SPECIFICATIONS*
Power Input:
Available in 110V 21Amps / 220V 11 Amps (Max)
Dimensions:
Main Unit:
520(l) x 370(w) x 410(h) mm
Board Holder:
450(l) x 280(w) x 134(h) mm
Power
Consumption:
Total :
2100 Watts Maximum
Top Heater:
500 Watts
Bottom Heater:
1500 Watts
Solder Iron:
75 Watts
Temperature Range:
50°C 280°C (^maximum)
Heating Element:
Top Heater:
Forced Convection Quartz Infrared
Bottom Heater:
Quartz Infrared
Solder Iron:
Ceramic heater
PreHeating Area:
Top Heater:
60 x 60 mm
Bottom Heater:
310 x 310 mm
Weight:
Approx. 11.6 Kg
^Depends on type of operation
*Specifications subject to change without prior notice
*** Expansion for future versions, may not be available for current releases.
Nozzles
Lamp
Notice ***
Vacuum Suction
Pen
Others:
Flux.
Spatula.
Temperature
probe
11
OPERATING PROCEDURES
This type of operation utilizes the external temperature
probe A
to regulate
the top heater, while the external temperature
probe b
regulates the heat of the
bottom heater. Using this type of operation allows us to closely control the
temperature at board level. While freeing up external temperature
probe C
for
additional monitoring.
1.
To set the desired top heater temperature press the selection button
repeatedly until the top display shows “
TOP
” and the middle display shows
“
SEt
” . The bottom display would show the current set temperature of the top
heater followed by a suffix “
A
”.
2.
Press the increase or decrease button to adjust the top heater set
temperature level. The set temperature is adjustable from 50 to 280 C in this
type of operation. To temporarily turn off the top heater simultaneously press
both the “Increase” and “decrease” button
(
#3
&
#4
from the control panel
display see page 8)
. The bottom display will show “OFF” indicating the top
heater is now turned off.
3.
To set the desired bottom heater temperature press the selection button
repeatedly until the top display shows “
bOt
” and the middle display shows
“
SEt
” . The bottom display would show the current set temperature of the
bottom heater followed by a suffix “
b
”.
4.
Press the increase or decrease button to adjust the bottom heater set
temperature level. The set temperature is adjustable from 50 to 280 C in this
type of operation. To temporarily turn off the bottom heater simultaneously
press both the “Increase” and “decrease” button
(
#3
&
#4
from the control
panel display see page 8)
. The bottom display will show “OFF” indicating the
bottom heater is now turned off.
5.
For this type
(type 1)
of operation we must closely monitor the actual
temperature of the Top heater external temperature
probe A
and the
external temperature
probe b.
As this two probes manage the heat of both