11  Tester functions: 

  Calibration points indication: 

 

  Stable measurement: 

 

  Reading value auto. hold: 

HOLD

 

  Self-Diagnostic Information: 

Er2

 

  Low-Voltage warning:  

  flickering, reminder of battery replacement 

  Three-color backlight: 

  Blue

—Measurement Mode; Green—Calibration Mode; Red color—Alarm 

  Auto. Power-Off in 8 minutes without operation 

12  Electrode Replacement 

Twist off the probe ring, unplug the probe, plug in new probe 

(pay attention to the electrode’s 

position), and screw on the probe ring.  

The compatible model of replacement probe is ORP5-E / ORP60-E. 

13  Warranty 

We warrant this instrument to be free from defects in material and workmanship and agree to 

repair or replace free of charge, at option of APERA INSTRUMENTS (Europe) GmbH, any 

malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS 

(Europe) GmbH for a period of 

TWO YEARS (SIX MONTHS for the probe)

 from the delivery.  

This limited warranty does NOT cover any damages due to: 

Transportation, storage, improper use, failure to follow the product instructions or to perform any 

preventive maintenance, modifications, combination or use with any products, materials, 

processes, systems or other matter not provided or authorized in writing by us, unauthorized 

repair, normal wear and tear, or external causes such as accidents, abuse, or other actions or 

events beyond our reasonable control. 

 

 

 

 

 

 

 

 

 

 

 

APERA INSTRUMENTS (Europe) GmbH 

Wilhelm-Muthmann-Straße 18, 42329 Wuppertal, Germany 

www.aperainst.de

 | Contact: 

[email protected]

 | Tel. +49 202 51988998 

Summary of Contents for Premium ORP5

Page 1: ...ORP5 Premium Pocket ORP Tester APERA INSTRUMENTS Europe GmbH www aperainst de v3 1 ...

Page 2: ... the tester s cap while making sure to push all the way down The tester s waterproof design may be compromised if the cap is not fitted correctly 2 Keypad Functions Short press 2 seconds Long press 2 seconds 1 Short press to turn on the tester and long press to turn off the tester 2 When turned off long press to enter parameter setting 3 In measurement mode short press to turn on backlight 1 In ca...

Page 3: ...ottle 3 Short press to turn the meter on Long press to enter calibration mode If you need to exit calibration mode short press 4 Dip electrode in the standard buffer solution stir gently and allow it to stand still in the calibration solution until a stable reading is reached When stable icon comes up press to adjust the calibration value according to the table below also on the buffer bottle s la...

Page 4: ...d to clean and activate a For contamination caused by inorganic substances dip the probe into 0 1 mol L dilute hydrochloric acid for 30 minutes Clean it with distilled water soak it into the KCL storage solution for 6 hours and then it will be ready for use again b For contamination caused by organic substances and oiliness clean the platinum surface with dishwashing liquid and wash with distilled...

Page 5: ...mV stable icon displays on LCD Red back lit heads up displays B Automatic lock P3 Select On to activate auto lock function When reading is stable for more than 10 seconds the tester will lock the value automatically and HOLD icon will display on LCD Press key to cancel autohold C Backlight P4 Off turn off backlight On turn on backlight 1 backlight will last for 1 minute D Temperature Unit P5 Selec...

Page 6: ...epair or replace free of charge at option of APERA INSTRUMENTS Europe GmbH any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS Europe GmbH for a period of TWO YEARS SIX MONTHS for the probe from the delivery This limited warranty does NOT cover any damages due to Transportation storage improper use failure to follow the product instructions or to perform any pr...

Reviews: