10. Data Output format
A
PPLIED
A
COUSTIC
E
NGINEERING
R
ANGE
D
ATA STRING
Beacon # Range = rrrr.r M Depth = dddd.d M CL
Beacon identification (1 to 4)
#
Range in meters
r
Depth in meters
d
Carriage return (CR)
C
Line Feed (LF)
L
A
PPLIED
A
COUSTIC
E
NGINEERING
T
EST
D
ATA STRING
Beacon # TAT = ttt.t ms Frequency = fffff.f Hz PW = pp.p ms CL
Beacon identification (1 to 4)
#
TAT (Turnaround Time) in ms
t
Frequency (Reply Frequency) in Hz
f
PW (Reply Pulse Width) in ms
f
Carriage return (CR)
C
Line Feed (LF)
L
Note fields are ‘space’ separated.
Example strings
“Range”
string
Beacon 1 1011.1 M Depth = 525.5 M
“Test” string
Beacon 1 TAT = 30.1 ms Frequency = 28409.0 Hz PW = 10.0 ms