1.5.2. Connectors
Mains Input
200 – 250 VAC mains input. Connection details are supplied elsewhere in this manual.
Remote
Allows operator to remotely control CSP-N.
HV Output
4 pin proprietary connector. Using our HV2 plug, the large connector pins are proof tested to 6000
volts and can operate with current pulses up to 8000 amps. The two small pins are used as
interlock pins. If these are left open circuit, the CSP-N will not be able to enable the high voltage
(INTERLOCK fault).
Trigger Input
The trigger input is connected via a BNC socket.
1.6. Rear Panel
Fuses
The rear panel contains 2 fuse holders, and these are the only things we recommend the operator
checks if he has not received factory training. The fuses are rated as follows:-
F1
3A Antisurge 1¼"
(240V)
F2
3A Antisurge 1¼"
(240V)
Charge Rate Switch
Recommended position is OUT to make use of the AVIP circuitry.
Fan Filters
The rear panel of the units has 2 fold-down handles to ease installation, and also has 2 fan filters
for the cooling air intake. These filters should be periodically cleaned to ensure maximum air flow.
This can be done with a small stiff brush.
SAFETY NOTICE
All interlocks and safety features are doubled. For example, if the HV connector is removed, the
HV is shut OFF by the logic board which controls the charger module AND the high voltage is
switched OFF by a separate relay. The interlock circuit operates from its own isolated 12V supply
and operates 2 relays, as well as the control electronics. However, it cannot be stressed enough
that the operator and all those who might come into contact with this equipment treat it with
extreme caution and should not take any safety feature for granted.