once the scanner or base has been fully connected power up the computer This interface programs 9600 baud 8 data bits no parity and 1 stop bit Connecting with RS485 A scanner or base can be connected for an IBM POS terminal interface 1 Connect the appropriate interface cable to the device then to the com puter Charge and Communications Base RS485 ...

Page 33: ...n the scanner is closer to the code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or ele ments mil size should be read farther from the unit To read single or multiple symbols on a page or on an object hold the scanner at an appropriate dis tance from the target press the button and cent...

Page 34: ...g the Save Defaults bar code also causes both the scanner and the base to perform a reset and become unlinked The scanner must be placed in its base to re establish the link before any setup codes are entered See Cordless System Operation beginning on page 3 1 for additional information You may have a series of custom settings and want to correct a single setting To do so just scan the new setting...

Page 35: ...Defaults If you aren t sure what programming options are in your scanner or you ve changed some options and want to restore the scanner to factory default set tings first scan the Remove Custom Defaults bar code then scan Activate Defaults This resets the scanner to the factory default settings Note If using a cordless system scanning the Activate Defaults bar code also causes both the scanner and...

Page 36: ...1 10 ...

Page 37: ...oard wedge is the default interface Note The following bar code also programs a carriage return CR suffix IBM PS2 Keyboard The following bar code programs you scanner for an IBM PS2 keyboard wedge interface with a USA keyboard Note The following bar code also programs a carriage return CR suffix RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or te...

Page 38: ...ol ogy Suffixes programmed for Code 128 with IBM 4683 Port 5B IBM 4683 Port 9B HHBCR 1 and IBM 4683 Port 17 Interfaces Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR 2 Interface Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 00 0A 0B UPC E 0A Code 128 00 18 0B RS232 Interface IBM Port 5B Interface IBM Port 9B HHBCR 1...

Page 39: ... XON XOFF Off ACK NAK Off Data Bits Stop Bits and Parity 8 Data 1 Stop Parity None Prefix Suffix Clear All Prefixes and Suffixes Add Code ID and AIM ID Prefix Add CR Suffix Intercharacter Delay Off Symbologies Enable UPC A with check digit and number system Enable UPC E0 with check digit Enable EAN JAN 8 with check digit Enable EAN JAN 13 with check digit Enable Code 128 Enable Code 39 Enable OPOS...

Page 40: ...IBM cash registers it may be necessary to disable the sec ondary or management interface In particular it has been found neces sary on IBM registers using the 4690 V2R4 operating system The following bar codes are used for this purpose Default Enable Secondary Interface Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC ...

Page 41: ...igured for Serial Emulation Mode but the host system does not have the correct driver the scanner would fail If you set the HID Fallback Mode for a set length of time for example 5 minutes the scanner would change to a HID keyboard interface after 5 minutes of trying to configure as serial emulation A unique beep sequence indicates that this mode has been entered While in HID Fallback Mode the sca...

Page 42: ...s PC you will need to download a driver from the Honeywell website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh computers recognize the scanner as a USB CDC class device and automatically uses a class driver Scanning either of these codes also adds a CR and LF Note No extra configuration e g baud rate is necessary CTS RTS Emulation HID Fallback Mode ...

Page 43: ...canning Save Default 2000 ms Timeout Retries This setting limits the number of Communication Timeout retries If the Timeout Retries is set to 0 the transmission is terminated after the ini tial Communication Timeout Scan the bar code below then set the number of retries from 0 255 by scanning digits from the Programming Chart then scanning Save 5 is the recommended set ting Default 0 ACK NAK Mode ...

Page 44: ...s that can occur in ACK NAK mode Scan the bar code below then set the number of retries from 0 255 by scanning digits from the Programming Chart then scanning Save 5 is the recommended setting Default 0 or disabled Support BEL CAN in ACK NAK This protocol responds to BEL and CAN commands when in ACK NAK mode The scanner sounds an error tone when a BEL command is sent from the host CAN terminates t...

Page 45: ...9 first then scan the programming code above Gilbarco Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Gilbarco terminal This bar code sets the baud rate to 2400 bps and the data format to 7 data bits even parity 2 stop bits It also adds a carriage return CR suffix and programs the following prefixes for each symbology Note If you are having unexpected r...

Page 46: ...tic scanner auxiliary port configuration This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 9 first then scan the programming code above NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner fo...

Page 47: ... Scan the following Plug and Play code to program the scanner for a Wincor Nix dorf terminal This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 9 first then scan the programming code above NCR Bioptic Settings Wincor Nixdorf Terminal S...

Page 48: ...r each symbol ogy Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 9 first then scan the programming code above Symbology Prefix Symbology Prefix Code 128 K EAN 13 A Code 93 L GS1 128 P Codabar N Interleaved 2 of 5 I UPC A A0 Plessey O UPC E C Straight 2 of 5 IATA H EAN 8 B All other bar codes M Wincor Nixdorf Beetle Settings ...

Page 49: ...m the keyboard layout for your country or language As a general rule the following characters are sup ported but need special care for countries other than the United States United States Belgium Finland Germany France IBM Financial Hungary Arabic Chinese Italy Japan ASCII Korea ...

Page 50: ...cters from the extended ASCII chart for example an e with an accent grave è you will use ALT Mode See Extended ASCII Characters on page A 5 Note Scan the ALT mode bar code after scanning the appropriate Keyboard Country code United Kingdom Turkey Q Switzerland German Russia Slovenia Spain Thailand Vietnam ...

Page 51: ...e This programs keyboard styles such as Caps Lock and Shift Lock If you have used Keyboard Conversion settings they will override any of the fol lowing Keyboard Style settings Default Regular Regular is used when you normally have the Caps Lock key off Caps Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not com mon to U S ke...

Page 52: ... power cycle your computer Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lowercase So if you have the following bar code abc569GK you can make the output ABC569GK by scanning Convert All Characters to Upper Case or to abc569gk by scanning Convert All Characters to Lower Case These settings override Keyboard Style selections Default Keyboard Conversion...

Page 53: ...or values 00 1F refer to the ASCII chart for Non Printable Characters page A 4 but it does not transmit any prefix or suffix information Default Control ASCII Mode Off Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default Off Inter Scan Code Delay When your keyboard detects that any key is being pressed released or held down the keyboard sends a packet of informa...

Page 54: ...ressed or held down A break code is sent when a key is released The following selections allow you to suppress or transmit the character sequence of the break code Default Transmit Keyboard Wedge Defaults If you want the custom keyboard wedge default settings restored to your scanner scan the Keyboard Wedge Defaults bar code below This resets the scanner to the custom default settings see Setting ...

Page 55: ...2 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 9600 300 2400 600 1200 4800 38400 9600 19200 115 200 57 600 ...

Page 56: ...equire use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 8 Data 1 Stop Parity None 8 Data 1 Stop Parity Even 7 Data 2 ...

Page 57: ...rol No Timeout The scanner asserts RTS when it has a character to send and will wait indefinitely for CTS to be asserted by the host Two Direction Flow Control The scanner asserts RTS when it is OK for the host to transmit The host asserts CTS when it is OK for the device to transmit Flow Control with Timeout The scanner asserts RTS when it has data to send and waits for a delay see RS232 Timeout ...

Page 58: ...ger 1202 RS232 Timeout When using Flow Control with Timeout you must program the length of the delay you want to wait for CTS from the host Set the length in millisec onds for a timeout by scanning the bar code below then setting the time out from 1 5100 milliseconds by scanning digits from the Programming Chart then scanning Save Default 1000 ms 1 second Flow Control No Timeout RTS CTS Off Two Di...

Page 59: ... response from the host If ACK is received the communications cycle is completed and the scanner looks for more bar codes If NAK is received the last set of bar code data is retransmitted and the scanner waits for ACK NAK again Turn on the ACK NAK protocol by scanning the ACK NAK On bar code below To turn off the protocol scan ACK NAK Off Default ACK NAK Off Communication Timeout This allows you t...

Page 60: ...d set ting Default 0 Communication Timeout Beeper This selection programs the scanner to issue an error beep when a communication timeout has occurred The error beep sound is pro grammed using Number of Beeps Error page 4 4 Default On NAK Retries This selection limits the number of NAK retries that can occur in ACK NAK mode Scan the bar code below then set the number of retries from 0 255 by scann...

Page 61: ... the RS232 Defaults bar code below This resets the scanner to the custom default settings see Setting Custom Defaults on page 1 8 If there are no custom defaults it will reset the scanner to the factory default settings Any settings that have not been specified through the custom defaults will be restored to the factory default settings NCR Modifiers NCR ACK NAK This is an NCR communication protoc...

Page 62: ... for the NCR prefix typically 02 for STX Scan the bar code below then set the hex number from 0 FF by scanning digits from the Programming Chart then scanning Save Default 0 NCR Suffix This selection allows you to program an NCR specific suffix Refer to the ASCII Conversion Chart Code Page 1252 on page A 4 to find the hex equivalent for the characters you want for the NCR suffix typically 03 for E...

Page 63: ...he bar code to a price parameter When set to On the error tone sounds set via Number of Beeps Error page 4 4 for an NOF and disables the scanner while the cashier looks up the price manually When set to Off no sound is emitted for an NOF Default Off Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners Note The scan...

Page 64: ...s If NAK is received the last set of bar code data is retransmitted and the scanner waits for ACK NAK again Turn on the ACK NAK protocol by scanning the ACK NAK On bar code below To turn off the protocol scan ACK NAK Off Default ACK NAK Off Communication Timeout This allows you to set the length in milliseconds for a timeout for the host ACK NAK response Scan the bar code below then set the timeou...

Page 65: ...sual indicator support power on diagnostics and data translation required for the host system The cordless charge base is also a scanner s battery charger Refer to Charging Information page 3 4 for additional information Linking the Scanner to a Base Turn off power before connecting a base then power up the computer once the base is fully connected When the base is connected and powered up put the...

Page 66: ...ation between the scanner and the base When data is scanned the data is sent to the host system via the base The cordless scanner recognizes data acknowledgement ACK from the base If it cannot be determined that the data has been properly sent to the base the scanner issues an error indication You must then check to see if the scanned data was received by the host system RF Radio Frequency Module ...

