17
To read:
LP<CR>
Response:
LPn
2-8-14 HIGH PASS FILTER
HP
HPn
(n: 0 ~ 2) (default: 0)
0: Thru
1: 300Hz
2: 600Hz
To read:
LP<CR>
Response:
LPn
2-9 SQUELCH
2-9-1 LEVEL SQUELCH (RQ COMMAND)
The RQ command is used to automatically set squelch level according to the receive frequency.
(i.e. if the receive frequency is below 25 MHz, then squelch will be set to HF band.)
RQ
RQnnn
RQnnn.n
(nnn: 000 ~ 255)
(nnn.n: 0.0 ~ 140.0 (dB))
To read:
RQ<CR> or RQ.<CR>
Response:
RQannn (a: + or <SP>)
+: Squelch opens at the set level
<SP>: Squelch closes at the set level
RQannn.n (a: + or <SP>)
+: Squelch opens at the set level
<SP>: Squelch closes at the set level
Unit: dB
2-9-2 LEVEL SQUELCH (HQ COMMAND)
The HQ command is used to set squelch level for HF band and V/UHF band simultaneously.
HQ
HQuuu<SP>hhh
or
HQuuu.u <SP>hhh.h
uuu: UHF squelch level (uuu: 000 ~ 255)
hhh: HF squelch level (hhh: 000 ~ 255)
uuu.u: 000.0 ~ 140.0 (dB)
hhh.h: 000.0 ~ 140.0 (dB)
To read:
HQ<CR> or HQ.<CR>
Response:
HQ
HQuuu<SP>hhh
HQ.
HQuuu.u<SP>hhh.h (dB)
All manuals and user guides at all-guides.com