background image

The  Aoyue  Int732  Game  Console  Repairing  System  is  a  reworking  equipment 

that  utilizes infrared (IR)  heating technology, to  provide top  and  bottom  heating  to 

the  target  components.  It  is  equipped  with  a  versatile  board  holder,  Lead  free 

compatible solder  Iron,  and software  profile  control of  heating  in one  sophisticated 

package.  It  is  designed  for  reworking  double­sided,  diverse  technology  printed 

circuit boards (PCB) which  utilizes traditional or lead free solder. 

The  system  is  equipped  with  High  powered  IR­heating  elements  combined 

with  multiple  types  of  operating  mode  to  fit  various  task.  Finally,  the  unique, 

innovative design with digital control panel offers precision, safety, and ease of use 

to meet all reworking requirements.

 

PRODUCT DESCRIPTION 

 

Complete   Game   Console   Repairing   System.­Combines   large   area   bottom­ 

heater,  high  powered  top­heater  and  lead  free  compatible  solder  iron  in  one 

package. 

 

Three different types of operation to suite different needs: 

Type 0 – For re­balling or pre­baking the board. Uses internal sensors. 

Type 1 – Allows manual control of the rework process. Uses external sensors. 

Type 2 – Automated reflowing process utilizing the user configurable profile. 

 

Closed Loop Temperature Control with Three External Sensors 

—  Sensors  attached  to the  board  allows  precise temperature  control  at  board 

level  minimizing  damage  to  board  due  to  inaccurate  temperature  settings  or 

overheating.  Two  sensors  are  used  as  temperature  control  and  monitoring, 

while   an   extra   sensor   is   added   to   allow   additional   monitoring   of   other 

temperature sensitive areas of the PCB. 

 

Enhanced Top and bottom heater 

310 x 310 mm effective bottom heating area. 1500 watts of pre­heating power 

minimizes board warping. 

60 x 60 mm effective top heating area. 500 watts maximum heating power with 

various nozzles to fit different BGA sizes.

 

FUNCTIONS and FEATURES

 

13 

OPERATING PROCEDURES 

Note: 

During segments 1­3 the top heater heats up to 75% of the  set temperature 

at  these  segments.  This  is  to  allow  a  faster  ramp  up  in  preparation  for  reflow  for 

segments 4­6. 

1. 

To enter type “

2

” operation. Select 2 at the initial screen then press the select 

button. The display would change to “

Slct Prof  0

”. This signifies we are now 

in the type “

2

” mode. 

2. 

We  can  then  select  which  profile  we  would  like  to  use  by  pressing  the 

increase  or  decrease  button.  The  number  shown  at  the  bottom  display  will 

change corresponding to your selection. There are three stored and selectable 

profile. 

3. 

To  adjust  the  time  and  temperature  profile  of  each  segment  press  the 

selection button twice. The top display will show which segment “

SEG1

”  we 

are  currently  adjusting.  The  middle  display  will  show  whether  we  are 

adjusting the

 “dur” 

(duration/Time) or

 “tEMP” 

(temperature).  The bottom 

display shows the value we are currently adjusting. Its suffix

 “t

” signifies we 

are adjusting the time or temperature for a suffix “

C

”. 

4. 

Press  the  increase  or  decrease  button  to  adjust  the  desired  duration  and 

temperature.  The  set  temperature  is  adjustable  from  50  to  250  C  and 

duration  5 to 200 seconds. 

5. 

After the duration or temperature is set press the selection button to move to 

the  next  segment.  There  are  six  segments  available  each  with  its  own 

duration and temperature settings. The duration settings signifies the time it 

will take to reach our set temperature level. For example: if set duration is 50t 

and temperature is set at 100C. Then assuming the board temperature is 50C 

when the automated rework is initialized the system would gradually increase 

board  temperature  by  1  Degree  per  second  such  that  after  50  seconds  the 

board temperature would reach 100C. 

6. 

After  we  have  set  the  segments  of  the  profile  we  may  begin  automated 

reworking.  To  start  automation  repeatedly  press  the    selection  button  until 

the display shows the word

 “Run  Prof  0” 

(the bottom display number should 

correspond to the selected profile) then press the increase button. A 3 second 

countdown will commence before automated reworking starts.

Summary of Contents for Int732

Page 1: ...LAY AND OTHER DEVICE OPERATION ISSUES SOLUTION Turn off power and back on OTHER PROBLEMS NOT MENTIONED Contact the vendor AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY Jishui Industrial Zone Nantou Zhongs...

Page 2: ...6 SPECIFICATIONS 6 OPERATING PROCEDURES 7 15 BASIC TROUBLESHOOTING GUIDE 16 15 OPERATING PROCEDURES To check the slope from segment Two 150C 180C 30C Time to reach 150C is set to 110seconds Therefore...

Page 3: ...reloaded Profile 0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 090t 110t 150t 050t 060t 60t 150C 180C 210C 190C 210C 230C Segment one is set to 50 seconds to reach 150C Which means after 50seconds at the end of seg...

Page 4: ...te During segments 1 3 the top heater heats up to 75 of the set temperature at these segments This is to allow a faster ramp up in preparation for reflow for segments 4 6 1 To enter type 2 operation S...

Page 5: ...at the temperature set at segment 3 Then the last three segments utilizes the top heater to provide the final 25 of the heat to reach reflow 5 FUNCTIONS and FEATURES Multi Point Board Holder Innovativ...

Page 6: ...button repeatedly until the top display shows TOP and the middle display shows SEt The bottom display would show the current set temperature of the top heater followed by a suffix A 2 Press the incre...

Page 7: ...y a suffix C Note External temperature probes are labeled Top heater external probe is labeled A while the other two is labeled b and C The displayed actual temperature reading s suffix corresponds to...

Page 8: ...rature is adjustable from 200 to 480C 3 For the solder iron actual temperature display Follow TYPE 0 OPERATION number 5 see page 10 4 To temporarily turn off the solder iron Simultaneously press both...