Determines the type of Calculated Reading (Input Register 30303-04 and 30305-06) performed by the sensor
and associated Loss of Signal Error Code.
0 = Distance
1 = Level
2 = Standing Cylindrical Tank with or without Hemispherical Bottom
3 = Standing Cylindrical Tank with or without Conical Bottom
4 = Standing Rectangular Tank with or without Chute Bottom
5 = Horizontal Cylindrical Tank with or without Spherical Ends
6 = Spherical Tank
7 = Pounds (Linear Scaling)
8 = N/A
9 = Vertical Oval Tank
10 = Horizontal Oval Tank
11 = Strapping Chart
See MPX-E/R Application Type Parameters pages 26-30.
For Output 4, Loss of Signal Error Codes are dependent on Application Type. Loss of Signal for Application
Type 0 (Distance) is Max Distance (Holding Register 40405). For all other Application Types, Loss of Signal is
0.
•
MPX-E/R4 Modbus Sensor Parameters
40401 - Units
Determines the units of measure for the calculated reading when Application Type is set to 0, 1, or 7.
1 = Feet
2 = Inches
3 = Meters
40402 - Application Type
40403 - Volume Units
Determines the units of measure for the calculated reading when Application Type is set to 2 - 6 or 9 -11.
1 = Feet
3
5 = Liters
2 = Million Feet
3
6 = Inches
3
3 = Gallons
7 = Barrels
4 = Meters
3