BL287SB-02F –

BL287PB-02F –

BL287SB-02FS –

Brown: 24V
Black: OUT

BL287XB-02F –

Brown: 24V
Black: OUT

BL287XB-02FS –

BL287PB-02FS –

LINK

ALM

Brown: 24V
Blue: 0V
Brown: 24V
Black: OUT

Brown: 24V
Blue: 0V

Brown: 24V
Black: IN
Blue: 0V

Brown: 24V
Black: IN
Blue: 0V

Black: OUT
Blue: 0V

Address setting

Address setting

Common procedure for address writer operation

[Various Settings]

Be sure to connect to the AnyWireASLINK master unit to use. 
ARW-04 (address writer) of Rev. (Ver.) 1.01 or later version, or ARW-03 of Rev. (Ver.) 
2.10 or later version is required for address setting. 
For the details of the operating method, refer to the product guide of the address writer.

Connect this unit to the AnyWireASLINK master unit. 
Set an address with the address writer with the transmission 
signal (DP/DN) and power supply (24V/0V) being connected.

An address number is set as a beginning number from which part of the transmission frame is occupied to the terminal. 
Set the address number within the range of bit address “0 to 254.”
(For the input/output mixed type, the same address number should be assigned to both input and output.)

- Set the address number so that the area occupied by the terminal does not exceed the transmission points of the master unit. 
- Make sure that the address number setting is not duplicated. 
- Also, use the address writer to read an address number that has been written in the terminal.

While power is supplied, make sure that 
the above lines are not short-circuited. 
Short-circuiting the lines may cause a 
fault of the unit. 

Black: DN

Red: DP

White: 0V

24V DC

*

For the power supply to be 

connected, be sure to use 

a 24V DC stabilized 

power supply.

AnyWireASLINK
master

CAUTION

Transmission
signal

Lot No. 19ECBNB

The factory-set address is “bit address 255” or “bit address 511,” which indicates that an address 

has not been set.

The factory-set address varies depending on lot No., as follows:

For S/W version “B” or later version: Bit address 511

For S/W version “A” or 3-digit lot No.: Bit address 255

Input and output operations are disabled with the factory-set address.

S/W version

CAUTION

Example:

Green: 24V

Summary of Contents for BL287PB-02F-CC20

Page 1: ...a potentially hazardous situation which if not handled correctly may result in personal injury or property damage CAUTION WARNING System power supply Use a stable 24V DC power supply Use of an unstab...

Page 2: ...Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Singl...

Page 3: ...fied replacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified repla...

Page 4: ...s PNP input 1 point output 1 point Function 4 This terminal can be used in connection to the AnyWireASLINK unit for word transmission Note that this terminal cannot handle word data by setting a word...

Page 5: ...Connect AnyWireASLINK AnyWireASLINK terminator One terminator should be connected to the DP DN terminal farthest from the AnyWireASLINK master unit Connect it correctly so as not to set the wrong pol...

Page 6: ...of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted regardless of whether power is supplied to all terminals collectively from the power supply for the...

Page 7: ...all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC stabilized power supply General purpose power supply filter Use it if necessary 2 wire terminal 2 wire terminal 4 wire terminal 2...

Page 8: ...dicator Red Brown 24V Black IN Blue 0V Input PNP Black OUT0 Blue 0V NPN Brown 24V Black OUT0 Black OUT1 Blue 0V Brown 24V Black OUT1 PNP Black OUT Blue 0V NPN Brown 24V Black OUT Output Input output m...

Page 9: ...e address number within the range of bit address 0 to 254 For the input output mixed type the same address number should be assigned to both input and output Set the address number so that the area oc...

Page 10: ...lified replacement function fails This operation occurs on the S W version B or later version 3 If ID duplication is detected when the master unit executes automatic address recognition this indicatio...

Page 11: ...t will be in the range from 21 6 to 27 6V Recommended voltage is 26 4V Check the total length Review the total length and wire diameter of transmission line so that the load will not exceed the curren...

Page 12: ...e output device will be damaged To connect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Otherw...

Page 13: ...circuited the output device will be damaged To connect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated ter...

Page 14: ...of conductive substances in the environment where the device is used Pollution level 2 means the occurrence of only pollution by non conductive substances In such an environment however electrical co...

Page 15: ...ADP 87 Mounting adaptor 23 2 4 2 4 80 8 20 2 n 1 40 2 4 4 2 6 15 2 3 5 20 2 11 5 5 R 1 2 1 5 1 7 7 5 3 5 BL287 B02F CC20 15 16 Connection hook Connection hook...

Page 16: ...ted in Japan 2013 2014 2017 2018 2019 2020 UMA 08833AM EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website...

Reviews: