11
1.5.5 Camera In Connector
(PS/2 composition of female connector)
PIN NO.
PIN Assignment
1.
Audio In
2.
Not Connected (Mirror)
3.
+ 12V DC
4.
Video In
5.
Ground
6.
Ground
Note: The maximum electric current provided for 4 mobile cameras is 1 ampere ( 1A ) in total.
1.5.6 Power Delay Connection
The diagram here illustrates the power delay connection structure. If a device needs to work with our
DVR, it needs to start operating
after
our DVR has begun operating. See the diagram below to help
you with the mobile vehicle video recorder's power delay connector on its rear panel.
Enter the mobile vehicle DVR's
"MAIN MENU"
page and choose the third item,
"CLOCK / TITLE".
Now
enter the
"CLOCK / TITLE"
page, and you will see two items,
"DELAY ON"
and
"DELAY OFF".
For both
these items, the default setting is
"OFF".
You can set the delay time of the relay by choosing one of the
following options.
DELAY ON:
This entry sets the delay time of the function activation of the relay connector after the DVR
powers up.
DELAY OFF:
This entry sets the delay time of the function activation of the relay connector after the ACC is
powered off. The relay connector will function as per the delay time you set by your chosen
option. After the relay connector's delay time duration is over, the relay connector will
automatically turn off, followed by the DVR. (The DVR which is connect with a cigar-lighter of a
vehicle for power supply will stop working when turning off the ignition.)
Note
: The relay connector’s electric current range goes to a maximum of 30 amperes.
Note
: Our
"POST REC DURATION"
function also sets the time as per any of the six options available, after
the ACC has been turned off. Please always be mindful of the fact that, if the time duration set for
either
"DELAY OFF" or "POST REC DURATION"
is longer than the other one, the DVR will wait for
the longer setting to end before shutting down.