Page 67: ...base can also sound an alarm Refer to Out of Range Alarm page 3 12 Scanner Is Moved Back Into Range The scanner relinks if the scanner or the base have been reset or the scanner comes back into range If the scanner relinks you will hear a sin gle chirp when the relinking process is complete Refer to Out of Range Alarm on page 3 12 for further information Out of Range and Back into Range with Batch...

Page 68: ... cordless scanner by a rechargeable battery that is inte grated in the scanner handle Batteries are shipped approximately 30 to 60 charged The battery should be charged for a minimum of 4 hours before initial use to ensure optimal performance Voyager 1202g Battery Removal Charging Information The battery is designed to charge while the scanner is positioned in the base unit Refer to Base LED Seque...

Page 69: ...e it could damage the scanner Although your battery can be recharged many times it will eventually be depleted Replace it after the battery is unable to hold an adequate charge If you are not sure if the battery or charger is working properly send it to Honeywell International Inc or an authorized service center for inspection Refer to Customer Support on page 13 1 for additional information Cauti...

Page 70: ...effective to locate a local recycle disposal company Flash Updates The scanner can be flashed either in the base or out of the base however it is recommended that you flash the scanner while it is in the base Flash updates cannot be completed when the scanner is out of the base and the battery is low or when the scanner is out of range Beeper and LED Sequences and Meaning The scanner contains LEDs...

Page 71: ... Successful menu change Red blinking Razz or error tone Unsuccessful menu change Red LED Host Communication Red LED Communication Condition Off Power off USB suspend On continuously Power on system idle Short blinks Occurs while transferring data to from the RF module or the host port Receiving data Green LED Scanner Battery Green LED Charge Condition Off Battery not detected or charge suspended S...

Page 72: ... Off Default Scanning in Cradle On Note When Scanning in Cradle Off is selected the scanner will not scan any bar codes while it is in the base It will only scan when removed from the base Paging Paging Mode By default the paging button on the base pages the scanner associated with that base If you want the paging button on your base to be disabled scan the following Paging Mode Off bar code When ...

Page 73: ... button on the base the scanner associated with that base will begin beeping see Page Button on page 3 3 You can set the pitch of the paging beep for the scanner by scanning one of the follow ing bar codes Default Low Error Indicators Scanner Address Scan the following bar code to determine the address of the scanner you are using Paging Mode On Paging Mode Off Low 1000 Hz Medium 3250 Hz High 4200...

Page 74: ...the base scan the Charge Only Mode bar code Any subsequent scanners placed in that base will charge without linking to it The scanner used to program the base remains linked to the base To unlink this scanner scan Unlink Scanner on page 3 11 Note When in Charge Only Mode the scanner periodically wakes up and beeps See Power Up Beeper on page 4 1 to change this setting If you want to charge a scann...

Page 75: ...nal scanner by scanning the Unlink Scanner bar code See Scanner Modes page 3 10 Open Link Mode Single Scanner When newly shipped or defaulted to factory settings a scanner is not linked to a base A link is established when the scanner is placed into a base When in Open Link Mode a new link is established when a new scanner is placed in the base Each time a scanner is placed into a base the scanner...

Page 76: ...ation expires Note If you are out of range when you scan a bar code you will receive an error tone even if you do not have the alarm set You receive the error tone since the data could not be communicated to the base or the host Alarm Sound Type Set the alarm type for the scanner by scanning the following appropriate bar code If the alarm is on the scanner will emit 3 long high pitched beeps Defau...

Page 77: ...reset If Scanning While in Base Cradle page 3 8 is disabled the scanner will still go into power down mode Default 3600 seconds Note When the scanner is in power down mode press the scanner s button to power the unit back up There will be a set of power up beeps and a delay of up to a few seconds for the radio to join The scanner will then be ready to use Batch Mode Batch mode is used to store bar...

Page 78: ...ll any bar codes scanned generate an error tone In order to scan bar codes again the data must be transmitted to the base Default Batch Mode Off Batch Mode Beep When scanning in Batch Mode the scanner beeps every time a bar code is scanned When Batch Mode Beep is On you will also hear a click when each bar code is sent to the host If you do not want to hear these clicks scan Batch Mode Beep Off De...

Page 79: ...ill be 2345 Example Add a quantity of 5 for the last item scanned 1 Scan the item s bar code 2 Scan the quantity 5 bar code Example Add a quantity of 1 500 for the last item scanned 1 Scan the item s bar code 2 Scan the quantity 1 bar code 3 Scan the quantity 5 bar code 4 Scan the quantity 0 bar code 5 Scan the quantity 0 bar code Example Change a quantity of 103 to 10 To correct an incorrect quan...

Page 80: ...3 16 Quantity Codes 1 0 3 2 4 6 5 7 8 9 ...

Page 81: ...r code scanned in Batch Mode scan Record Counter On Your batch output would add a sequen tial number before each bar code for example 00001 bar code 1 00002 bar code 2 Default Record Counter Off Total Records If you wish to output the total number of bar codes scanned when in Batch Mode scan Total Records Delete Last Code Record Counter On Record Counter Off Total Records ...

Page 82: ...de after the data has been transmitted to the host system scan Clear All Codes After Transmission If you do not want the buffer cleared after transmission scan Don t Clear All Codes After Transmission Default Don t Clear All Codes After Transmission Clear All Codes If you want to clear the scanner s buffer of all data accumulated in Batch Mode scan Clear All Codes Batch Mode LIFO Batch Mode FIFO D...

Page 83: ...placed in the base scan the Don t Transmit Records Automatically bar code Default Don t Transmit Records Automatically Transmit Records to Host If you are operating in Inventory Batch Mode see Inventory Batch Mode on page 3 14 and your scanner is set to Don t Transmit Records Automat ically you must scan the following bar code to transmit all stored records to the host system Don t Transmit Record...

Page 84: ...ditional information Scanner Name You may assign a name to each scanner you are using for identification pur poses The default name is Voyager Perform the rename operation using either the bar codes on page 3 21 or by sending the serial command Voyager BT_NAMname where name is the new name for the scanner If you wish to change the names of additional scanners link them to the base one at a time an...

Page 85: ...For example if you wanted to name the linked scanner 312 you would scan the following bar code scan the 3 1 and 2 bar codes on the Programming Chart inside the back cover of this manual then scan Save Scan the Reset bar code and wait for the scanner to relink to the base To output the name of the scanner scan the following bar code The name will be output showing the product name model number and ...

Page 86: ...ging the Scanner s Bluetooth PIN Code Some devices require a PIN code as part of the Bluetooth security fea tures Your scanner s default PIN is 0000 which you may need to enter the first time you connect to your non base Bluetooth device To change the PIN scan the following bar code and then scan the appropriate numeric bar codes from the Programming Chart inside the back cover of this man ual The...

Page 87: ...cally If maximum number of link attempts is unsuccessful then the scanner must be relinked by either pressing the scanner s button or placing the scanner in the base See Maximum Link Attempts on page 3 24 The scanner is relinked by pressing the button Base reset firmware upgrade or power cycle Scanner behaves as if out of range No attempt to relink made while base is powered off Button must be pre...

Page 88: ... to try to link until the Power Time Out Timer setting see page 3 13 expires When Auto Reconnect Mode is Off setting Maximum Link Attempts to zero will cause the scanner to only attempt linking one time after a button press Relink Time Out Relink Time Out controls the idle time between relink attempts An attempt to link a scanner to a base typically lasts up to 5 seconds This is the time when the ...

Page 89: ... relink When the scanner s button is pressed 15 attempts are made to link to the base Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time After 15 cycles 8 15 120 or about 2 minutes the scanner stops trying to connect to the base but retains any bar codes that may have been saved in batch mode After one hour the scanner powers off and batch mode data ...

Page 90: ...3 26 ...

Page 91: ...fault Power Up Beeper On Scanner Beep on BEL Character You may wish to force the scanner to beep upon a command sent from the host If you scan the following Beep on BEL On bar code the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Power Up Beeper Off Scanner Power Up Beeper On Scanner Beep on BEL Off Beep on BEL On ...

Page 92: ...is option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High Beeper Good Read On Beeper Good Read Off High Medium Off Low ...

Page 93: ...good read beep occurs The scanner can be set to emit the good read beep either before or after data transmission Default Before Transmission Beeper Pitch Error The beeper pitch codes modify the pitch frequency of the sound the scan ner emits when there is a bad read or error Default Razz Low 1600 Hz Medium 2350 Hz High 4200 Hz Before Transmission After Transmission Razz 100 Hz Medium 2000 Hz High ...

Page 94: ...another Note The LEDs can also be programmed separately See LED Settings on page 4 6 To change the number of beeps scan the following bar code and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Number of Beeps Error The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from ...

Page 95: ...the number of error beeps scan the following bar code and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Number of Error Beeps LED Flashes ...

Page 96: ...ing bar codes to program the LED indicators LED Settings Default Red LED On with Laser Green LED On with Good Scan Green LED Off Red LED Off Green LED On with Good Scan Red LED On with Good Scan Green LED On with Laser Red LED On with Laser Red LED On when CodeGate Disabled Green LED On when CodeGate Disabled Green LED On when In Stand Red LED On when In Stand ...

Page 97: ...4 7 Red LED On with CTS Green LED On with CTS Red LED On when Battery is Low Green LED On when Battery is Low ...

Page 98: ...eld Caution When working with In Stand and Out of Stand settings enable the settings you want before disabling those you do not want to use If you disable settings first you may program the scanner so it is unable to read bar codes if this happens power cycle the scanner and scan the defaults bar code on page 1 9 Green Off Red Off Green Low Red Low Green Medium Red Medium Red High Green High ...

Page 99: ...owing commands to adjust how the scanner behaves when it is out of the stand Note If you are using a cordless charge base in Presentation Mode the battery will not charge unless the power supply is plugged into the base s auxiliary power port Presentation Mode Out of Stand When the scanner is not in the stand it automatically detects bar codes then scans and transmits the data The laser turns off ...

Page 100: ... Good Read is enabled the laser turns off and stops scanning after a good read If you scan Do Not End Manual Activation After Good Read the laser remains on after a good read but the button must be pressed to scan the next bar code Default End Manual Activation After Good Read Manual Activation Mode On In Stand Manual Activation Mode Off In Stand Manual Activation Mode On Out of Stand Manual Activ...

