2. Install the Supply Feed
Wrap the slip joint adapter with Teflon tape, approximately 3 wraps.
a.
Flex Line
: Loosen nut and separate cold water riser tube
from faucet shank. Gently bend riser rube so that slip joint
fits onto faucet shank. Make sure the flat washer is on top
and the cone washer is on the bottom. Reinstall riser tubes
onto slip joint adapter and tighten.
b.
Solid Copper Riser Tube
: Same procedure as flex tubing
except you must cut a piece of the riser tube about ¾” to 1”
so the slip joint adapter can fit between faucet and riser tube
3. Connect the feed line to the ball valve.
Unscrew the nut from the ball valve. Slide the nut onto the tubing,
threaded sides facing the end of the tubing. Feed the nipple on the
ball valve into the tubing, pushing the tubing until it slides over the
lip. Slide the nut to the threads on the ball valve, and tighten the nut
down over the tubing. Use a wrench to tighten ¼ turn past finger-
tight.
4.
Connect the other end of the tubing to the feed port on the RO
System.
Feed Valve OPEN Position
Feed Valve CLOSED Position
Drain Saddle Installation
For this step you will need:
o
Variable speed drill w/
⅛
” and ¼" drill bits
o
Phillips
Screwdriver
Drain Saddle Assembly
Black Tubing