TERMS IN THIS MANUAL 

 

These terms may appear in this manual: 

               

WARNING: Warning statements identify condition or practices that could result in 

injury or loss of life. 

CAUTION: Caution statements identify conditions or practices that could result in 

damage to this product or other property. 

 

DISPOSE OF PROPERLY 

NOTE 

 

SYMBOLS ON THE PRODUCT LABELING  

  Number following this symbol indicates the serial number of the Equipment   

  

Character following the symbol indicates the Model number of the Equipment         

 

Consult User’s Manual

 

               

Caution, refer to accompanying documents 

      

Manufactured By   

     Temperature Limitations                    

   Keep away from Sunlight 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AA3 SUPER DELUXE

Page 1: ...AA3 SUPER DELUXE CRYO FROM YOUR RELIABLE PEOPLE APPASAMY ASSOCIATES User Manual DOC ID RD 7 3 13 CRYO REV 01 Jan 2012 ...

Page 2: ...USE 5 8 CONTRAINDICATION 6 9 IMPORTANT SAFETY MAINTENCANCE INSTRUCTIONS 5 10 CLEANING AND DISINFECTION INFORMATION 4 11 ENVIRONMENTAL CONSIDERATION 5 12 PRODUCT SPECIAL FEATURES 7 13 TECHNICAL DATA 7 14 PARTS DESCRIPTION 8 15 FOOTSWITCH DESCRIPTION 8 16 CRYOPROBE CARE AND MAINTENANCE 12 17 UNPACKING 12 18 INSTALLATION INSTRUCTIONS 13 19 STERILIZATION INSTRUCTIONS 13 20 FAULT DIAGNOSIS 11 21 WARRAN...

Page 3: ...uilding in which the equipment is to be used must comply with regulations specified by the country in which the equipment to be used The equipment used in accordance with the instructions for use mentioned in the operating manual provide by APPASAMY ASSOCIATES All modifications and repairs to the equipment are carried out by authorized APPASAMY ASSOCIATES personnel or their agents The equipment mu...

Page 4: ...installation instruction of the CRYO AA3 SUPER DELUXE Fault Diagnosis We hope that this manual meets your needs The Research Development department at APPASAMY ASSOCIATES would appreciate any comments you can share with us Kindly feel free to send your feedbacks suggestions and clarifications to our e mail APPASAMY ASSOCIATES 20 SBI Officer s Colony 1st street Arumbakam Chennai 600 106 Tamil nadu ...

Page 5: ...ts identify conditions or practices that could result in damage to this product or other property DISPOSE OF PROPERLY NOTE SYMBOLS ON THE PRODUCT LABELING Number following this symbol indicates the serial number of the Equipment Character following the symbol indicates the Model number of the Equipment Consult User s Manual Caution refer to accompanying documents Manufactured By Temperature Limita...

Page 6: ... must be kept at room temperature for atleast six hours before use In case the unit does not function properly refer to the section FAULT DIAGNOSIS If the fault persists inform to the manufacturers Periodically check all gaskets and O rings I n case of doubt change the gaskets if even the slightest gas leakage CAUTION FOR USE Cautions are intended to alert you to importance of following the correc...

Page 7: ...g condition If the product isn t able to use after done all the Fault diagnosis in this manual CLEANING AND DISINFECTION INFORMATION Use Dry cloth to clean Dust Particles in the equipment Do not wipe the parts with hazardous solvent To prevent the plastic parts from discoloring or deteriorating do not use benzine thinner either or gasoline Wipe External cover with a dry cloth at regular interval E...

Page 8: ...atically Lightweight probe tips have high conductivity silver Useful for Cataract Retinal Detachment Glaucoma and Intravitreal Surgery Two years unconditional Warranty TECHNICAL DATA CRYOPROBES TECHNICAL DETAILS PROBE Tip size mm Tip Temperature Cataract Straight Curved 1 4 40 C Retinal Straight Curved 2 5 80 C Glaucoma Straight 3 5 80 C Intravitreal Straight 1 0 20 C Dimension Length 310mm Width ...

Page 9: ...AA3 SUPER DELUXE 9 AP APPASAMY ASSOCIATES PARTS DESCRIPTION Front panel Back panel 1 2 3 4 5 ...

Page 10: ...CIATES 1 Cryoprobe lead connector 2 ON OFF Indicator 3 Pressure Gauge 4 Footswitch Connector 5 Gas Connector FOOTSWITCH DESCRIPTION AA3 SUPER DELUXE Foot switch on fully Press Position Foot switch on Release Ideal Position PRESS DOWNWARD ...

Page 11: ...ed causing scratches or bend Sterilize Cryoprobe to prevent patient to patient infection See more details on chapter 19 Warranty of your Cryoprobe is based on normal usage UN PACKING Unpack the Equipment and save all packing materials They are specially designed to protect the Equipment and will make repacking easy if you ever need to ship your AA3 SUPER DELUXE After unpacking verifies the Packing...

Page 12: ... Mark INSTALLATION The initial installation will be done by Appasamy Associates Trained Engineers only After installation a performances check will be carried by Appasamy Associates Engineers Nobody is authorized to install the Medical Equipment except Appasamy Associates Engineers INSTALLATION INSTRUCTIONS Step 1 Unpack the Instrument and arrange all the materials from two Packing layers in the B...

Page 13: ...ER DELUXE 13 AP APPASAMY ASSOCIATES Fig 2 Step 2 Clamp the cylinder connection tubing yoke end to the cylinder Fig 3 and the other end to the Union seen at the back panel gas connecter inlet Fig 4 Fig 3 Fig 4 ...

Page 14: ...lace and not damaged Step 5 Connect the Cryoprobe BLACK lead in BLACK and WHITE lead in WHITE as indicated in the unit Fig 6 Fig 5 Fig 6 Step 6 Open the cylinder value fully Observe the pressure gauge readings The reading should read between 600 p s i to 900 p s i in nitrous oxide gas cylinder and 750 p s i to 1000 p s i with cabon dioxide GREEN MARK IN PRESSURE GAUGE ...

Page 15: ...lease the footswitch for defrosting Fig 8 After the operations is over first close the cylinder then press the footswitch and release the footswitch Vice versa for 3 to 4 times until the pressure gauge reads zero This is for removing the gas inside the unit Fig 9 Wait for five minutes before disconnecting the gas connector from the cylinder ...

Page 16: ...d be validated as per the equipment manufacturer s requirements FAULT DIAGNOSIS No PROBLEM CAUSE ACTION 1 Insufficient freezing Cylinder pressure lower that 40 kg cm 600 p s i Cylinder in cold Gas is not extra dry Change the Cylinder Change the Cylinder Always use pure gas 2 Excessive Freezing Liquid Nitrous oxide or carbon dioxide circulating within the probe Cylinder is not vertical Cylinder is ...

Page 17: ...t occluded contact the manufacturer WARRANTY APPASAMY ASSOCIATES Warranty for the instrument for a total period of two complete years from the date of delivery Our obligation under the warranty is limited to replace any part which shall upon examination at our factory be determined to have been defective Use the siphon type gas cylinder completely voids the warranty of the cryo unit and Cryoprobe ...

Page 18: ...th this instrument should be disposed of i for EU member countries in accordance with WEEE Directive on Waste Electrical and Electronic Equipment or ii for all other countries in accordance with local disposal and recycling laws CUSTOMER SUPPORT MARKETED AND SERVICED BY 20 SBI Officers Colony First Street Arumbakkam Chennai 600 106 INDIA Tel 91 44 32980153 32980154 Fax 91 44 23630721 23631208 Toll...

Reviews: