background image

4

Part II. System Maintenance

RO-CTOP-C & RO-CTOP-PHC FILTER CHANGE SCHEDULE

FILTER CHANGE INSTRUCTIONS

Stage-1 & Stage-2           

Replace every

 6-8 months.

                                       
                                       

(Private well water source: may need to replace pre-filters sooner than

                                          8 months due to heavy sediments and other particles.)

Stage-3 Membrane:        City Water: 

Replace every

 2-3 years 

depending on input water

                                          quality, water usage, and pre-filters change maintenance.

                                       Private Well Water: 

Replace every

 2 years 

depending on well water

                                          quality, and pre-filters change maintenance.

Stage-4 Post-Filter:          For RO-CTOP-C System: 

Replace every

 2-3 years. 

It’s best to replace

                                          this filter when replacing the stage-4 membrane.

                                       For RO-CTOP-PHC System: 

Replace every

 6-12 months.

Important! 

It is important to change the 2 pre-filters timely, at least every 6-8 months. The pre-filters pro-

tect the stage-3 membrane. If they are not changed timely and become over-depleted, the membrane will 
be damaged and the RO system will be contaminated.

It’s best to use APEC replacement filters. Using “non-APEC” and lesser quality filters may clog up the RO 
system and damage the membrane.

2. Filter Ports:  

All filters have Quick-Connect ports. Remove and connect tubing to filter ports as shown 

in the “Quick-Connect Guide” diagram. (See 

Figure D1-D3 

in the next page).

 

1. Removing Case:  

The system comes with a premium case. The top half of the case will need to be re-

moved to replace the filters inside. To remove the top cover, you will need to remove the 

2 bottom screws 

ONLY

 on each end of the case. Please 

DO NOT

 remove the top 2 screws (See 

Figure C 

in the next page).

3. Removing Filters:  

Please change 

one filter at a time

 to avoid mixing up the filters. New filters come 

with 2” protective plugs on each end. You can take them out by pressing on the collet ring with one finger 
and using a pair of pliers or hand to pull out the protective tubing (See 

Figure D1 

in the next page).

The system requires very little maintenance. Just change the filter cartridges regularly as suggested below.
Keep the system indoors away from extreme hot or cold temperatures, and run the system within its reason-
able output capacity (i.e. allow the system to rest at least a few hours a day).

Pre-Filters:

Summary of Contents for RO-CTOP-C

Page 1: ...Countertop REVERSE OSMOSIS SYSTEM INSTALLATION INSTRUCTION OWNER S MANUAL All Rights Reserved APEC Water Systems www freedrinkingwater com Ver 1 0 ULTIMATE Models RO CTOP C RO CTOP PHC...

Page 2: ......

Page 3: ...ertop System To Your Faucet System Hook Up page 3 2 System Maintenance Filter Change Filter change schedule instructions page 4 How to Replace Stage 1 Filter page 6 How to Replace Stage 2 Filter page...

Page 4: ...nch pressure TDS Total Dissolved Solids contaminants PPM Parts Per Million unit used to measure TDS level TDS Meter A digital meter for measuring the TDS level in the water Copyright This manual is co...

Page 5: ...e to direct the water into the RO system See Point C Figure B Turn back knob Counter Clockwise to shut off water to the RO unit See Point D Figure B If input water is very cold you can adjust the fauc...

Page 6: ...filters Using non APEC and lesser quality filters may clog up the RO system and damage the membrane 2 Filter Ports All filters have Quick Connect ports Remove and connect tubing to filter ports as sh...

Page 7: ...the Quick Connect fitting then gently pull back on the tubing to make sure connection was secure No inserts sleeve or nuts are needed to secure the connection No Teflon tape To Disconnect See Fig D3 P...

Page 8: ...the 1st and 2nd stage filters to the top position Then do the following Step 1 Step 2 Remove the tubing lock red clip first Then disconnect the elbow fitting from Point D and dis connect tubing from...

Page 9: ...the Membrane Housing with Filmtec Membrane label on it 2 Disconnect tubing from the Membrane Housing Cap at Point I Remove membrane housing cap by turning it counter clockwise you can use membrane ho...

Page 10: ...nt K See Figure I To remove the Pure water output line first use a pair of pliers and remove the tubing lock red clip from Point K See Figure G Use a flat head screwdriver to push and hold the collet...

Page 11: ...rd the Tap water s reading Compare the 2 readings The Product water s TDS should be about 3 10 of your Tap water s TDS This is a normal range For example Your Tap water s TDS 100 ppm Your Product wate...

Page 12: ...ly on the input water pressure from your water pipe line The higher the feed pressure the faster the unit can produce water High pressure will also improve TDS rejec tion The chart above shows how dif...

Page 13: ...ty period in any manner or start a new warranty period Conditions of Validity of this Limited Product Warranty Even though the Product has extremely high endurance for operating conditions such as pH...

Page 14: ...uct or at the option of APEC return of the product and a refund of the purchase price Buyer assumes all risk whatsoever as to the result of the use of the product purchased whether used singularly or...

Page 15: ......

Page 16: ...ineering Corp 1320 S Johnson Drive City of Industry CA 91745 For questions or comments please visit our website at www freedrinkingwater com For technical support contact us at Techsupport freedrinkin...

Reviews: