Installation and Service Manual – Under-the-Counter 6 Stage Reverse Osmosis System with UV
Systems and Components
Membranes
,
Filters
,
Chemicals
2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: [email protected]
Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
Page 13
Turning the System On for the First Time
Make sure all water supply /drain lines are secure and free from leaks.
Slowly turn the feed valve counterclockwise until fully open (the handle should be in line with the tubing as it
enters the connection). Check the stem seal for leakage. If necessary, tighten stem nut lightly.
Turn storage tank valve one quarter turn counterclockwise to open the valve (the handle should be in line with
the tubing as it enters the connection).
Open the product water faucet and let the water flow until all the air has been expelled from the system. This
will take about an hour.
Close the product water faucet. In 30 minutes, check the connections for leaks and correct if necessary.
Do Not Use the First Two Reservoirs of Water
Allow the reservoir to fill for 4-6 hours. Dispense this water to drain. This process
removes the factory installed sanitizing solution from the entire system and sends it to the
drain. Repeat this process one more time. Allow the tank to fill for 4-6 hours and
dispense this water to the drain. Do not drink this water!
Note: Air bubbles may be present in the product water after initial system startup, causing a milky color in the
water. This is normal and safe to drink. The air bubbles will disappear within a few days of regular use.