OPERATING GUIDELINES 

Auto­sleep  mode 

—  unit  is  also  programmed  to  have  an  auto­sleep 

mode, this is activated when hot air gun is turned on but is placed on the 

hot   air   gun   holder   and   not   put   to   use   for  set   amount   of   minutes, 

temperature  automatically  decreases  and  eventually  turns  to  sleep  mode. 

When  the  handle  is  held  up  again  the  unit  will  go  back  to  its  previous 

setting.

 

Sleep Mode Timer Set­Up 

1.  Switch the unit ON (or press “Reset” button,  from the panel). 

2.  Press  and  hold  hot  air  gun  up  button,  while  the  Name  and  model  is 

displayed. 

3.  Display  panel,  will  initially  indicate  ‘­0

’,  which  means  the  device  will 

switch  to  sleep  mode  after

  5 

minutes  (default)  of  idle  time  and  if  the 

nozzle is docked on the handle for the duration of time. 

4.  Adjust  the  time  before  sleep  by  pressing  air  pressure  up  and  down 

buttons. 

5.  Press Hot air gun down button to confirm. 

6.  The device will start counting down when the hot air gun is docked on 

the handle. Once countdown is finished and the hot air gun still docked, 

the  device  will  automatically  blow  air  (at  room  temperature)  to  bring 

down temperature to 90 

C. The panel will then display four dashes “­ ­ ­ 

­ “ to indicate that the device is now in sleep mode.

 

NOTES: 

 

Time is configurable from 1 to 20 minutes (default 5 minutes). 

 

The device has a switch located at the handle (cradle), which activates 

the countdown before the system goes to sleep. 

 

Once the hot air  gun is released from the handle during sleep mode, 

the   unit   will   automatically   switch   back   to   previous   working 

temperature and airflow level parameters. 

 

Timer  settings  defaults   back  to  5  minutes  every  time  the  unit  is 

powered down or the reset button is pushed. 

11

 

OPERATING GUIDELINES 

B. HOT AIR GUN 

1.  Switch ON the equipment by activating main power switch (9). 

2.  Activate HOT AIR GUN function switch (15) from the right side of the 

control panel. 

3.  The  system  will   immediately   blow  air  from  the  hot  air  gun  while 

gradually increasing  the  air  temperature  to  the  default  value  of  99°C. 

The ball inside the air gauge will also settle somewhere in the middle of 

the  visible  area,  corresponding  to  an  air  pressure  level  of  50.  The 

display  area  for  hot  air  temperature  and  air  pressure  level,  items  11 

and  12,  respectively,  will  show  the 

following. 

4.  Adjust air pressure using the AIR PRESSURE control buttons (3). 

5.  Adjust hot air temperature using the HOT AIR GUN temperature control 

buttons (2).

 Note: 

When increasing or decreasing the air temperature, 

the  prefix  of  the  display  area  for  hot  air  gun  temperature  (11)  will 

temporarily  change  from  uppercase  “H”  to  lowercase  “h”,  indicating 

that

  heat 

is  being  adjusted.  Once  the  buttons  are  released,  it  will 

switch   back   to   its   original   case   while   the   temperature   value   also 

gradually  increases  or  decreases  and  until  the  desired  temperature  is 

reached.

Summary of Contents for INT 738

Page 1: ...n complete handle 20170 1 Soldering Iron Tip enclosure SPARE PARTS LIST Manufacturer AOYUE TONGYI INTERNATIONAL LIMITED Jishui Industrial Zone Nantou Zhongshan City Guangdong Province P R China http w...

Page 2: ...he equipment The Care and Safety Precautions section explains the hazards of using any type of soldering or reworking device Please read carefully and observe the guidelines in order to maximize usage...

Page 3: ...Spare Parts List 5 Specifications 6 Functions Features 7 Safety Precautions 7 Operating Guidelines Control Panel 8 Assembly and Preparation 9 Startup procedures 10 Hot Air Gun 11 Soldering Iron 15 DC...

Page 4: ...r source If the voltage level falls significantly low about 15 20 lower than the standard there will also be a noticeable drop in the air pressure level SOLUTION Please refer to your local power servi...

Page 5: ...splay a blinking OFF on panel SOLUTION The heating element may be broken and needs to be replaced PROBLEM 4 THE UNIT IS VIBRATING TOO MUCH Check if the 4 screws that hold the pump in place are properl...

Page 6: ...g in the hand piece conduct the following test If any of the above mentioned combination registers a short review the steps in replacing the heating element to ensure proper connections CARE and MAINT...

Page 7: ...oard 8 Solder one RED wire of heating element with RED wire on PCB CARE and MAINTENANCE 7 CAUTION Improper usage can cause serious injury to personnel and or extensive damage to equipment and working...

Page 8: ...ture use a damp sponge to clean the tip and check for damages 3 If the tip has oxidation apply solder and wipe using the damp sponge repeat these steps until oxidation is removed 4 After cleaning coat...

Page 9: ...during soldering is already filtered IMPORTANT Filters should be cleaned and replaced regularly so that it would not clog up the air path and will effectively clean the toxic fumes produced during so...

Page 10: ...n switch 16 from the panel Set the time by using the up down rework time button 4 from the panel It is preset at 300 seconds 3 After preferred automate rework time has been set Turn on the hot air gun...

Page 11: ...ed at the handle cradle which activates the countdown before the system goes to sleep Once the hot air gun is released from the handle during sleep mode the unit will automatically switch back to prev...

Page 12: ...ld be set accordingly working with low airflow and high temperature often causes heating element to get easily burnt 13 OPERATING GUIDELINES Auto cool off function 1 When reworking is complete return...