APEN GROUP SPA reserves the right to contribute the necessary modifications to the documentation or documentation
16
cod. HG0130.05GB ed.B-2104
PCH
17
cod. HG0130.05GB ed.B-2104
PCH
PCH cold storage generator module
HG0130.00 A 010
Model
PCH
Front panel
kit
Code
Code
PCH020
G28881
PCH034
PCH045
G28882
PCH065
PCH080
G28883
PCH105
PCH130
G28884
PCH160
G28885
PCH210
PCH320
G28886
PCH420
G28887
PCH132
G28888
PCH162
G28889
PCH212
Model
PCH
Front panel
kit
Code
Code
PCH034-
00H0
G28878
PCH045-
00H0
PCH065-
00H0
PCH080-
00H0
G28879
PCH105-
00H0
Accessories
The front panel kit, as an accessory, must be ordered to APEN
GROUP by using the following codes:
Fitting the front panel and the door
To assemble the unit, proceed as follows:
•
apply, along the perimeter of the PCH housing galvanised
panel, a silicone bead to make the PCH heater outer
panel watertight, as shown in the figure (this application is
compulsory to ensure IPX5 protection for the equipment);
•
fix the front panel to the module, using the M6 x 16 front
screws;
•
secure the gas pipe to the front panel by using the seal
and the locknut;
•
fit the electrical cable clamps to the front or side panel,
according to the configuration of the machine;
•
fit the air intake fitting by inserting the black O-ring seal
between the front panel and the fitting; use the 8 self-tapping
M4 x 16 screws;
•
fit the locks on the door panel.
"B" type heater with combustion circuit open to the environment
in which it is installed
Fit the accessories for the combustion air inlet and the flue outlet
directed outwards (see the picture on the next page).
"C" type heater with combustion circuit sealed from the
environment in which it is installed
Fit the combustion air inlet and the flue outlet accessories
(see the picture on the next page) which must reach a suitable
external location.
The front panel kit includes the closing panel and the door to
be applied to the closing panel.
For installation in environments where the air temperature drops
below -15°C, we recommend to request the housing heating kit:
•
G28510
Kit installation, connection and adjustment modes inside the
warm air heater module are described in the installation manual.
Standard supply
Each PCH heater is supplied with some accessories, essential
to ensure correct installation:
•
1 intake terminal;
•
1 intake terminal for "B23" application;
•
1 flue outlet terminal;
•
no. 2 red silicone seals for flue outlet;
•
8 three-lobe M4 x 16 screws;
•
6 M6 x 16 screws;
•
6 washers;
•
6 red silicone rubber seals;
•
2 PG13.5 cable clamps;
•
1 green klin/sil seal (for gas locknut);
•
1 locknut for gas pipe;
•
4 1/4 slotted head locks.
NBR rubber seal, supplied
with PCH heater
Seal to be fitted on site with silicone.
Follow the profile shown in the picture