Page 101: ...nds for a timeout by scanning one of the following bar codes then setting the timeout from 1 65535 millisec onds by scanning digits from the Programming Chart then scanning Save Default Button Hold In Stand 5000 ms Button Hold Out of Stand 5000 ms Button Release In or Out of Stand 0 Laser Timeout Button Release In Stand Laser Timeout Button Hold In Stand Laser Timeout Button Release Out of Stand L...

Page 102: ...ff in Stand CodeGate On Out of Stand Object Detection Mode Object Detection Mode uses an LED to detect when an object is in the scanner s field of view When an object is detected the laser turns on and the scanner attempts to scan the bar code Default Object Detection Mode On In Stand CodeGate On In Stand CodeGate Off In Stand CodeGate On Out of Stand CodeGate Off Out of Stand Object Detection Mod...

Page 103: ...tion Laser Timeout You can set a timeout for the length of time the laser remains on and attempting to decode bar codes after an object is detected Set the length in milliseconds for a timeout by scanning the following bar code then set ting the timeout from 1 65535 milliseconds by scanning digits from the Programming Chart then scanning Save Default 5000 ms End Object Detection After Good Read In...

Page 104: ... is received the scanner continues scanning until either the Character Activation Laser Timeout page 4 15 the deactivation character is received see Deactivation Character on page 4 16 or a bar code is transmitted Scan the following On bar code to use character activation then use Activation Character following to select the character you will send from the host to start scanning Default Off Activ...

Page 105: ...f you scan Do Not End Character Activation After Good Read the laser remains on after a good read Default End Character Activation After Good Read Character Activation Laser Timeout You can set a timeout for the length of time the laser remains on and attempting to decode bar codes when using Character Activation Mode Set the length in milliseconds for a timeout by scanning the following bar code ...

Page 106: ...ter you will send from the host to termi nate scanning Default Off Deactivation Character This sets the character used to terminate scanning when using Character Deactivation Mode On the ASCII Conversion Chart Code Page 1252 page A 4 find the hex value that represents the character you want to use to terminate scanning Scan the following bar code then use the Programming Chart to read the alphanum...

Page 107: ...r own length for the reread delay scan the following bar code then set the delay from 0 30 000 milliseconds by scanning digits from the Programming Chart then scanning Save Output Sequence Overview Require Output Sequence When turned off the bar code data will be output to the host as the scanner decodes it When turned on all output data must conform to an edited sequence or the scanner will not t...

Page 108: ...age A 1 find the symbology to which you want to apply the output sequence format Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside back cover 3 Length Specify what length up to 9999 characters of data output will be acceptable for this symbology Scan the four digit data length from the Programming Chart Note 50 characters is entered as 0050 99...

Page 109: ...ation string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128 9999 all lengths 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 9999 code length that must match for Code 93 9999 all lengths 43 start character match for Code 93 43h C FF termination string for third code To program the previou...

Page 110: ... 93 0012 C Code 93 sample length 11 plus CR suffix 1 12 43 start character match for Code 93 43h C FF termination string for third code Output Sequence Editor Sequence Timeout You may wish to set the maximum time between bar code scans in an out put sequence If that maximum time is not met the output sequence oper ation is terminated Set the length in milliseconds for a timeout by scanning the fol...

Page 111: ...equence to transmit partial sequences Any fields in the sequence where no data match occurred will be skipped in the output If you have programmed a Sequence Timeout page 4 20 and the timeout is reached the partial sequence is transmitted Default Dis card Partial Sequence Require Output Sequence When an output sequence is Required all output data must conform to an edited sequence or the scanner w...

Page 112: ...read If using an EZConfig Scanning Tool Scan Data Window see page 9 2 an NR appears when a code cannot be read If No Read is turned Off the NR will not appear Default Off If you want a different notation than NR for example Error or Bad Code you can edit the output message see Data Formatting beginning on page 6 1 The hex code for the No Read symbol is 9C Required On Not Required Off On Off ...

Page 113: ...x is dependent on interface A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 beginning on page A 4 plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in which you want them to appear on the output...

Page 114: ...thout saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for U P C only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart included in the Symbology Chart beginning on page A 1 for U P C Step 3 Scan 6 3 from the Programming Chart inside the back cover of this ma...

Page 115: ...e from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then pro grams a carriage return suffix for all symbologies Prefix Sele...

Page 116: ...n the corresponding Keyboard Function output Example Transmit Alternate Extended ASCII is enabled and you scan Add Suffix then scan 9 9 8 9 All symbologies 99 would have a suffix of a Page Down hex 89 added to them When Transmit Normal Extended ASCII is selected the normal extended ASCII character is transmitted see ASCII Conversion Chart Code Page 1252 on page A 4 Example Transmit Normal Extended...

Page 117: ...ck 136 88 Page Up 160 A0 Num Lock 137 89 Page Down 161 A1 Left Alt 138 8A Right ALT 162 A2 Left Ctrl 139 8B Right CTRL 163 A3 Left Shift 140 8C Reserved 164 A4 Right Shift 141 8D Reserved 165 A5 Print Screen 142 8E Numeric Keypad Enter 166 A6 Tab 143 8F Numeric Keypad 167 A7 Shift Tab 144 90 F1 168 A8 Enter 145 91 F2 169 A9 Esc 146 92 F3 170 AA Alt Make 147 93 F4 171 AB Alt Break 148 94 F5 172 AC ...

Page 118: ...eck Character To enhance security you can specify the transmission type of a check charac ter either LRC where the calculation starts on the first transmitted character LRC where the calculation starts on the second transmitted character or CRC Note This option adds a check character to the bar code data for all symbologies If you need to enable or disable check characters for individual symbologi...

Page 119: ...ramming Chart inside the back cover of this manual To remove this delay scan the Intercharacter Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Note Intercharacter delays are not supported in USB serial emulation User Specified Intercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms inc...

Page 120: ...f up to 5000 milliseconds in 5ms increments may be placed between the transmission of each segment of the message string Scan the following Interfunction Delay bar code then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Interfunction Delay bar code then set the number of delays to 0 Scan the Save b...

Page 121: ...then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intermessage Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual 2nd Scan Transmission 1st Scan Transmission Intermessage Delay Intermessage Delay ...

Page 122: ...5 10 ...

Page 123: ...D Universal Code ID Actual Length 4 Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Length 6 Universal Terminal ID Actual Code ID Universal Length 7 Universal Terminal ID Universal Code ID Actual Length 8 Universal Terminal ID Universal Code ID Universal Length The maximum size of a data format configuration is 256 bytes which includes header i...

Page 124: ... format Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual Step 5 Length Specify what length up to 9999 characters of data will be acceptable for this symbology Scan the four digit data length from the Programming Chart inside the back cover of this manual Note 50 characters is entered as 0050 9999 is a universal n...

Page 125: ... scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Chart on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Clear all Data Formats This clears all data formats Save to exit and save your data format changes Discard to exit without saving any data format changes Clea...

Page 126: ... insert character Start from the current cursor position and continue for nn characters or through the last character in the input message followed by character xx Syntax F2nnxx where nn stands for the numeric value 00 99 for the number of characters and xx stands for the insert character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 on page A 4 for decimal hex ...

Page 127: ...he cursor in the current position Syntax F4xxnn where xx stands for the insert character s hex value for its ASCII code and nn is the numeric value 00 99 for the number of times it should be sent Refer to the ASCII Conversion Chart Code Page 1252 on page A 4 for decimal hex and character codes Insert symbology name B3 Insert the name of the bar code s symbology in the output message without moving...

Page 128: ...fer to the ASCII Conversion Chart Code Page 1252 on page A 4 for decimal hex and character codes Search forward for a string B0 Search forward for s string from the current cursor position leaving cursor pointing to s string Syntax B0nnnnS where nnnn is the string length up to 9999 and S consists of the ASCII hex value of each character in the match string For example B0000454657374 will search fo...

Page 129: ...acters FB Suppress all occurrences of up to 15 different characters starting at the current cursor position as the cursor is advanced by other commands When the FC command is encountered the suppress function is terminated The cursor is not moved by the FB command Syntax FBnnxxyy zz where nn is a count of the number of suppressed characters in the list and xxyy zz is the list of characters to be s...

Page 130: ...cter codes Check for a number EC Check to make sure there is an ASCII number at the current cursor position The format is aborted if the character is not numeric Check for non numeric character ED Check to make sure there is a non numeric ASCII character at the current cursor position The format is aborted if the character is numeric Insert a delay EF Inserts a delay of up to 49 995 milliseconds i...

Page 131: ...particular symbol those prefixes and suffixes are not transmitted Any data that does not match your data format requirements generates an error tone If you wish to process this type of bar code without generating an error tone see Data Format Non Match Error Tone Choose one of the following options Default Data Formatter On Not Required Keep Prefix Suffix Data Format Non Match Error Tone When a ba...

Page 132: ...t is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the fol lowing bar codes Single Scan Data Format Change You can also switch between data formats for a single scan The next bar code is scanned using an alternate data format then reverts to the format you have selected above either Primary 1 2 or 3 Data Format Non Match...

Page 133: ...tch to Data Format 1 for a single button press by scanning the following Single Scan Data Format 1 bar code The next bar code that is scanned uses Data Format 1 then reverts back to Data Format 3 Single Scan Data Format 1 Single Scan Data Format 2 Single Scan Data Format 3 Single Scan Primary Data Format ...

Page 134: ...6 12 ...

Page 135: ...lar symbology All Symbologies GS1 128 Airline Code 5 see Straight 2 of 5 IATA two bar start stop Interleaved 2 of 5 China Post Hong Kong 2 of 5 ISBT 128 Codabar Matrix 2 of 5 Code 11 MSI Code 128 NEC 2 of 5 Code 32 Pharmaceutical PARAF Plessey Code Code 39 Postal Codes Code 93 Straight 2 of 5 IATA two bar start stop EAN JAN 13 Straight 2 of 5 Industrial three bar start stop EAN JAN 8 Telepen GS1 D...

Page 136: ...e the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15Max length 15 For a value other than the minimum and maximum message length defaults scan the bar codes included in the explanation of the symbology then scan the digit value of the message length an...

Page 137: ...ated using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 Mod ulo 7 CD or CLSI check characters Default No Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar bar codes printed with a check...

Page 138: ... enable concatena tion the scanner looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two mes sages are concatenated into one with the D characters omitted No Check Character Validate Modulo 16 and Transmit Validate Modulo 16 but Don t Transmit Validate Modulo 7 CD but Don t Transmit Validate CLSI but Don t Transmit Validate Modulo...

Page 139: ...s from the Programming Chart then scanning Save Default 750 Codabar Redundancy If you are encountering errors when reading Codabar bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adju...

Page 140: ...following bar codes to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 3 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Page 141: ...Start Stop characters Default Don t Transmit Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data On Off Transmit Don t Tra...

Page 142: ...rors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the Code 39 Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the Save bar code Default 0 Code 39 Message Length Scan the bar codes below to change the message length Refer to Messag...

Page 143: ... C will be decoded as the ASCII character Default Off NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X H 8 8 H H X X h H x X HT I EM Y I 9 9 I I Y Y i I y Y LF J S...

Page 144: ...7 10 Character pairs M and N decode as a minus sign and period respectively Character pairs P through Y decode as 0 through 9 Full ASCII Off Full ASCII On ...

Page 145: ...tt Formatting NULL Characters Interleaved 2 of 5 requires an even number of characters When an odd number of characters is present it is due to NULL characters embedded in the bar code Scan the On bar code below to decode this type of Inter leaved 2 of 5 bar code Default Off On Off Off On Off On ...

Page 146: ...ta Default No Check Digit Interleaved 2 of 5 Redundancy If you are encountering errors when reading Interleaved 2 of 5 bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redun...

Page 147: ... Default 80 NEC 2 of 5 Default All NEC 2 of 5 Settings NEC 2 of 5 On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit When Check Digit is set to Validate but Don t Transmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data Minimum Message Length Max...

Page 148: ...ote that the higher the redundancy count the lon ger it will take to decode the bar code To adjust the redundancy scan the NEC 2 of 5 Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the Save bar code Default 0 NEC 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Messa...

Page 149: ... times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the Code 93 Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the Save bar code Default 0 On Off Cod...

Page 150: ... 5 Industrial On Off Straight 2 of 5 Industrial Redundancy If you are encountering errors when reading Straight 2 of 5 Industrial bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjus...

Page 151: ...de Default 0 Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 3 Maximum Default 80 Straight 2 of 5 Industrial Redundancy Minimum Message Length Maximum Message Length ...

Page 152: ...t the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the Straight 2 of 5 IATA Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back c...

Page 153: ...5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 On Off Matrix 2 of 5 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Matrix 2 of 5 bar codes printed with a check character but will not transmit the check character with the scanned data ...

Page 154: ...rrors Note that the higher the redundancy count the lon ger it will take to decode the bar code To adjust the redundancy scan the Matrix 2 of 5 Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the Save bar code Default 0 Matrix 2 of 5 Message Length Scan the bar codes below to change the message length R...

Page 155: ...er of check digits based on the length of the bar code If the bar code is 10 digits or more 2 check digits are required If it is 9 digits or less 1 check digit is required The check digit data is only transmitted if you program that fea ture see Check Digit Validation on page 7 22 Default Two Check Digits Required On Off One Check Digit Required Two Check Digits Required Auto Select Check Digits R...

Page 156: ...t Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the Code 11 Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the ...

Page 157: ...he bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 3 Maximum Default 80 Minimum Message Length Maximum Message Length ...

Page 158: ...he group separator is not output Default Off Code 128 Redundancy If you are encountering errors when reading Code 128 bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redund...

Page 159: ...change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 3 Maximum Default 80 ISBT 128 ISBT is a variation of Code 128 that supports concatenation of neighboring symbols on a blood product label Use the bar codes below to turn ISBT 128 concatenation on or off Default Off Code 128 Redundancy Minimum Message L...

Page 160: ... following bar codes are used to select the pre defined ISBT 128 Con catenation Sequence you wish to use Once you have selected the concat enation sequence use ISBT 128 Predefined Concatenation Sequences On Off to enable this feature Default Donation ID Number 001 and ABO RhD Blood Groups 002 Concatenation Timeout Donation ID Number 001 and ABO RhD Blood Groups 002 Product Code 003 and Expiration ...

Page 161: ...to create a custom ISBT 128 Concatena tion Sequence Select the identifiers you want to transmit in the 1st and 2nd positions both left and right Refer to the ISBT 128 Standard Technical Specification for the list of data identifiers Use the ASCII Conversion Chart Code Page 1252 beginning on page A 4 to find the characters needed for the identifier Locate the hex value for each character and scan t...

Page 162: ...rt to scan 3 C hex for Step 12 Scan Save Once you have programmed the concatenation sequence use ISBT 128 User Defined Concatenation Sequences to enable this feature Default 0 ISBT 128 User Defined Concatenation Sequences On Off The following selections allow you to enable or require the User Defined ISBT 128 Concatenation Sequences If you scan Off the User Defined concatenation sequences are disa...

Page 163: ...he bar code data thus allowing you to verify that the check character is in agreement with that calculated for the data stream Default Off Transmit Identifiers You may disable the transmission of the ISBT Code 128 data identifiers by scanning Off When this selection is Off the first 2 data ID characters are removed from the data stream unless the ISBT code contains the Donation Identification Numb...

Page 164: ...tted as normal data Default On Flag Digit Conversion Type 3 flag digits are a part of the Donation Identification Number in an ISBT 128 bar code If you select On the flag data is converted into a sin gle MOD 37 2 character and transmitted with the bar code data Scan Off if you do not want the flag digits transmitted Default Off Off On Off On ...

Page 165: ...s and stripped of the AI If you want the AI included scan Transmit With Identifiers Default Off GS1 128 Redundancy If you are encountering errors when reading GS1 128 bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will...

Page 166: ...his manual Then scan the Save bar code Default 0 GS1 128 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 3 Maximum Default 80 GS1 128 Redundancy Minimum Message Length Maximum Message Length ...

Page 167: ... them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Redundancy If you are encountering errors when reading Telepen bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it...

Page 168: ... this manual Then scan the Save bar code Default 0 Telepen Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 3 Maximum Default 80 Telepen Redundancy Minimum Message Length Maximum Message Length ...

Page 169: ...it UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the can be programmed so it will not transmit it Default On On Off Check Digit Number System UPC A sample showing the number system and check digit Off On ...

Page 170: ...5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda UPC A Addenda Required When Required is scanned the scanner will only read UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda listed on page 7 36 Default Not Required On Off 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Page 171: ...PC A Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default Off UPC A Redundancy If you are encountering errors when reading UPC A bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the nu...

Page 172: ...e data No data is output unless both codes are read Default Off UPC A Number System 4 Addenda Required This setting programs the scanner to require a coupon code only on UPC A bar codes that begin with a 4 The following settings can be programmed Require Coupon Code All UPC A bar codes that begin with a 4 must have a coupon code The UPC A bar code with the coupon code is then transmitted as a sing...

Page 173: ...git addenda or a combination of these addenda The UPC A bar code with the coupon code and or addenda is then transmitted as a single concatenated bar code If a coupon code and or required addenda is not found within the Addenda Timeout period the UPC A bar code is discarded Don t Require Coupon Code Addenda If you have selected Require Coupon Code Addenda and you want to disable this feature scan ...

Page 174: ...based on the setting you are using for UPC A EAN 13 with Extended Coupon Code or UPC A Number System 4 Addenda Required Set the length in milliseconds for this timeout by Require 2 Digit Addenda Don t Require Coupon Code Addenda Require 5 Digit Addenda Require 2 or 5 Digit Addenda Require Coupon Code Require Coupon Code or 2 Digit Addenda Require Coupon Code or 5 Digit Addenda Require Coupon Code ...

Page 175: ... addenda and coupon code searches UPC E0 Default All UPC E0 Settings UPC E0 On Off Most U P C bar codes lead with the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number system use EAN JAN 13 page 7 45 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off Addenda Timeout UPC E0 On UPC ...

Page 176: ...E Expand the unit can be programmed so it will not transmit it Default On UPC E0 Number System and Check Digit UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default Off Off On Check Digit Number System UPC E0 sample showing the number system and check digit Off On ...

Page 177: ...0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda UPC E0 Addenda Required When Required is scanned the scanner will only read UPC E bar codes that have addenda Default Not Required Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Page 178: ...0 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default Off UPC E0 Redundancy If you are encountering errors when reading UPC E0 bar codes you may want to adjust the redundancy count Redundancy adjusts the number of times a bar code is decoded before transmission which may reduce the num...

Page 179: ... Default All EAN JAN Settings EAN JAN 13 On Off EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off Off On ...

Page 180: ...on EAN 13 bar codes that begin with a 2 The following settings can be pro grammed Require 2 Digit Addenda All EAN 13 bar codes that begin with a 2 must have a 2 digit addendum The EAN 13 bar code with the 2 digit addendum is then transmitted as a single concatenated bar code If a 2 digit addendum is not found within the Addenda Timeout period the EAN 13 bar code is discarded Note if you are using ...

Page 181: ...catenated bar code If a 5 digit addendum is not found within the Addenda Timeout period the EAN 13 bar code is discarded Note if you are using EAN 13 Beginning with 2 Addenda Required page 7 46 this setting will take precedence Don t Require 5 Digit Addenda If you have selected Require 5 Digit Addenda and you want to disable this feature scan Don t Require 5 Digit Addenda EAN 13 bar codes are tran...

Page 182: ... setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN 13 bar codes that begin with a 414 or 419 The following settings can be programmed Require Addenda All EAN 13 bar codes that begin with a 414 or 419 must have a 2 digit addenda a 5 digit addenda or a combination of these addenda The EAN 13 bar code with the addenda is then transmitted as a sin...

Page 183: ... 5 digit addenda or a combination of these addenda The EAN 13 bar code with the addenda is then transmitted as a single concatenated bar code If the required addenda is not found within the Addenda Timeout period the EAN 13 bar code is discarded Don t Require Addenda If you have selected Require Addenda and you want to disable this feature scan Don t Require Addenda EAN 13 bar codes are transmitte...

Page 184: ...eout period the EAN 13 bar code is discarded Don t Require 2 Digit Addenda If you have selected Require 2 Digit Addenda and you want to disable this feature scan Don t Require 2 Digit Addenda EAN 13 bar codes are transmitted depending on the setting you are using for EAN JAN 13 Addenda Required Default Don t Require 2 Digit Addenda EAN 13 Beginning with 978 Addenda Required These settings program ...

Page 185: ...e settings program the scanner to require a 5 digit addenda only on EAN 13 bar codes that begin with 979 The following settings can be pro grammed Require 5 Digit Addenda All EAN 13 bar codes that begin with 979 must have a 5 digit addendum The EAN 13 bar code with the 5 digit addendum is then transmitted as a single concatenated bar code If a 5 digit addendum is not found within the Addenda Timeo...

Page 186: ...data from the bar code and the data from the addenda When turned Off there is no space Default Off Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 7 38 EAN JAN 13 Redundancy If you are encountering errors when reading EAN JAN 13 bar codes you may want to adjust the redundancy count Redundancy adjusts the num ber of times a ...

Page 187: ...u can convert the bar code to a 13 digit format by scanning the Convert to 13 Digit On bar code below Default Convert to 13 Digit Off ISBN Reformat In normal use the first two or three digits of an EAN 13 bar code iden tify the country of origin The country prefixes are 978 and 979 To reformat ISBN codes so the country prefix is dropped out scan the Reformat On bar code below Default Reformat Off ...

Page 188: ...tted as 01234560 Default Off ISSN Reformat When Reformat On is scanned EAN 13 977 Bookland symbols are translated into their equivalent 8 digit ISSN number format with hyphens added to the output For example 9770123456787 will be transmitted as 0123 456 0 You must first scan ISSN On page 7 54 before scanning Reformat On Default Reformat Off Off On Reformat On Reformat Off ...

Page 189: ... Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off Off On ...

Page 190: ...codes that have addenda Default Not Required Addenda Timeout You can set a time during which the scanner looks for an addenda If an addenda is not found within this time period the data can be either trans mitted or discarded based on the setting you are using for EAN JAN 8 Addenda Required Set the length in milliseconds for this timeout by 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Of...

Page 191: ...ce Default Off EAN JAN 8 Redundancy If you are encountering errors when reading EAN JAN 8 bar codes you may want to adjust the redundancy count Redundancy adjusts the num ber of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the lon ger it will take to decode the ba code To adjust the redundancy scan the EAN JAN 8 Red...

Page 192: ...ogram the scanner to read MSI bar codes with Type 10 check charac ters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate Type 10 and Transmit the scan ner will only read MSI bar codes printed with the specified type check char acter s and will transmit the character s at the end of the scanned data On Off ...

Page 193: ...s a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the MSI Redun dancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the Save bar code Default 0 Validate Type 10 a...

Page 194: ...Default All Plessey Code Settings Plessey Code On Off Plessey Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Plessey bar codes printed with a check character but will not transmit the check character with the scanned data Minimum Message ...

Page 195: ...rrors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the Plessey Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the Save bar code Default 0 Plessey Message Length Scan the bar codes below to change the message length Refer to Messa...

Page 196: ...dundancy adjusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redun dancy count the longer it will take to decode the bar code To adjust the redundancy scan the GS1 DataBar Omnidirectional Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manu...

Page 197: ...usts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the GS1 DataBar Limited Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the Save...

Page 198: ...djusts the number of times a bar code is decoded before transmission which may reduce the number of errors Note that the higher the redundancy count the longer it will take to decode the bar code To adjust the redundancy scan the GS1 DataBar Expanded Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual Then scan the S...

Page 199: ...ca tion that accepts GS1 data can be simplified since it only needs to recognize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Chart on page A 1 If GS1 DataBar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16...

Page 200: ...n Off Postal Codes The following lists linear postal codes Any combination of linear postal code selections can be active at a time China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings GS1 DataBar Emulation GS1 128 Emulation GS1 Emulation Off GS1 Code Expansion Off EAN8 to EAN13 Conversion ...

Page 201: ...e to decode the bar code To adjust the redundancy scan the China Post Hong Kong 2 of 5 Redundancy bar code below then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this man ual Then scan the Save bar code Default 0 China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 ...

Page 202: ...7 68 ...

Page 203: ...used with the scanner Refer to page 2 17 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E US 1F _ ...

Page 204: ...9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ASCII HEX IBM AT XT and PS 2 Compatibles WYSE PC AT Supported Keys Apple Mac iMac Supported Keys NUL 00 Reserved Reserved SOH 01 Enter KP Enter Numpad Enter STX 02 Cap Lock CAPS ETX 03 ALT make ALT make EOT 04 ALT break ALT break ENQ 05 CTRL make CNTRL make ACK 06 CTRL break CNTRL break BEL 07 CR E...

Page 205: ... Scrn DC3 13 Back Space BACKSPACE DC4 14 Back Tab LSHIFT TAB NAK 15 F12 F12 SYN 16 F1 F1 ETB 17 F2 F2 CAN 18 F3 F3 EM 19 F4 F4 SUB 1A F5 F5 ESC 1B F6 F6 FS 1C F7 F7 GS 1D F8 F8 RS 1E F9 F9 US 1F F10 F10 DEL 7F BACKSPACE ASCII HEX IBM AT XT and PS 2 Compatibles WYSE PC AT Supported Keys Apple Mac iMac Supported Keys ...

Page 206: ...8 4 ...

Page 207: ...s all current prefixes then programs a Code I D prefix for all symbologies This is a temporary setting that will be removed when the unit is power cycled Show Software Revision Scan the bar code below to output the current software revision unit serial num ber and other product information for both the scanner and base Show Data Format Scan the bar code below to show current data format settings A...

Page 208: ...arameters and mail or fax that bar code to any location Users in other locations can scan the bar code to load in the customized programming To communicate with a scanner EZConfig Scanning requires that the PC have at least one available serial communication port or a serial port emulation using a physical USB port If you are using the serial port and RS232 cable an exter nal power supply is requi...

Page 209: ... to install it during the EZConfig Scanning installation 1 Access the Honeywell web site at www honeywellaidc com 2 Click on the Downloads tab Select Software 3 Click on the dropdown for Select Product Number and select the number of your product 4 Click on the listing for EZConfig Scanning 5 Follow the security directions as prompted on the screen 6 When prompted select Save and save the file to ...

Page 210: ...9 4 ...

Page 211: ...ear on the screen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Name Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Name To send information to the scanner with the base connected to host use Voyager The default factory setting for a Voyager scanner is Voyager scanner If the name ...

Page 212: ...d the query applies to the entire set of commands available for the particular storage table indicated by the Storage field of the command In this case the SubTag and Data fields should not be used because they are ignored by the device SubTag Field Usage When a query is used in place of a SubTag field the query applies only to the subset of commands available that match the Tag field In this case...

Page 213: ... Query Commands In the following examples a bracketed notation depicts a non displayable response Example What is the range of possible values for Codabar Coding Enable Enter cbrena Response CBRENA0 1 ACK This response indicates that Codabar Coding Enable CBRENA has a range of values from 0 to 1 off and on Example What is the default value for Codabar Coding Enable Enter cbrena Response CBRENA1 AC...

Page 214: ...ctivate com mand is sent The scanner can also be set to turn itself off after a specified time has elapsed see Read Time Out which follows Read Time Out Use this selection to set a time out in milliseconds of the scanner s button when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scanner either by pressing the button or using a serial trigger comm...

Page 215: ...10 5 The charts on the following pages list the factory default settings for each of the commands indicated by an asterisk on the programming pages ...

Page 216: ...gramming the Interface Plug and Play Codes Keyboard Wedge IBM PC AT and Compatibles with CR suffix PAP_AT 2 1 IBM PS2 Keyboard PAPPS2 2 1 RS232 Serial Port PAP232 2 2 Plug and Play Codes RS485 IBM Port 5B Interface PAPP5B 2 2 IBM Port 9B HHBCR 1 Interface PAP9B1 2 2 IBM Port 17 Interface PAPP17 2 2 IBM Port 9B HHBCR 2 Interface PAP9B2 2 2 OPOS Mode OPOS Mode PAPOPS 2 3 Plug and Play Codes IBM Sure...

Page 217: ...C PAP124 2 5 USB Keyboard Mac PAP125 2 5 USB Japanese Keyboard PC PAP134 2 5 USB HID PAP131 2 5 HID Fallback Mode HID Fallback Mode Range 0 60 5 minutes USBFTO 2 6 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 218: ...USBCTS0 2 6 ACK NAK Mode On USBACK1 2 7 ACK NAK Mode Off USBACK0 2 7 Communication Timeout Range 0 65535 2000 ms 232DLK 2 7 Timeout Retries HSTRTY 2 7 Communication Timeout Beeper Off HSTTOA0 2 8 Communication Timeout Beeper On HSTTOA1 2 8 NAK Retries Range 0 255 0 HSTRTN 2 8 BEL CAN Mode On BELCAN1 2 8 BEL CAN Mode Off BELCAN0 2 8 Selection Setting Indicates default Serial Command Indicates a num...

Page 219: ...PGLB 2 9 Honeywell Bioptic Aux Port PAPBIO 2 10 Datalogic Magellan Bioptic Aux Port PAPMAG 2 10 NCR Bioptic Aux Port PAPNCR 2 10 Wincor Nixdorf Terminal PAPWNX 2 11 Wincor Nixdorf Beetle PAPBTL 2 12 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 220: ... Slovenia KBDCTY31 2 14 Spain KBDCTY10 2 14 Switzerland German KBDCTY6 2 14 Thailand KBDCTY94 2 14 Turkey Q KBDCTY24 2 14 United Kingdom KBDCTY7 2 14 Vietnam KBDCTY95 2 14 Keyboard Wedge Modifiers ALT Mode Off KBDALT0 2 15 3 Characters KBDALT6 2 15 4 Characters KBDALT7 2 15 Keyboard Style Regular KBDSTY0 2 15 Caps Lock KBDSTY1 2 15 Shift Lock KBDSTY2 2 15 Autocaps via NumLock KBDSTY7 2 16 Emulate ...

