Installation and Service Manual – Under-the-Counter 6 Stage Reverse Osmosis System with UV
Systems and Components
Membranes
,
Filters
,
Chemicals
2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: [email protected]
Page 14
Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
System Maintenance
CAUTION
Unplug the Ultraviolet unit before performing any maintenance to the system.
Membrane Replacement Instructions
The membrane should be replaced every 1-2 years, depending on the water quality.
Before starting, shut off the cold water supply to the unit. Lift the handle on the faucet to drain out the storage tank
completely and allow the system to stand for 10 minutes in order to fully decompress the tank. Leave the faucet open
until the membrane change is complete.
1.
Unscrew the fitting to the cap of the membrane housing.
2.
Using pliers, pull out the old membrane from the housing.
3.
Remove the new membrane from its bag.
4.
Insert the membrane in the housing in the same direction as the old membrane.
5.
Push the membrane firmly into the housing until it seats on the far end.
6.
Screw the housing cap back on, making sure the o-ring is positioned correctly.
7.
Screw the fitting (with tubing) back onto the housing.
8.
The system is ready. Turn on the water supply. Check for any leaks.
9.
Drain the first two tanks of water before drinking.
Filter Replacement Instructions
All pre-and post filters should be replaced every 6 months.
Before starting, shut off cold water supply to unit. Lift the handle on the faucet to drain out the storage tank completely
and allow the system to stand for 10 minutes in order to fully decompress the tank, reserving some of the RO water to use
to rinse the filter housings. Leave the faucet open until the filter change is complete.
1.
Remove pre-filters from filter housings. Use a filter wrench if the housings are too tight.
2.
Discard used filters, but save o-rings for re-use.
3.
Clean inside of all housings with a mild soap solution, and then rinse with RO water.
4.
Lubricate the o-ring and replace in filter housing.
5.
Insert the new filters into the appropriate housings and replace the housings onto the system.
6.
Disconnect the post-filter by removing the fittings on either end. Replace with new post-filter and re-use the existing
fittings.
(Feed end tee is connected by a short length of tubing, remove this and use to connect to new filter.)
7.
Follow the normal Start-up Procedures. (Drain the first tank of water after changing the filters before drinking.)