![api technologies corp. 7608AD Series Installation And Operation Manual Download Page 34](http://html.mh-extra.com/html/api-technologies-corp/7608ad-series/7608ad-series_installation-and-operation-manual_2953494034.webp)
Installation and Operation Manual
ECN: 003155
Date: 06/4/2013
34
AC-SmartStart-7608-Series_IOM Rev 04
LAN Module & Communications
7.6.1.1 IP Address
The IP address must be set to a unique value in your network. Type in the new IP ad-
dress at the prompt. You may type a “.” between the number groups or press “Enter"
Note:
The LAN Module cannot connect to the network if the assigned IP address is
already in use by another device.
Note: Be sure to include a space between the IP address and 9999. The default IP
address is 192.168.1.10, so the command should look like “telnet 192.168.1.10 9999.”
This command will launch the configuration menu. After the first sentence appears,
press “ENTER” to go into the setup mode and the following menu will appear:
Figure 7.6 Server Configuration
Select
0
to configure the LAN module's basic parameters.
7.6.1 Server Configuration