20
master config file can then be modified and loaded back into the system or any segment
that needs to be reconfigured.
7.1.2 Reset Command
To reset a configuration to factory defaults, use the following command format:
256,x<,i><CR>
Where:
•
256
is the reset command
•
x
is the configuration line type code
•
<,i>
is an optional index that is a function of the line type code
•
<CR>
is a line terminating carriage return
Some examples using the RESET command:
Examples:
256,1<CR>
Reset Site config
256,6,2<CR>
Reset Serial Port 2 config
256,256<CR>
Reset System config
CAUTION USING THIS COMMAND:
This may reset the serial port in use.
Communications with the unit could be
lost.
7.1.3 Global Command
The global command can be used to set the same parameter to the same value, within
the same configuration type, for multiple indexes. The global command only works
with Geo-Fence, Channel, Schedule, Report Flags, and J1939 configuration types.
The global command format is:
257,x,i-j,y,zzzz<CR>
Where:
•
257
is the global command
•
x
is the configuration line type code
•
i
is a required starting index
•
j
is a required ending index, greater than
i
(NOTE: the range of indexes from
i
to
j
is inclusive and by definition are sequential)
•
y
is a parameter code identifying the configuration parameter that follows
•
zzzz
is the configuration parameter (this parameter could be an integer, a
floating point number, or a text string as defined by the parameter code
y
)
Summary of Contents for Messenger 600
Page 1: ...Messenger 600 User s Guide Version 1 0 0 May 13 2020 ...
Page 2: ...2 ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 39: ...39 ...