Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System with Booster Pump
Copyright © 2014 Applied Membranes, Inc.
All Rights Reserved.
Page 8
3. Connect the feed line to the ball valve.
Unscrew the nut from the ball valve. Slide the nut onto the tubing,
threaded sides facing the end of the tubing. Feed the nipple on the
ball valve into the tubing, pushing the tubing until it slides over the
lip. Slide the nut to the threads on the ball valve, and tighten the nut
down over the tubing. Use a wrench to tighten ¼ turn past finger-
tight.
4.
Connect the other end of the tubing to the feed port on the RO
System.
Feed Valve OPEN Position
Feed Valve CLOSED Position
Drain Saddle Installation
For this step you will need:
o
Variable speed drill w/
⅛
” and ¼" drill bits
o
Phillips
Screwdriver
Drain Saddle Assembly
Black Tubing
1. Drill a ¼” hole in the drain pipe
a. Select a location for the drain hole based on the design of the plumbing. It should be installed above
the trap and on the vertical or horizontal tail piece. Locate the drain connection away from the
garbage disposal to prevent potential contamination and system fouling.
b. Starting with the
⅛
” drill bit, drill a
⅛
” hole in the drain pipe. Use the ¼” drill bit to enlarge the hole.
Clean the debris from the pipe and the hole before continuing.