Page 19
APEN GROUP reserves the right to change products and documents as required.
code HG0109.12GB ed.C-1106 rev.12
WARM AIR HEATER SERIES RAPID
HG0109.12_ET_009
Terminal includes:
-Straight pipe L=900mm with grid
-Outer and inner wall plates
-Fastening accessories
B23 TYPE horizontal
HG0103 C2 011
Terminal includes:
-Rain protection
-Male/female extension L=1000mm
-Elbow 90°
B23 TYPE vertical
L1
15
14
29
28
L1
12
10
29
28
HG0103 C2 010
Max L1 of layout,
terminal excluded
Terminal Ø80 TB23-08-HS0
Pipes and elbows Ø80
Model
meters
RA015
30
RA024
30
RA032
29
RA035
26
RA043
22
RA054
17
Max L1 of layout,
terminal excluded
Terminal Ø80 TB23-08-HS0
Pipes and elbows Ø80
Model
meters
RA015
29
RA024
29
RA032
26
RA035
24
RA043
20
RA054
15
HG0109.12_ET_009-A
5.4
Terminal Layout
B23 TYPE
Open combustion circuit, combustion air intake from indoor, flue
are exhausted outdoor. In this case, UNI-CIG 7129 and 7131
rules require that suitable openings in the walls are provided.
REMARK: This layout requires an IP20 protection grid to be
installed. The grid [locations 28 and 29] must have a minimum
pitch of 8 mm and must prevent the inlet of any object with a
diameter greater than 12 mm into air intake.