background image

OPERATING PROCEDURES 

A.  INITIAL PROCEDURES 

1. 

Make sure all switches are deactivated. 

2. 

Attach  external  sensor  probes  to  the  three  pin  socket

  (#6  on  control  panel 

guide)

 . 

3. 

Attach the  Top Heater power  cord (

#11 

on control panel guide)

 to  the Top 

heater power connector

 (

#13 

on control panel guide)

 . 

4. 

Attach the Top heater sensor cord

 (

#12 

form the control panel guide)

 to the 

base connector

(

#14 

from the control panel guide)

 . 

5. 

Attach the device to the main power source. It is recommended to use NEMA 

plugs  and  receptacles  with  ratings  compliant  to  the  machine  specifications

 

(see page 6)

 . 

6. 

To  turn  the  unit  ON.  Toggle  the  main  power  switch  to  ON  position

  (

#8 

on 

control panel guide)

 .

 

B.  OPERATION TYPE(MODE) SELECTION 

1. 

Follow initial procedures,

 “

A. INITIAL PROCEDURES

2. 

The  display  would  show  “

TYPE  0

”,  which  means  Type  0  operation  will  be 

used. To select between types 0 to 2. Press the increase or decrease buttons

 

(

#3 

&

 #4 

of control panel guide)

 . 

3. 

To  confirm  selection  and  enter  into  operation  mode  using  the  selected 

operation type. Press the selection button

 (

#2 

of control panel guide)

 .

 

C.  SOLDER IRON UNDER OPERATION TYPE 0 and 1 

1. 

To  set  the  desired  solder  iron  temperature  press  the  selection  button 

repeatedly  until  the  top  display  shows  “

SEt

”  and  the  middle  display  shows 

iron

”  .  The  bottom  display  would  show  the  current  set  temperature  of  the 

solder iron followed  by a suffix “

F

”.

 

OPERATING PROCEDURES 

2. 

Press the increase or decrease button to adjust the set temperature level. The 

set temperature is adjustable from 200 to  480C. 

3. 

For  the  solder  iron  actual  temperature  display.  Follow

  TYPE  “0” 

OPERATION 

number 5

 (see page 10)

 . 

4. 

To  temporarily  turn  off  the  solder  iron.  Simultaneously  press  both  the 

“Increase”  and  “decrease”  button

 (

#3 

&

  #4 

from  the control  panel  display 

see page 8)

. The bottom display will show “OFF” indicating the solder iron is 

now turned off.

 

D.  TYPE “0”  OPERATION 

This type of operation utilizes the internal temperature sensors to control the 

heat.    Using  this  type  frees  up  the  three  extra  external  temperature  probes  for 

monitoring.  Attach the three  extra  temperature  probes to areas of interest  such  as 

the  bottom of the board and/or near the component to we worked on. 

1. 

To  set  the  desired  top  heater  temperature  press  the  selection  button 

repeatedly  until  the  top  display  shows  “

TOP

”  and  the  middle  display  shows 

SEt

” . The bottom display would show the current set temperature of the top 

heater followed  by a suffix “

A

”. 

2. 

Press  the  increase  or  decrease  button  to  adjust  the  top  heater  set 

temperature level. The set temperature is adjustable from 50 to  550 C in this 

type  of  operation.    To  temporarily  turn  off  the  top  heater.  Simultaneously 

press both the “Increase” and “decrease” button

 (

#3 

&

 #4 

from the control 

panel display see page 8)

. The bottom display will show “OFF” indicating the 

top  heater  is  now  turned  off.

  Note:  In  order  to  reach  the  maximum 

temperature it is recommended that a nozzle is attached. 

3. 

To  set  the  desired  bottom  heater  temperature  press  the  selection  button 

repeatedly  until  the  top  display  shows  “

bOt

”  and  the  middle  display  shows 

SEt

”  .  The  bottom  display  would  show  the  current  set  temperature  of  the 

bottom heater followed  by a suffix “

b

”.

Summary of Contents for Int732

Page 1: ...LAY AND OTHER DEVICE OPERATION ISSUES SOLUTION Turn off power and back on OTHER PROBLEMS NOT MENTIONED Contact the vendor AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY Jishui Industrial Zone Nantou Zhongs...

Page 2: ...6 SPECIFICATIONS 6 OPERATING PROCEDURES 7 15 BASIC TROUBLESHOOTING GUIDE 16 15 OPERATING PROCEDURES To check the slope from segment Two 150C 180C 30C Time to reach 150C is set to 110seconds Therefore...

Page 3: ...reloaded Profile 0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 090t 110t 150t 050t 060t 60t 150C 180C 210C 190C 210C 230C Segment one is set to 50 seconds to reach 150C Which means after 50seconds at the end of seg...

Page 4: ...te During segments 1 3 the top heater heats up to 75 of the set temperature at these segments This is to allow a faster ramp up in preparation for reflow for segments 4 6 1 To enter type 2 operation S...

Page 5: ...at the temperature set at segment 3 Then the last three segments utilizes the top heater to provide the final 25 of the heat to reach reflow 5 FUNCTIONS and FEATURES Multi Point Board Holder Innovativ...

Page 6: ...button repeatedly until the top display shows TOP and the middle display shows SEt The bottom display would show the current set temperature of the top heater followed by a suffix A 2 Press the incre...

Page 7: ...y a suffix C Note External temperature probes are labeled Top heater external probe is labeled A while the other two is labeled b and C The displayed actual temperature reading s suffix corresponds to...

Page 8: ...rature is adjustable from 200 to 480C 3 For the solder iron actual temperature display Follow TYPE 0 OPERATION number 5 see page 10 4 To temporarily turn off the solder iron Simultaneously press both...