10
RO-CTOP-C/ RO-CTOP-PHC Pure Water Production Rate
Input Water Pressure
Time to fill 8 oz cup
Time to fill 1 gallon jug
Gallons Per Day
60 psi
60 seconds
16 minutes
90 gpd
50 psi
72 seconds
19.2 minutes
75 gpd
40 psi
90 seconds
24 minutes
60 gpd
30 psi
120 seconds
32 minutes
45 gpd
* Production rate is based on input water temperature of 77 ºF.
* * * End of Owner’s Manual * * *
The RO-CTOP-C/ RO-CTOP-PHC runs solely on the input water pressure from your water pipe line. The
higher the feed pressure, the faster the unit can produce water. High pressure will also improve TDS rejec-
tion.
The chart above shows how different water pressure may effect the performance of the unit. Water pressure
can be determined by using a water pressure gauge. You can also use the pure water production rate as a
simple guide.
For example, it should take approximately 60 seconds to fill an 8oz cup at 60 psi. For very low water pressure,
an optional booster pump (sold separately) can be added to help increase the output rate of the system.