Programming 

Connection 

The device is programmed by RS-485 interface. During programming the device should be powered (according to specification). 
Power  and  interface  connectors  are  marked  (V,  GND,  A,  B).  The  device  can  be  programmed  by  using  programming  unit 
CODAP-RS485 and service PC software APConfig PC [SiOne]. 

 

Figure 6. Programming - Scheme of Connection 

 

Be care when connecting the device. Incorrect connection may damage the device and/or damage other devices that are connected 
to the device or system 
All connections must only be made with the power off!

 

 

The device is programmed via RS-485 (MODBUS RTU) and all rules (chapter Communication protocol) apply to the RS-485 interface. 
Programming unit CODAP-RS485 is seen in Windows as a virtual COM port. 
Some versions of Windows may require the installation of drivers for the programming unit.

 

Summary of Contents for SiOne

Page 1: ...www apone eu SiOne Programmable transmitter for climate control with RS485 MODBUS RTU interface and up to 3 analog outputs Instruction manual 20180111 0910...

Page 2: ...d elements block diagram 5 Technical data 6 Basic technical data 6 Measurement technical data 7 Inputs and outputs 9 Power supply 9 Interface RS 485 10 Analog outputs refers to selected versions 11 Co...

Page 3: ...truction manual was prepared in detail by product specialists and is a technical description of the device without any responsibilities or implications of commercial law The forthcoming information sh...

Page 4: ...nting Recommendations The device was designed to provide the some level of resistance to disturbances that can occur in industrial environments In environments with an unknown level of interference th...

Page 5: ...can program the SiOne transmitter change standard analog outputs scale analog outputs check measuring parameters by using the programming unit CODAP RS485 and service PC software APConfigPC SiOne Fig...

Page 6: ...no 3 for Si A3 version L1 LED red indicator of power supply L2 LED green indicator of transmission 1 10 Configuration DIP Switches MODBUS address RS485 baud rate analog outputs standard Table 1 Termin...

Page 7: ...Cross section of wires 14 20 AWG 2 08 0 516 mm2 Si Cx Dy Wx when x 0 1 2 5 and y 1 2 versions Screw connection terminal separable Cross section of wires 16 28 AWG 1 31 0 081 mm2 Housing Material ABS...

Page 8: ...or integrated Si D50 Differential air pressure Temperature 500 500 Pa 14 140 F 10 60 C 0 1 Pa 3 WO 3 6 F 2 0 C Digital sensor integrated Si H00 Humidity Temperature 0 100 RH Max 148 392 F 100 200 C 0...

Page 9: ...ne Si T00 Si CA0 Si QMA Humidity Temperature Carbon dioxide CO2 Air pressure 0 100 RH 4 140 F 20 60 C Max 0 10000 ppm 0 1 800 1100 hPa 2 0 RH 0 9 F 0 5 C 40 ppm 3 WO 2 hPa 3 in 1 model of the SiOne Si...

Page 10: ...e power connection is made using the terminal block located under the cover of the device Power connectors are marked V and GND Figure 3 Power Supply Scheme of Connection Be care when connecting the d...

Page 11: ...website http www modbus org Interface connectors are marked A B RS 485 baud rate and MODBUS address are configured via jumpers Figure 4 shows a simple scheme of connection two SiOne transmitters in on...

Page 12: ...ately Each output can be freely scaled to the desired measuring range by using the programming unit and service PC software Output connectors are marked 1 output no 1 Si A1 Si A2 Si A3 versions 2 outp...

Page 13: ...jumper OFF or 1 jumper ON 1 2 3 4 5 6 7 8 9 10 ON Analog outputs type configured via jumpers no 8 10 Configured via MODBUS Z8 0 Z9 0 Z10 0 Standard 0 5 V Z8 1 Z9 0 Z10 0 Standard 0 10 V Z8 0 Z9 1 Z10...

Page 14: ...ipped with two LEDs that signal the operating status of the device facilitating the transmitter s initial start up Description of LEDs functions LED red L1 indicator of power supply constant solid lig...

