50
7. Wire feeding speed indicator
When the indicator lights up, the left display shows the wire feeding speed (M/min).
8. Welding current indicator
When the indicator lights up, the left display shows the preset or actual welding current
values.
9. Sheet thickness indicator
When the indicator lights up, the left display shows the preset sheet thickness.
10. “a” dimension indicator
When the indicator lights up, the left display shows “a” dimension.
11. Parameters selection button 1
Select parameters from following for adjustment:
- “a” dimension
- Sheet thickness
- Welding current
- Wire feeding speed
- Peak current/Inductance
12.Parameters selection button 2
Select parameters from following for adjustment:
- Temperature indicator for the mains
- Arc length adjustment
- Welding voltage
- Welding speed
- Job (Channel) No
13.Parameter adjustment knob 1
Adjust values of “a” dimension, sheet thickness, preset current peak current and
inductance.
14.Parameter adjustment knob 2
Adjust values of preset voltage, arc length,Job No.
5-4 Structure