background image

impact  on  test  by  static  electricity  on  human  body;  the  tester  must  wear  anti-static  clothing, 

anti-static hat and anti-static shoes.   

 

The insertion depth of the φ5 diameter stainless steel mounting stem should not exceed the position 

of the detection gear switch on the back of the sensor.   

 

The surface of the φ5 diameter stainless steel mounting stem should have no insulation coating.   

 

During detection, please don’t touch the electrostatic detection probe.   

 

Ensure that the part of the sensor window is not polluted by particles and dust.   

 

There should be no shield between the sensor and the detected object; otherwise the accuracy of the 

detection result will be affected. 

 

There  should  be  no  electrical  equipment  that  affects  the  sensor  within  the  detection  range  of  the 

sensor; otherwise, failure and damage may be caused to the internal equipment and chip.   

 

To accurately measure the charged object, the plane of the sensor detection window must be parallel 

to the surface of the object being measured.   

 

Connect power supply for 5s before use; otherwise the data display may be unstable sometimes.   

 

When  the  charged  object  is  smaller  than  the  calibration  plate,  the  measured  value  will  be  smaller 

than the actual static value of the charged object.   

 

When the charged object is larger than the calibration plate, the measured value will be larger than 

the actual static value of the charged object. 

 

Don’t  set  zero  under  static  charge  state  or  in  static  measurement  process  (non-static  calibration 

process); if zero is set during static measurement, the displayed static value may be zero.   

 

Don’t  install  high  voltage  equipment  around,  such  as  high  voltage  power  supply,  electrostatic 

generator,  iron  generator  and  eliminator,  because  the  high  voltage will  affect  the  performance  and 

detection accuracy of the sensor.   

 

During  the  installation  of  high  vibration  area,  please  fasten  the  sensor,  otherwise  data  error  may 

occur.   

 

Please  regularly  check  the  power  cable/communication  cable  of  the  product  and  replace  it 

immediately  if  there  is  damage,  otherwise  problems  such  as  electric  leakage,  poor  communication 

and abnormal work may be caused.   

 

If the product suffers mechanical impact such as drop, collision and so on, it may cause failure. 

5.2. Warnings:   

 

The whole set of equipment must be reliably grounded during use; otherwise abnormality and even 

damage may be caused to the sensor.   

 

It’s forbidden to use the equipment in flammable and explosive environment.   

 

It’s forbidden to touch the electrostatic detection window with sharp object.   

 

The product is strictly prohibited to contact water stain; otherwise abnormality will be caused, thus 

leading to electric shock or fire.   

 

If the measurement range of detection is exceeded, it may cause product failure.   

 

During the inspection or replacement of product, turn off power, otherwise electric shock or fire may 

be caused.   

 

This detection instrument is a precision device, please don’t dismantle it.   

 

It’s forbidden to dismantle the product arbitrarily; internal maintenance and repair must be made 

by professional personnel.   

 

The  product  is  specially  designed  for  detecting  static  electricity  on  the  surface  of  the  object.  It  is 

strictly  prohibited  to  be  used  for  other  purposes.  Any  abnormal  use  may  cause  machine  failure, 

electric shock, fire and other hidden dangers. 

 

Summary of Contents for AP-YV3302H

Page 1: ...Electrostatic Sensor AP YV3302H Operating Instruction Shanghai Anping Static Technology Co Ltd Floor 3 Building 27 No 69 Guijing Road Shanghai China Tel 021 64517676 Fax 021 64517673 ...

Page 2: ...of Application It can be widely applied in the industries such as electronics photoelectricity and plastics III Product Features 1 With comfortable feel and beautiful appearance 2 Detection distance can be selected via dial switch 3 Wide detection potential range and high detection precision 4 Alarm threshold can be set and red light alarm indicatesexceeding threshold 5 High definition and all dim...

Page 3: ...ar and minimum resolution corresponding to each measuring distance Detection gear Detection distance coding Detection distance Measurement range Resolution Measuring error 1 0 5mm 2000V 1V 5 1 10mm 4000V 2V 2 25mm 10000V 5V 3 50mm 15000V 10V 4 100mm 20000V 10V 5 150mm 20000V 10V 6 200mm 20000V 15V 7 250mm 20000V 20V 2 8 300mm 20000V 10V 9 350mm 20000V 15V A 400mm 20000V 15V B 450mm 20000V 15V 3 C ...

Page 4: ...ay be changed Subject to the real product and please understand that notice cannot be given in advance 4 Technological function of infrared remote control command Blower Bar Sensor CAL SRZ VTH VTH K K IB IB T T FR S BR S FQ FQ IB IB FS FS RES For user SRZ reset zero VTH VTH threshold adjustment with step unit 10V Unlock 1 After unlocking 30seconds delay for active if any button is pressed 2 After ...