Page 15: ...h the SiOne transmitter Baud rate Configured via jumpers 9600 19200 38400 57600 Data format 8 Stop bits 1 Parity none Transmission control none MODBUS address Configured via jumpers 1 32 Communication...

Page 16: ...ctions additional functions have been implemented in the device including program reset factory reset device name and version readout Function address Description 0x01HEX Read single bit 0x03HEX Read...

Page 17: ...17 Reserved 2 Internal sensor error Si B00 and combi version with Si B00 18 Reserved 3 Internal sensor error Si S00 and combi version with Si S00 19 Reserved 4 Internal sensor error Si Cx0 and combi v...

Page 18: ...rent output 4 20 mA Function is active only when jumpers no 8 9 and 10 are removed set to 0 1DEC Standard of analog output no 2 Si A2 Si A3 version 2DEC Standard of analog output no 3 Si A3 version 3D...

Page 19: ...maximum output signal analog output no 1 Si A1 Si A2 Si A3 version 0x03HEX 0x10HEX REAL 14DEC 15DEC Measurement value for maximum output signal analog output no 2 Si A2 Si A3 version 0x03HEX 0x10HEX R...

Page 20: ...REAL 28DEC 29DEC Number of sent communication frame via RS485 0x04HEX DWORD 30DEC 31DEC Number of received communication frame via RS485 0x04HEX DWORD 32DEC Humidity Si H00 and Si Q with Si H00 versio...

Page 21: ...ential air pressure Si Dx0 versions short version 0x04HEX INT Measurement value multiplied by 10 44DEC Temperature Si Dx0 versions short version 0x04HEX INT Measurement value multiplied by 10 Data typ...

Page 22: ...e Figure 6 Programming Scheme of Connection Be care when connecting the device Incorrect connection may damage the device and or damage other devices that are connected to the device or system All con...

Page 23: ...0 The language version of software can be changed from the software window Before programming select the appropriate COM port from the programming unit CODAP RS485 and set the appropriate transmission...

Page 24: ...nd performance parameters Basic Housing Detail Type of sensor Code XXX Code YYY Integrated only internal sensor s B00 Cx0 Dx0 S00 T00 QSx QTx QMA R0 Integrated internal and external sensor s S00 QSx Q...

Page 25: ...ted only external sensor S00 T00 W0 Integrated only external cable sensor 1 2 or 5 m cable length T00 W1 W2 W5 Connector for external sensor H00 C0 Cable connector for external sensor 1 2 or 5 m cable...

Page 26: ...1 m cable sensor H00 Humidity temperature for external probe W2 IP65 wall version 2 m cable sensor S00 Humidity temperature W5 IP65 wall version 5 m cable sensor T00 Temperature C0 IP65 wall version c...

Page 27: ...RH max 0 1 F 0 1 C Probe S3 External humidity and temperature probe For Si H00 Si QH Si QNA versions Measuring range 0 100 RH 58 212 F 50 100 C Accuracy Max 0 8 RH max 0 1 F 0 1 C Probe IC102 External...

Page 28: ...rsions CONBOX XY Connection Box For all SiOne transmitters It can be used in RS 485 network installation ZAS xx WT ZAS xx DIN Power supply units For all SiOne transmitters CODAP RS485 Programming unit...

Page 29: ...One transmitters Visualization function maps tables charts Archiving function save data to files on computer disk Alarming function also via e mails IDAPS www idaps eu Online software for climate moni...

Page 30: ...iOne transmitter contains Si transmitters 1 pc Gasket for housing cover only Si Cx Dy Wx when x 0 1 2 5 and y 1 2 version 1 pc Screw to close the housing cover only Si Cx Dy Wx when x 0 1 2 5 and y 1...

Page 31: ...Contact SiOne Page 30 Contact AP Automatyka S C tel 48 67 357 10 80 fax 48 67 357 10 83 email biuro apautomatyka pl http www apautomatyka pl...

Reviews: