F2 Rx Tx Parameters
System parameters can be configured from this menu using the cursor keys to select and return
key to confirm.
Transmit (Tx) Power (Dunker:
High // Low
Speed of Sound (in Water):
300 to 1600 m/s
Enter the Velocity Of Sound (VOS) for transmission through water to be used in the range
calculation. This is the mean velocity
Sound Mode (Speaker):
Tone // Received Signal
Speaker Volume:
User specified level
Test Interval (Update Rate in ms): User specified 0 to 9999 ms