Circuit conditions
>
DN (Black)
DP (Red)
24V (Green)
0V (White)
DN (Black)
DP (Red)
24V (Green)
0V (White)
4-wire (isolated) ASLINKER
(Power supply of the AnyWire system)
Load driven by
an external power supply
4-wire (isolated)
ASLINKER
(Power supply of the AnyWire system)
Load driven by
an external power supply
[Configuration and Electrical Characteristics of the Input and Output Circuits]
<
Circuit conditions
>
Rated input voltage:
Max. switching current:
ON current:
OFF current:
ON voltage:
OFF voltage:
Allowable current at 24V:
24V DC
3.5mA
2.2mA or more
1mA or less
16V or more (24V-IN)
8V or less (24V-IN)
500mA max. (24V-0V)
(per terminal)
Withstand voltage:
Max. ON current:
30V DC
100mA
DN (Black)
DP (Red)
24V (Green)
0V (White)
To connect
inductive load, use
a surge killer.
If output is turned
ON with the 24V
and OUT terminals
short-circuited,
the output device
will be damaged.
To connect loads (e.g. I/O ports) that
are controlled with a power supply
other than the one used for the
AnyWireASLINK system, always use a
4-wire (isolated) terminal.
Otherwise, malfunction may be caused.
[E.g.]
Use the device by connecting the 0V
lines together.
DN (Black)
DP (Red)
24V (Green)
0V (White)
Switch, sensor, etc.
(2-wire type)
To connect loads (e.g. I/O ports) that
are controlled with a power supply
other than the one used for the
AnyWireASLINK system, always use a
4-wire (isolated) terminal.
Otherwise, malfunction may be caused.
[E.g.]
Use the device by connecting the 0V
lines together.
CAUTION
4-wire (isolated) NPN output
CAUTION
Load
Inter
nal cir
cuit
Inter
nal cir
cuit
Contr
ol cir
cuit
Inter
nal cir
cuit
Inter
nal cir
cuit
Contr
ol cir
cuit
4-wire (isolated) NPN input
BL287SB-02F-CC20 / BL287XB-02F-CC20 (Input)
BL287PB-02F-CC20 / BL287XB-02F-CC20 (Output)
6.8k
24V (Brown)
IN (Black)
24V (Brown)
OUT (Black)
0V (Blue)
6.8k
24V (Brown)
24V
OUT
0V
IN (Black)
24V (Brown)
24V
OUT (Black)
IN
0V (Blue)
-BL287*B02F*CC20 12/16-