Page 221: ...de Control ASCII KBDCAS2 2 17 Windows Mode Prefix Suffix Off KBDCAS3 2 17 Numeric Keypad Off KBDNPS0 2 17 Numeric Keypad On KBDNPS1 2 17 Inter Scan Code Delay Inter Scan Code Delay 0 Range 1 30 msecs KBDDLY 2 18 F0 Break Character Suppress F0 Break Character KBDF0B0 2 18 Transmit F0 Break Character KBDF0B1 2 18 Keyboard Wedge Defaults Reset Keyboard Wedge Defaults KBDDFT 2 18 Selection Setting Ind...

Page 222: ...BAD1 2 19 1200 BPS 232BAD2 2 19 2400 BPS 232BAD3 2 19 4800 BPS 232BAD4 2 19 9600 BPS 232BAD5 2 19 19200 BPS 232BAD6 2 19 38400 BPS 232BAD7 2 19 57600 BPS 232BAD8 2 19 115200 BPS 232BAD9 2 19 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 223: ...rity Odd 232WRD7 2 20 8 Data 1 Stop Parity Even 232WRD5 2 20 8 Data 1 Stop Parity None 232WRD2 2 20 8 Data 1 Stop Parity Odd 232WRD8 2 20 7 Data 1 Stop Parity Space 232WRD9 2 20 7 Data 2 Stop Parity Space 232WRD10 2 21 8 Data 1 Stop Parity Space 232WRD11 2 21 7 Data 1 Stop Parity Mark 232WRD12 2 21 7 Data 2 Stop Parity Mark 232WRD13 2 21 8 Data 1 Stop Parity Mark 232WRD14 2 21 Selection Setting In...

Page 224: ... RTS CTS Off RTS Inactive 232CTS10 2 22 RS232 Timeout Range 1 5100 1000 ms 232DEL 2 22 XON XOFF Off 232XON0 2 23 XON XOFF On 232XON1 2 23 ACK NAK Off 232ACK0 2 23 ACK NAK On 232ACK1 2 23 Communication Timeout Range 1 65535 2000 ms 232DLK 2 23 Communication Timeout Beeper Off HSTTOA0 2 24 Communication Timeout Beeper On HSTTOA1 2 24 BEL CAN Mode On BELCAN1 2 25 BEL CAN Mode Off BELCAN0 2 25 Selecti...

Page 225: ...AZ0 2 27 Scanner to Bioptic Communication Packet Mode Off 232PKT0 2 28 Packet Mode On 232PKT2 2 28 ACK NAK Off 232ACK0 2 28 ACK NAK On 232ACK1 2 28 Communication Timeout Range 1 65535 2000 ms 232DLK 2 28 Cordless System Operation Note This section applies only to cordless systems It does not apply to corded scanners Base Power Communication Indicator On BASRED1 3 7 Off BASRED0 3 7 Reset Scanner Re...

Page 226: ...N1 3 11 Unlink Scanner BT_RMV 3 11 Override Locked Scanner BT_RPL1 3 12 Out of Range Alarm Alarm Off BT_ORW0 3 12 Alarm On BT_ORW1 3 12 Scanner Alarm Duration Range 1 3000 sec 1 BT_ORD 3 12 Scanner Power Time Out Timer Timer Off BT_LPT0 3 13 200 Seconds BT_LPT200 3 13 400 Seconds BT_LPT400 3 13 900 Seconds BT_LPT900 3 13 3600 Seconds BT_LPT3600 3 13 7200 Seconds BT_LPT7200 3 13 Batch Mode Automati...

Page 227: ...Counter On BATENT1 3 17 Total Records Total Records BATNRC 3 17 Batch Mode Output Order FIFO BATLIF0 3 18 LIFO BATLIF1 3 18 Clear All Codes After Transmission Don t Clear All Codes After Transmission BATCLX0 3 18 Clear All Codes After Transmission BATCLX1 3 18 Clear All Codes Clear All Codes BATCLR 3 18 Transmit Records Automatically Don t Transmit Records Automatically BATATX0 3 19 Transmit Recor...

Page 228: ...Link Attempts Maximum Link Attempts Range 0 255 0 BT_MLA 3 24 Relink Time Out Relink Time Out Range 0 100 3 BT_RLT 3 24 Reset Reset Base RESET_ 3 25 Reset Scanner RESET_ 3 25 Input Output Selections Power Up Beeper Power Up Beeper Off Scanner BEPPWR0 4 1 Power Up Beeper On Scanner BEPPWR1 4 1 Beep on BEL Character Beep on BEL On BELBEP1 4 1 Beep on BEL Off BELBEP0 4 1 Beeper Good Read Off BEPBEP0 ...

Page 229: ...Transmission BEPWHN2 4 3 Beeper Pitch Error Frequency Razz 100 Hz BEPFQ2100 4 3 Medium 2000 Hz BEPFQ22000 4 3 High 4200 Hz BEPFQ24200 4 3 Beeper Duration Good Read Normal Beep BEPBIP0 4 4 Short Beep BEPBIP1 4 4 Number of Beeps Good Read Range 1 9 1 BEPRPT 4 4 Number of Beeps Error Range 1 9 1 BEPERR 4 5 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 230: ...FN22 4 6 Red LED On when CodeGate Disabled LEDFN14 4 6 Green LED On when CodeGate Disabled LEDFN24 4 6 Red LED On when In Stand LEDFN18 4 6 Green LED On when In Stand LEDFN28 4 6 Red LED On with CTS LEDFN1128 4 7 Green LED On with CTS LEDFN2128 4 7 Red LED when Battery is Low LEDFN11024 Green LED when Battery is Low LEDFN21024 Selection Setting Indicates default Serial Command Indicates a numeric ...

Page 231: ... 8 Green Off LEDIN20 4 8 Red Low LEDIN11 4 8 Green Low LEDIN21 4 8 Red Medium LEDIN12 4 8 Green Medium LEDIN22 4 8 Red High LEDIN13 4 8 Green High LEDIN23 4 8 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 232: ...tivation Mode Off Out of Stand AOSMEN0 4 10 Manual Activation Mode On Out of Stand AOSMEN1 4 10 Do Not End Manual Activation After Good Read In Stand AISMGD0 4 10 End Manual Activation After Good Read In Stand AISMGD1 4 10 Do Not End Manual Activation After Good Read Out of Stand AOSMGD0 4 10 End Manual Activation After Good Read Out of Stand AOSMGD1 4 10 Laser Timeout Button Hold In Stand Range 1...

Page 233: ... In Stand AISCGD0 4 12 CodeGate On In Stand AISCGD1 4 12 CodeGate Off Out of Stand AOSCGD0 4 12 CodeGate On Out of Stand AOSCGD1 4 12 Object Detection Mode Off In Stand AISOEN0 4 12 Object Detection Mode On Out of Stand AOSOEN1 4 12 Object Detection Mode Off Out of Stand AOSOEN0 4 12 Object Detection Mode On In Stand AISOEN1 4 12 Do Not End Object Detection After Good Read In Stand AISOGD0 4 13 Se...

Page 234: ...t Detection Laser Timeout In Stand Range 1 65525 5000 ms AISODT 4 13 Object Detection Laser Timeout Out of Stand Range 1 65525 5000 ms AOSODT 4 13 Object Detection Distance Short In Stand AISRNG2 4 14 Object Detection Distance Long In Stand AISRNG1 4 14 Object Detection Distance Short Out of Stand AOSRNG2 4 14 Object Detection Distance Long Out of Stand AOSRNG1 4 14 Selection Setting Indicates def...

Page 235: ...r HSTDCH 4 16 Reread Delay Short 500 ms DLYRRD500 4 17 Medium 750 ms DLYRRD750 4 17 Long 1000 ms DLYRRD1000 4 17 Extra Long 2000 ms DLYRRD2000 4 17 User Specified Reread Delay Range 0 30 000 ms DLYRRD 4 17 Output Sequence Editor Enter Sequence SEQBLK 4 20 Default Sequence SEQDFT 4 20 Sequence Timeout Range 1 65535 5000 ms SEQDLY 4 20 Sequence Match Beeper On SEQBEP1 4 21 Off SEQBEP0 4 21 Partial S...

Page 236: ... Alternate Extended ASCII Characters Transmit Alternate Extended ASCIi KBDEXT0 5 4 Transmit Normal Extended ASCIi KBDEXT1 5 4 Function Code Transmit Enable RMVFNC0 5 6 Disable RMVFNC1 5 6 Communication Check Character None HSTXRC0 5 6 LRC Starts on 1st Character HSTXRC1 5 6 LRC Starts on 2nd Character HSTXRC2 5 6 CRC HSTXRC3 5 6 Intercharacter Delay Range 0 1000 5ms increments DLYCHR 5 7 User Spec...

Page 237: ...A3 6 3 Data Formatter Data Formatter Off DFM_EN0 6 8 Data Formatter On Not Required Keep Prefix Suffix DFM_EN1 6 9 Data Format Required Keep Prefix Suffix DFM_EN2 6 9 Data Formatter On Not Required Drop Prefix Suffix DFM_EN3 6 9 Data Format Required Drop Prefix Suffix DFM_EN4 6 9 Data Format Non Match Error Tone Data Format Non Match Error Tone On DFMDEC0 6 10 Data Format Non Match Error Tone Off ...

Page 238: ...e Scan Data Format 1 VSAF_1 6 11 Single Scan Data Format 2 VSAF_2 6 11 Single Scan Data Format 3 VSAF_3 6 11 Symbologies All Symbologies All Symbologies Off ALLENA0 7 1 All Symbologies On ALLENA1 7 1 Codabar Default All Codabar Settings CBRDFT 7 3 Off CBRENA0 7 3 On CBRENA1 7 3 Codabar Start Stop Char Don t Transmit CBRSSX0 7 3 Transmit CBRSSX1 7 3 Selection Setting Indicates default Serial Comman...