Page 5: ...ce of temperature and humidity on electrostatic detection The lower the temperature is the smaller the humidity is the less water is contained in the space and the more easily the surrounding object triboelectric and the greater the interference to the electrostatic detection is 1 The higher the temperature is the higher the humidity is the more water is contained in the space and the more active ...

Page 6: ...connection Temperature and humidity display LCD Monitoring setting of electrostatic sensor Setting of operating time of electrostatic eliminator Monitoring setting of electrostatic eliminator ACI AC indication on monitor green light is ON for long Network connection red light flashes and green light is ON for long Network disconnection red light flashes and green light is OFF 4 line status indicat...

Page 7: ...inal Overall dimension 100 120 25mm L W H Net weight of monitoring terminal about 400g The overall dimension of monitoring terminal is shown as follows 100 120 52 76 87 5 14 14 4 25 IMS Smart Controller WAN LAN P4 P3 P2 P1 POWER P1 P4 1 2 VCC 3 RS485_B 4 RS485_A 5 6 GND 7 C_V TH HVAL 8 C_ACT Clean 9 PE Metal shield P1 P2 P4 P3 Red VTH HVAL ACT Clean Green ACT Wrok Link NEXT SCAN NEXT LINK B SET S ...

Page 8: ...is shown as follows 输出端口 24V直流1 2线输出 三相电源插座 AC100 240V 50 60Hz Mechanical parameters of communication converter Overall dimension 90 28 22mm L W H Net weight of communication converter about 20 5g The overall dimension of communication converter is shown as follows 接口 接口 RJ45 output port 24V DC 1 2 line output Three phase power socket RJ45 port USB port ...

Page 9: ...ng temperature 0 50 Working humidity 30 65 RH VI Product Calibration 1 Calibration environmental conditions The calibration environmental conditions and requirements are as follows a Environmental temperature 20 5 b Relative humidity 30 60 c There is no measurable electrical field magnetic field as well as positive and negative irons around d There is ground wire and the resistance of ground is 10...

Page 10: ...ectrodes should be wrapped with insulating materials the plate area should be large enough and the diameter or side length should be no less than 0 4m Our calibration plate is square stainless steel plate with the dimension of 600mm 600mm R protective resistance the withstand voltage strength of resistance is 20KV and the current through the protective resistance and human body is 5mA and the resi...

Page 11: ...gure is the calibration voltage line when the slope is 1 10000 5000 0 5000 10000 10000 5000 0 5000 10000 标 准 电压 斜 率K 1 测试距离100mm 测试距离300mm 测试距离500mm 实测电压值 V 标 准 平板 电压值 V 1000 800 600 400 200 0 200 400 600 800 1000 1000 800 600 400 200 0 200 400 600 800 1000 实测电压值 V 标 准 平板 电压值 V 标 准 电压 斜 率K 1 测试距离100mm 测试距离300mm 测试距离500mm The following two figures are the test data maps under different horizontal t...

Page 12: ...m 200mm 250mm 300mm 350mm 400mm 450mm 500mm 550mm 600mm 700mm at this point the detection data displayed by the terminal is the most accurate Vertical test distance 500mm Actual measured voltage value Horizontal test distance Baseline Voltage Baseline Voltage Baseline Voltage Baseline Voltage Baseline Voltage Baseline Voltage Baseline Voltage Baseline Voltage Baseline Voltage Baseline Voltage Base...

Page 13: ... PC 一个串口可连接16台机器 静电传感器 静电传感器 静电传感器 转 通讯转换器 终端电源 网线 网线 3 Operating steps refer to the following attached drawings According to the static electricity quantity and the operating environmentof the charged object rotate the circular dial switch with the 3mmdiameter cross screwdriver to select the test distance According to the static electricity quantity and the operating environmentof the charged obj...

Page 14: ...otate the circular dial switch with the 3mmdiameter cross screwdriver to set the equipment address 4 Installation drawing Select test distance Static threshold alarm indicator light Select equipment address Select measurement range for test ...

Page 15: ...4 1 Structure chart of each mounting fixture ...

Page 16: ...re use Before power on please check the specification of the provided power supply Any power supply nonconforming to the specification will cause damage and even failure of product Please operate the product under the specified temperature 0 50 During test the distance between the person and the product should be more than 1m to avoid Φ5 diameter stainless steel mounting stem Round head knurled cr...

Page 17: ...e displayed static value may be zero Don t install high voltage equipment around such as high voltage power supply electrostatic generator iron generator and eliminator because the high voltage will affect the performance and detection accuracy of the sensor During the installation of high vibration area please fasten the sensor otherwise data error may occur Please regularly check the power cable...

Page 18: ...e good performance of the product please store the equipment in a dry place away from light when it s not used Please don t press it heavily 2 This equipment is a precision detector please don t vibrate it intensively during use X After sales Services AP YV3302H electrostatic sensor has received strict testing inspection and aging treatment before delivery and its performance can completely reach ...

Reviews: