8
OPERATING PROCEDURES
A. INITIAL PROCEDURES
1.
Make sure all switches are deactivated.
2.
Attach external sensor probes to the three pin socket
(#6 on control panel
guide)
.
3.
Attach the Top Heater power cord (
#11
on control panel guide)
to the Top
heater power connector
(
#13
on control panel guide)
.
4.
Attach the Top heater sensor cord
(
#12
form the control panel guide)
to the
base connector
(
#14
from the control panel guide)
.
5.
Attach the device to the main power source. It is recommended to use NEMA
plugs and receptacles with ratings compliant to the machine specifications
(see page 6)
.
6.
To turn the unit ON. Toggle the main power switch to ON position
(
#8
on
control panel guide)
.
B. OPERATION TYPE(MODE) SELECTION
1.
Follow initial procedures,
“
A. INITIAL PROCEDURES
”
.
2.
The display would show “
TYPE 0
”, which means Type 0 operation will be
used. To select between types 0 to 2. Press the increase or decrease buttons
(
#3
&
#4
of control panel guide)
.
3.
To confirm selection and enter into operation mode using the selected
operation type. Press the selection button
(
#2
of control panel guide)
.
C. SOLDER IRON UNDER OPERATION TYPE 0 and 1
1.
To set the desired solder iron temperature press the selection button
repeatedly until the top display shows “
SEt
” and the middle display shows
“
iron
” . The bottom display would show the current set temperature of the
solder iron followed by a suffix “
F
”.
9
OPERATING PROCEDURES
2.
Press the increase or decrease button to adjust the set temperature level. The
set temperature is adjustable from 200 to 480C.
3.
For the solder iron actual temperature display. Follow
TYPE “0”
OPERATION
number 5
(see page 10)
.
4.
To temporarily turn off the solder iron. Simultaneously press both the
“Increase” and “decrease” button
(
#3
&
#4
from the control panel display
see page 8)
. The bottom display will show “OFF” indicating the solder iron is
now turned off.
D. TYPE “0” OPERATION
This type of operation utilizes the internal temperature sensors to control the
heat. Using this type frees up the three extra external temperature probes for
monitoring. Attach the three extra temperature probes to areas of interest such as
the bottom of the board and/or near the component to we worked on.
1.
To set the desired top heater temperature press the selection button
repeatedly until the top display shows “
TOP
” and the middle display shows
“
SEt
” . The bottom display would show the current set temperature of the top
heater followed by a suffix “
A
”.
2.
Press the increase or decrease button to adjust the top heater set
temperature level. The set temperature is adjustable from 50 to 550 C in this
type of operation. To temporarily turn off the top heater. Simultaneously
press both the “Increase” and “decrease” button
(
#3
&
#4
from the control
panel display see page 8)
. The bottom display will show “OFF” indicating the
top heater is now turned off.
Note: In order to reach the maximum
temperature it is recommended that a nozzle is attached.
3.
To set the desired bottom heater temperature press the selection button
repeatedly until the top display shows “
bOt
” and the middle display shows
“
SEt
” . The bottom display would show the current set temperature of the
bottom heater followed by a suffix “
b
”.