Page 239: ...idate CLSI and Transmit CBRCK26 7 4 Codabar Concatenation Off CBRCCT0 7 5 On CBRCCT1 7 5 Require CBRCCT2 7 5 Concatenation Timeout DLYCCT 7 5 Codabar Redundancy Range 0 10 0 CBRVOT 7 5 Codabar Message Length Minimum 1 80 3 CBRMIN 7 6 Maximum 1 80 80 CBRMAX 7 6 Code 39 Default All Code 39 Settings C39DFT 7 7 Off C39ENA0 7 7 On C39ENA1 7 7 Code 39 Start Stop Char Don t Transmit C39SSX0 7 7 Transmit ...

Page 240: ...erleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 7 11 Off I25ENA0 7 11 On I25ENA1 7 11 Follett Formatting Off I25FOL0 7 11 On I25FOL1 7 11 NULL Characters Off I25NUL0 7 11 On I25NUL1 7 11 Interleaved 2 of 5 Check Digit No Check Char I25CK20 7 12 Validate But Don t Transmit I25CK21 7 12 Validate and Transmit I25CK22 7 12 Interleaved 2 of 5 Redundancy Range 0 10 0 I25VOT 7 12 Interleav...

Page 241: ...Default All Code 93 Settings C93DFT 7 15 Off C93ENA0 7 15 On C93ENA1 7 16 Code 93 Redundancy Range 0 10 0 C93VOT 7 15 Code 93 Message Length Minimum 1 80 3 C93MIN 7 16 Maximum 1 80 80 C93MAX 7 16 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 7 16 Off R25ENA0 7 16 On R25ENA1 7 16 Straight 2 of 5 Industrial Redundancy Range 0 10 0 R25VOT 7 17 Straight 2 of 5 Indus...

Page 242: ...ault All Matrix 2 of 5 Settings X25DFT 7 19 Off X25ENA0 7 19 On X25ENA1 7 19 Matrix 2 of 5 Redundancy Range 0 10 0 X25VOT 7 20 Matrix 2 of 5 Message Length Minimum 1 80 3 X25MIN 7 20 Maximum 1 80 80 X25MAX 7 20 Matrix 2 of 5 Check Char No Check Char X25CK20 7 20 Validate But Don t Transmit X25CK21 7 20 Validate and Transmit X25CK22 7 20 Code 11 Default All Code 11 Settings C11DFT 7 21 Off C11ENA0 ...

Page 243: ...de 11 Redundancy Range 0 10 0 C11VOT 7 22 Code 11 Message Length Minimum 1 80 3 C11MIN 7 23 Maximum 1 80 80 C11MAX 7 23 Code 128 Default All Code 128 Settings 128DFT 7 24 Off 128ENA0 7 24 On 128ENA1 7 24 128 Group Separator Output Off 128GSE0 7 24 On 128GSE1 7 24 Code 128 Redundancy Range 0 10 0 128VOT 7 25 Code 128 Message Length Minimum 1 80 3 128MIN 7 25 Maximum 1 80 80 128MAX 7 25 ISBT 128 Off...

Page 244: ...duct Code 003 and Expiration Date Form 1 ISBPCS3 7 26 Product Code 003 and Expiration Date Form 2 ISBPCS4 7 26 Product Code 003 and Expiration Date Form 3 ISBPCS5 7 26 Product Code 003 and Expiration Date Form 4 ISBPCS6 7 26 ISBT 128 Predefined Concatenation Sequences On Off Off ISBPCE0 7 27 Allow Predefined Sequence ISBPCE1 7 27 Require Predefined Sequence ISBPCE2 7 27 Selection Setting Indicates...

Page 245: ...nt Verification Off ISBXM00 7 29 On ISBXM01 7 29 Transmit Identifiers Off ISBXM10 7 30 On ISBXM11 7 30 Flag Conversion Off ISBXM20 7 30 On ISBXM21 7 30 GS1 128 Default All GS1 128 Settings GS1DFT 7 31 On GS1ENA1 7 31 Off GS1ENA0 7 31 GS1 128 Application Identifier Parsing Off GS1EMU0 7 31 Transmit Without Identifiers GS1EMU1 7 31 Transmit With Identifiers GS1EMU2 7 31 GS1 128 Redundancy Range 0 10...

Page 246: ...f UPAENA0 7 36 On UPAENA1 7 36 UPC A Number System Off UPANSX0 7 35 On UPANSX1 7 35 UPC A Check Digit Off UPACKX0 7 35 On UPACKX1 7 36 UPC A 2 Digit Addenda Off UPAAD20 7 36 On UPAAD21 7 36 UPC A 5 Digit Addenda Off UPAAD50 7 36 On UPAAD51 7 36 UPC A Addenda Required Not Required UPAARQ0 7 36 Required UPAARQ1 7 36 Addenda Timeout Range 0 65535 100 DLYADD 7 37 UPC A Addenda Separator Off UPAADS0 7 ...

Page 247: ... Require 2 Digit Addenda ARQSY51 7 40 Require 5 Digit Addenda ARQSY52 7 40 Require 2 or 5 Digit Addenda ARQSY53 7 40 Require Coupon Code ARQSY54 7 40 Require Coupon Code or 2 Digit Addenda ARQSY55 7 40 Require Coupon Code or 5 Digit Addenda ARQSY56 7 40 Require Coupon Code 2 Digit Addenda or 5 Digit Addenda ARQSY57 7 40 Addenda Timeout Range 0 65535 100 DLYADD 7 41 UPC E0 Default All UPC E Setting...

Page 248: ... UPEARQ0 7 43 Addenda Timeout Range 0 65535 100 DLYADD 7 44 UPC E0 Addenda Separator On UPEADS1 7 44 Off UPEADS0 7 44 UPC E0 Redundancy Range 0 10 1 UPEVOT 7 44 EAN JAN 13 Default All EAN JAN Settings E13DFT 7 45 Off E13ENA0 7 45 On E13ENA1 7 45 EAN JAN 13 Check Digit Off E13CKX0 7 45 On E13CKX1 7 45 EAN JAN 13 2 Digit Addenda 2 Digit Addenda On E13AD21 7 46 2 Digit Addenda Off E13AD20 7 46 5 Digi...

Page 249: ...1 7 48 Require 5 Digit Addenda ARQ3782 7 48 Require 2 or 5 Digit Addenda ARQ3783 7 48 EAN 13 Beginning with 414 419 Addenda Required Don t Require Addenda ARQ4140 7 49 Require 2 Digit Addenda ARQ4141 7 49 Require 5 Digit Addenda ARQ4142 7 49 Require 2 or 5 Digit Addenda ARQ4143 7 49 EAN 13 Beginning with 434 439 Addenda Required Don t Require Addenda ARQ4340 7 50 Require 2 Digit Addenda ARQ4341 7 ...

Page 250: ...quire 5 Digit Addenda ARQ9791 7 51 Addenda Timeout Range 0 65535 100 DLYADD 7 52 EAN JAN 13 Addenda Separator Off E13ADS0 7 52 On E13ADS1 7 53 EAN JAN 13 Redundancy Range 0 10 0 E13VOT 7 52 ISBN Translate Off E13ISB0 7 53 On E13ISB1 7 53 Convert to 13 Digit On E13I131 7 53 Convert to 13 Digit Off E13I130 7 53 Reformat On E13IBR1 7 53 Reformat Off E13IBR0 7 53 ISSN Translate Off E13ISS0 7 54 On E13...

Page 251: ...ge 0 65535 100 DLYADD 7 57 EAN JAN 8 Addenda Separator Off EA8ADS0 7 57 On EA8ADS1 7 57 EAN JAN 8 Redundancy Range 0 10 0 EA8VOT 7 57 MSI Default All MSI Settings MSIDFT 7 58 Off MSIENA0 7 58 On MSIENA1 7 58 MSI Check Character Validate Type 10 but Don t Transmit MSICHK0 7 59 Validate Type 10 and Transmit MSICHK1 7 59 Validate 2 Type 10 Chars but Don t Transmit MSICHK2 7 59 Validate 2 Type 10 Char...

Page 252: ...0 0 PLSVOT 7 61 Plessey Message Length Minimum 1 80 3 PLSMIN 7 61 Maximum 1 80 80 PLSMAX 7 61 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings RSSDFT 7 62 Off RSSENA0 7 62 On RSSENA1 7 62 GS1 DataBar Omnidirectional Redundancy Range 0 10 0 RSSVOT 7 62 GS1 DataBar Limited Default All GS1 DataBar Limited Settings RSLDFT 7 63 Off RSLENA0 7 63 On RSLENA1 7 63 GS1 DataBar Li...

Page 253: ...ation EANEMU1 7 66 GS1 DataBar Emulation EANEMU2 7 66 GS1 Code Expansion Off EANEMU3 7 66 EAN8 to EAN13 Conversion EANEMU4 7 66 GS1 Emulation Off EANEMU0 7 66 Postal Codes China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings CPCDFT 7 66 Off CPCENA0 7 67 On CPCENA1 7 67 China Post Hong Kong 2 of 5 Redundancy Range 0 10 0 CPCVOT 7 67 China Post Hong Kong 2 of 5 Msg Length Min...

Page 254: ...10 44 Serial Trigger Commands Read Time Out 0 300 000 30 000 ms TRGSTO 10 4 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 255: ...ng Drop Operational after 30 drops to concrete from 5 ft 1 5m Environmental Sealing IP42 Light Levels 0 70 000 lux direct sunlight ESD 16kV 9kV contact Scan Performance Scan Pattern Single scan line Scan Angle Horizontal 30 Scan Speed 100 scan lines per second Print Contrast 10 minimum reflectance difference Pitch Skew 60 60 Decode Capabilities Reads standard 1D and GS1 DataBar symbologies DOF wit...

Page 256: ... 229mm 0 9 in 13 mil UPC A 0 253mm 0 10 in 20 mil Code 39 0 293mm 0 11 5 in Laser Beam Wavelength 645 660 nm Divergence 1 5 mrad per IEC 60825 1 worst case Maximum Power Output 1 mw Embedded Laser Wavelength 645 660 nm Divergence 1 5 mrad per IEC 60825 1 worst case Maximum Power Output 10 mw Parameter Specification ...

