53
TC5-1V6SA.rev.06
NOTES:
i) These initial parameter settings will not be retained in the controller's
memory. Each new setting will replace the preceding one.
ii) If the power supply is cut off, the last parameter settings will be
retained in memory until the power is restored.
FACTORY SETTINGS
P A R A M E T E R
F A C T O R Y
S E T T I N G
R A N G E O F
V A L U E S
T e m p e r a t u r e S e t P o i n t
7 5
o
F ( 2 3 . 9
o
C )
- 4 0 t o 9 9 . 9
o
F
( - 4 0 t o 3 7 . 7
o
C )
S t a g e 1
M i n i m u m
S p e e d
4 0 %
1 0 % t o 1 0 0 %
T i m e O n
1 5 s e c o n d s
0 t o 9 0 0 s e c o n d s b y
i n c r e m e n t s o f 1 5
s e c o n d s
T i m e O f f
0 s e c o n d s
B a n d w i d t h
2
o
F ( 1 . 1
o
C )
0 . 5 t o 2 0
o
F
( 0 . 3 t o 1 1 . 1
o
C )
H u m i d i t y
C o n t r o l
H u m i d i t y
S e t P o i n t
6 5 %
4 0 t o 1 0 0 %
r e l a t i v e h u m i d i t y
C o m p e n s a t i o n
P e r c e n t a g e
6 0 %
0 t o 1 0 0 % o f s t a g e 1
m i n i m u m s p e e d
S t a g e s 2
t o 7
D i f f e r e n t i a l
2
o
F ( 1 . 1
o
C )
0 . 5 t o 2 0
o
F
( 0 . 3 t o 1 1 . 1
o
C )
M i s t
T i m e O n
1 m i n u t e
0 t o 6 0 m i n u t e s , b y
i n c r e m e n t s o f 1
m i n u t e
T i m e O f f
1 0 m i n u t e s
0 t o 6 0 m i n u t e s , b y
i n c r e m e n t s o f 1
m i n u t e
O f f s e t
1 4
o
F ( 7 . 8
o
C )
0 . 5 t o 4 0
o
F
( 0 . 3 t o 2 2 . 2
o
C )
D i f f e r e n t i a l
2
o
F ( 1 . 1
o
C )
0 . 5 t o 2 0
o
F
( 0 . 3 t o 1 1 . 1
o
C )
H u m i d i t y T u r n
O f f L e v e l
9 5 %
4 0 t o 1 0 0 %
r e l a t i v e h u m i d i t y
H e a t e r O f f s e t
2
o
F ( 1 . 1
o
C )
- 1 0 t o 2 0
o
F
( - 5 . 6 t o 1 1 . 1
o
C )
M a x . T e m p e r a t u r e
D i f f e r e n c e B e t w e e n
Z o n e s
7 . 5
o
F ( 4 . 2
o
C )
5 t o 4 0 ° F
( 2 . 8 t o 2 2 . 2 ° C )
A l a r m s
H i g h O f f s e t
1 2 . 0
o
F ( 6 . 7
o
C )
0 . 5 t o 4 0
o
F
( 0 . 3 t o 2 2 . 2
o
C )
L o w O f f s e t
1 0 . 0
o
F ( 5 . 6
o
C )
0 . 5 t o 4 0
o
F
( 0 . 3 t o 2 2 . 2
o
C )