38
4-1-2 STARTING PRIORITY RECEIVE
PO
POn
: n: 0, 1
0: Priority Off (default)
1: Priority On
To read:
PO<CR>
Response:
POn
4-2 STEP ADJUST
SH
SHnnnnnn
: nnnnnn: (in Hz) Range:0 ~ 999.999 kHz
(default: 000.000)
To read:
SH<CR>
Response:
SHnnnnnn
4-3 SUB FREQUENCY STEP (FOR SUB DIAL)
SJ
SJx
: x: 0 ~ A ( in Hex.) (default: 0)
0: Same with main dial step frequency
1: x 10
2: 100Hz
3: 500Hz
4: 1kHz
5: 5kHz
6: 10kHz
7: 50kHz
8: 100kHz
9: 500kHz
A: 1000kHz (1MHz)
To read:
SJ<CR>
Response:
SJx
5 SPECTRUM DISPLAY
5-1 START FREQUENCY
TF
TFnnnnnnnnnn
: nnnnnnnnnn (Hz)
(default: 83.000) (MHz)
To read:
TF<CR>
Response:
TFnnnnnnnnnn
All manuals and user guides at all-guides.com