Page 257: ...s USB power Radio Frequency 2 4 to 2 5 GHz ISM Band Frequency Hopping Bluetooth v 2 1 Range 33 ft 10 m typical line of sight Data Rate Up to 3 MBps Environmental Temperature Ranges Operating Charging 41 F to 104 F 5 C to 40 C Operating Non Charging 32 F to 122 F 0 C to 50 C Storage 23 F to 95 F 5 C to 35 C Humidity 0 to 95 relative humidity non condensing Mechanical Drop Designed to withstand 30 d...

Page 258: ...UPC A 0 311mm 0 12 2 in 20 mil Code 39 0 367mm 0 14 4 in Guaranteed Performance 5 mil Code 39 38 132mm 1 5 5 2 in 7 5 mil Code 39 26 189mm 1 7 4 in 10 4 mil Code 39 0 229mm 0 9 in 13 mil UPC A 0 253mm 0 10 in 20 mil Code 39 0 293mm 0 11 5 in Laser Beam Wavelength 645 660 nm Divergence 1 5 mrad per IEC 60825 1 worst case Maximum Power Output 1 mw Embedded Laser Wavelength 645 660 nm Divergence 1 5 ...

Page 259: ...o 2 5 GHz ISM Band Frequency Hopping Bluetooth v 2 1 Range 33 ft 10 m typical line of sight Data Rate Up to 3 MBps Temperature Ranges Operating Charging 41 F to 104 F 5 C to 40 C Operating Non Charging 32 F to 122 F 0 C to 50 C Storage 23 F to 95 F 5 C to 35 C Humidity 0 to 95 relative humidity non condensing Environmental Mechanical Drop Operational after 30 drops from 3 28 feet 1m to concrete ES...

Page 260: ...11 6 CCB00 010BT Mounting 3 07 in 78mm Use 2 M3x15mm PHP self tapping wood screws ...

Page 261: ...inal data 5 Terminal clock 6 Keyboard clock 7 Supply power input 5V power 8 Keyboard data 9 10 Note Pin assignments are not compatible with Honeywell legacy products Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty ...

Page 262: ...nd 4 Transmit data 5 Receive data serial data to scanner 6 CTS 7 5V power 8 RTS 9 10 Note Pin assignments are not compatible with Honeywell legacy products Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty ...

Page 263: ...data serial data to scanner 6 7 5V power 8 Transmit Enable 9 10 Note RS485 signal conversion is performed in the cable Pin assignments are not compatible with Honeywell legacy products Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty ...

Page 264: ...ect 3 Supply ground 4 5 6 7 5V power 8 9 Data 10 Data Note Pin assignments are not compatible with Honeywell legacy products Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty ...

Page 265: ...only The scanner and base s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the interface cable and connector for wear or other signs of dam age A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replace ment Cable replacement instructions are on page 12 1 Replacing Cables in Corded Scan...

Page 266: ... release 4 Straighten one end of a paper clip 5 Insert the end of the paper clip into the small hole and press in This depresses the retention tab releasing the connector Pull the connector out while maintaining pressure on the paper clip then remove the paper clip 6 Replace with the new cable Insert the connector into the opening and press firmly The connector is keyed to go in only one way and w...

Page 267: ...t on If your scanner is not functioning properly review the following Troubleshooting Guide to try to isolate the problem Is the power on Is the laser aimer on If the laser aimer isn t illuminated check that The cable is connected properly The host system power is on if external power isn t used The button works Is the scanner having trouble reading your symbols If the scanner isn t reading symbol...

Page 268: ...ays A12345B Reprogram the scanner with the proper symbology selections See Chapter 7 The scanner won t read your bar code at all 1 Scan the sample bar codes in the back of this manual If the scanner reads the sample bar codes check that your bar code is readable Verify that your bar code symbology is enabled see Chapter 7 2 If the scanner still can t read the sample bar codes scan All Symbologies ...

Page 269: ...If the scanner isn t reading symbols well check that the symbols Aren t smeared rough scratched or exhibiting voids Aren t coated with frost or water droplets on the surface Are enabled in the base or Access Point to which the scanner connects Is the bar code displayed but not entered into the application The bar code is displayed on the host device correctly but you still have to press a key to e...

Page 270: ...int with the proper symbology selections See Chapter 7 The scanner won t read your bar code at all Scan the sample bar codes in the back of this manual If the scanner reads the sample bar codes check that your bar code is readable Verify that your bar code symbology is enabled see Chapter 7 If the scanner still can t read the sample bar codes scan All Symbologies on page 7 1 ...

Page 271: ...eceive attachments Web form www hsmcontactsupport com You can contact our technical support team directly by filling out our online support form Enter your contact details and the description of the question problem Telephone www honeywellaidc com locations For our latest contact information please check our website at the link above Product Service and Repair Honeywell International Inc provides ...

Page 272: ...at www honeywellaidc com Limited Warranty Honeywell International Inc HII warrants its products to be free from defects in materials and workmanship and to conform to HII s published specifications applicable to the products purchased at the time of shipment This warranty does not cover any HII product which is i improperly installed or used ii dam aged by accident or negligence including failure ...

Page 273: ...BE LIABLE FOR INDIRECT INCIDENTAL OR CONSE QUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CON TRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL AMOUNT PAID TO HII FOR THE PRODUCT THESE LIMITATIONS ON LIA BILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII MAY HAVE BEEN ADV...

Page 274: ...13 4 ...

Page 275: ... 0x51 Chinese Sensible Code Han Xin Code X0 H 0x48 Codabar Fm 0 1 a 0x61 Codablock A O6 0 1 4 5 6 V 0x56 Codablock F Om 0 1 4 5 6 q 0x71 Code 11 H3 h 0x68 Code 128 Cm 0 1 2 4 j 0x6A GS1 128 C1 I 0x49 Code 32 Pharmaceutical PARAF X0 0x3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 0x62 Code 49 Tm 0 1 2 4 l 0x6C Code 93 and 93i Gm 0 9 A Z a m i 0x69 Data Matrix dm 0 6 w 0x77 EAN 13 including B...

Page 276: ...5 Japanese Post X0 J 0x4A KIX Netherlands Post X0 K 0x4B Korea Post X0 0x3F Matrix 2 of 5 X0 m 0x6D MaxiCode Um 0 3 x 0x7 8 MicroPDF417 Lm 3 5 R 0x52 MSI Mm 0 g 0x67 NEC 2 of 5 X0 Y 0x59 OCR MICR E 13 B o3 O 0x4F OCR SEMI Font o3 O 0x4F OCR A o1 O 0x4F OCR B o2 O 0x4F PDF417 Lm 0 2 r 0x72 Planet Code X0 L 0x4C Postal 4i X0 N 0x4E Postnet X0 P 0x50 QR Code and Micro QR Code Qm 0 6 s 0x73 Straight 2...

Page 277: ...s 99 entry Refer to Data Editing beginning on page 5 1 and Data Formatting beginning on page 6 1 for information about using Code ID and AIM ID Straight 2 of 5 Industrial S0 f 0x66 TCIF Linked Code 39 TLC39 L2 T 0x54 Telepen Bm t 0x54 UPC A E0 c 0x63 UPC A with Add On E3 c 0x63 UPC A with Extended Coupon Code E3 c 0x63 UPC E E0 E 0x45 UPC E with Add On E3 E 0x45 UPC E1 X0 E 0x45 Symbology AIM ID P...

Page 278: ...MENT NAK 6 6 ACKNOWLEDGE ACK 22 16 SYNCHRONIZE SYN 7 7 BEEP BEL 23 17 END OF TRANSMISSION BLOCK ETB 8 8 BACKSPACE BS 24 18 CANCEL CAN 9 9 HORIZONTAL TAB HT 25 19 END OF MEDIUM EM 10 A LINE FEED LF 26 1A SUBSTITUTE SUB 11 B VERTICAL TAB VT 27 1B ESCAPE ESC 12 C FF FORM FEED 28 1C FILE SEPARATOR FS RIGHT ARROW 13 D CR CARRIAGE RETURN 29 1D GROUP SEPARATOR GS LEFT ARROW 14 E SO SHIFT OUT 30 1E RECORD...

Page 279: ... 120 78 x 57 39 9 89 59 Y 121 79 y 58 3A 90 5A Z 122 7A z 59 3B 91 5B 123 7B 60 3C 92 5C 124 7C 61 3D 93 5D 125 7D 62 3E 94 5E 126 7E 63 3F 95 5F _ 127 7F DEL Extended ASCII Characters DEC HEX Character DEC HEX Character DEC HEX Character 128 80 171 AB 214 D6 Ö 129 81 172 AC 215 D7 130 82 173 AD 216 D8 Ø 131 83 ƒ 174 AE 217 D9 Ù 132 84 175 AF 218 DA Ú 133 85 176 B0 219 DB Û 134 86 177 B1 220 DC Ü ...

Page 280: ...48 94 191 BF 234 EA ê 149 95 192 C0 À 235 EB ë 150 96 193 C1 Á 236 EC ì 151 97 194 C2  237 ED í 152 98 195 C3 à 238 EE î 153 99 196 C4 Ä 239 EF ï 154 9A š 197 C5 Å 240 F0 ð 155 9B 198 C6 Æ 241 F1 ñ 156 9C œ 199 C7 Ç 242 F2 ò 157 9D 200 C8 È 243 F3 ó 158 9E ž 201 C9 É 244 F4 ô 159 9F Ÿ 202 CA Ê 245 F5 õ 160 A0 203 CB Ë 246 F6 ö 161 A1 204 CC Ì 247 F7 162 A2 205 CD Í 248 F8 ø 163 A3 206 CE Î 249 F9...

Page 281: ...cters 83 ISO 2022 69 Fra French Belgium Replacement Characters 81 ISO 2022 25 Fra French Belgium Replacement Characters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 Ita Italian Replacement Characters 86 ISO 2022 11 Swi Swiss Replacement Characters 87 ISO 2022 11 UK British Replacement Characters 88 ISO 2022 11 Dan Danish Replacement Characters 89 ISO 2022 11 Nor Norwegian Replac...

Page 282: ...A 8 ...

Page 283: ......

Page 284: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 285: ...Sample Symbols 6543210 GS1 DataBar 01 00123456789012 Matrix 2 of 5 ...

Page 286: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...

Page 287: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A C B F E D Save Discard Reset ...

Page 288: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 VG1200 UG Rev B 11 11 ...

Reviews: