Safety Features
Should any fault develop, the high voltage PSU (Charger) and all capacitors (which have bleed
resistors) are individually dumped to ground, until the system is reset. A double layer of safety cut-
outs ensure that partial failure results in system shutdown.
Interlocks
: Dumps high voltage when fault develops.
Time Out
: Shut down after period (~30 seconds) without key pulse.
Local/Remote
: Disables remote (if fitted).
Load Fault
: Shuts down HV upon open circuit load or load over current.
Reset
: Resets unit after fault or if interlock activated.
Key switch
: Must be rotated to enable high voltage. Switch can be
removed to disable unit for example when working on deck.
Thermal shut-down
: HV charger shuts down if it overheats.
Options
Remote
: Allows operator to control unit at a distance. Includes key
pulse line.
Junction Box
: For connection of standard transducer cables to HV connector.
Shock Mount Housing
: For transportation and operation. (Recommended.)
Transit Case
: For storage and transportation. Foam lined.
Field Spares Kit
: For trained technicians only. For servicing units in the field.