The home screen is divided into 4 parts: Title Bar (left column), Power Metering (upper right), Block
Diagram (middle right) and Status Bar (lower right), as shown below.
Title Bar
: Shown in the picture above, the “Home” button is highlighted, indicating the Home screen
is now displayed. This screen is a touch screen. You may navigate to the other screens (Config, Status,
Help) by simply touching the coresponding button in the Title Bar.
Power Metering
ON/OFF (Green) Button : Provides TX ON/OFF control. When GREEN (as shown above), this
indicates the TX is ON. When RED, this indicates the TX is OFF.
FWD: Forward Power Meter. Touching the white display box of FWD will toggle its display
units between “dBm” and “W”.
REFL: Reflected Power Meter. Touching the white display box of REFL will toggle its display
units between “dBm” and “W”.
VSWR: Voltage Standing Wave Ratio
Status Bar
: During normal operation, the default status is “RUNNING OK”. If there is any alarm, the
alarm will show up in the Status Bar of each screen.
Block Diagram
: Press the “Exc A/B” graphic to navigate to the Dual Exciters Switching screen
(shown below). This screen shows which exciter is currently on-air (highlighted GREEN) and allows
the user to manually change the on-air exciter.
Summary of Contents for PA-VIII1-C-FA
Page 1: ...ANYWAVE PA VIII1 C FA User Manual Version 1 0 June 25 2018...
Page 11: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 11 of 27...
Page 13: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 13 of 27...
Page 22: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 22 of 27...
Page 24: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 24 of 27...
Page 26: ...PA U01 C FA User Manual ACT PAVIII1 USR DOC V1 0 06 25 2018 Page 26 of 27 3 3 5 HELP SCREEN...