background image

4  

FUNCTION and FEATURES 

● 

Microprocessor-controlled ESD safe equipment. 

● 

Switchable temperature readout between Fahrenheit and 
Centigrade.

 

● 

Fast heating response with built-in thermal protector 

● 

Built-in temperature sensor that aids in providing stable 
(temperature) measurements. 

● 

Integrated airflow gauge for precise airflow level adjustment 

● 

Digital control and display of hot air temperature and air pressure. 

● 

User configurable sleep mode for additional device protection 
and power saving. 

● 

Built-in auto-cooling process that protects the system and its 
components from excessive heat, prolonging usage life. 

● 

Compatibility with air nozzles of various types.  

PACKAGE INCLUSIONS 

* Type of soldering tip included might change  depending  on availability. 
** Kindly refer to soldering iron stand installation insert for parts and 
instructions. 

QUANTITY 

PART DESCRIPTION 

1 unit 

 Main Station with Hot Air Gun

 

4 pcs 

 Air Nozzles

 (

1124

1130

1196

1197

1 pc 

 Z003 Hot Air Gun Holder 

1 pc 

 Vacuum Suction Pen 

For

 

 

pro

only 

1 pc 

 G001 IC Popper (for + pro) 

1 pc 

 Power Cord 

1 pc 

 Instruction Manual 

 13 

G.  Line Frequency Selection 
 

By default, the system's line frequency has been programmed 

from the factory but for some cases when a manual override of the 
line frequency is needed the following procedure can be done. 

1. Follow System Setting  procedures 1 to 6. Adjust system 

selection menu to “SEL 4”, then press the air flow control up 
button  “C3”. 

2. If successful the display “B2” would show “-50” indicating 

frequency  is being set. 

3.  Adjust the frequency with the air flow control  buttons  “C3 and 

C4”. Select “-50” for 50 Hz and select “-60” for 60 Hz. 

4.  Save the selected settings and exit from the frequency selection 

menu by pressing the Hot Air gun function switch “F” . 

 

H.  Utilizing the Hot Air Gun Digital Temperature Calibration 
 

By default, the system is properly calibrated but for some cases 

when a little adjustment of the Hot Air Gun temperature is required 
the following procedure can be done. 

1. Follow System Setting  procedures 1 to 6. Adjust system 

selection menu to “SEL 4”, then press the air flow control up 
button  “C3”. 

2.  If successful the display would show “ Add 000” indicating hot air 

gun digital calibration is being set. 

3.  Adjust the offset value with the air flow control buttons “C3 and 

C4”, the word “Add” signifies a positive calibration value while the 
word “Sub” signifies a negative calibration value. Value is 
adjustable from –50 to 90 degrees with “000” signifying no offset. 

4.  Save the selected calibration settings and exit from the calibration   

adjustment menu by pressing the Hot Air gun function switch “F” . 

5.  Enter hot air gun function and set to desire temperature to check 

if additional calibration is needed.  

OPERATING GUIDELINES 

Summary of Contents for Int 852A++ pro

Page 1: ...ttp www aoyue com SMD Rework Station INSTRUCTION MANUAL Thank you for purchasing Aoyue int 852A pro int 852A pro SMD Rework Station It is important to read the manual before using the equipment Please...

Page 2: ...shooting Guide 14 Air Nozzles 15 This manual is designed to familiarize and instruct the op erator with the proper usage and maintenance of the equipment The Care and Safety Precautions section explai...

Page 3: ...enter of the base of the main unit has been removed This holds the pump in place during transportation and needs to be removed before using the equipment PROBLEM 6 UNIT SHOWS UNCONVENTIONAL BEHAVIOR D...

Page 4: ...needed the following procedure can be done 1 Follow System Setting procedures 1 to 6 Adjust system selection menu to SEL 4 then press the air flow control up button C3 2 If successful the display B2 w...

Page 5: ...y please observe the ff precautions Check each component after opening the package to make sure everything is in good condition If there are any suspected damage do not use the item and report the iss...

Page 6: ...t 60 indicating soldering iron sleep timer setting is being set 4 Adjust the sleep timer with the air flow control buttons C3 and C4 Sleep timer is adjustable from 5 to 60 minutes with t OFF signifyin...

Page 7: ...ing the procedures below 1 Turn off unit 2 Ensure that the Hot Air gun function switch F is in the ON position 3 Power ON unit by switching the power switch to ON 4 While the AOYUE name is scrolling s...

Page 8: ...the air flow level using the airflow control buttons C3 and C4 from the control panel 5 Adjust the hot air gun air temperature using the temperature control buttons C1 and C2 from the control panel T...

Reviews: