POS MV V5 Installation and Operation Guide
Fault
Identification
Copyright © Applanix Corporation, 2017
9-31
Figure 76: POSView Input/Output Port Setup
Note:
Dynamically configurable COM ports add great flexibility, but can also cause problems if
inadvertently reassigned.
To check the output functions (NMEA and Binary) perform the following steps:
1. Ensure that POS is navigating and is in
Degraded Nav
mode or better. Binary data is not output
until this mode is reached.
2. Select
Diagnostics, NMEA & Binary Output
from controller menu bar. Verify displayed
Port#
matches selected COM port (e.g.
Port#
1 = COM 1), see Figure 77.
3. Check
Write Failure
field. If value increases, indicates PCS hardware interface problem; try
another COM port. Reassign NMEA or Binary output to unused COM port. If communications
restored, note defective COM port for future reference.