EGG STATION DUAL ZONE
12
P/N 1011416 Rev. H 02/18
McDonald’s
TROUBLESHOOTING (continued)
Hi Limit Control
The ESDZ-1200 has two Hi Limit resets - one for the front
cooking surface and one for the rear cooking surface. If a Hi
Limit trips, the display will show:
•
Error 14 for the rear cooking surface
•
Error 19 for the Front cooking surface.
A tripped Hi Limit shuts off power to the unit. To reset a
tripped Hi Limit switch:
1. Allow the unit to cool for 10 - 15 minutes
2. Note the error code to determine which Hi Limit has
tripped. The Hi Limit switches are located on the rear of
the unit and labeled
F
for Front and
R
for rear.
3. Remove both black protective cap from both Hi Limit
Switches. Press and release both buttons. Reinstall the
protective caps.
4. Turn the unit back on.
NOTE: If the Hi Limit Controls require continuous reset-
ting, contact Antunes Technical Service at +1-877-392-
7854 (toll free).
Figure 5. Hi Limit Control
Factory Reset
If required, the ESDZ-1200 can be reset to factory
defaults. Follow these steps to reset the unit:
1. Turn the unit off.
2. Press and hold the
Up
and
Down
arrow buttons
simultaneously. With the buttons held, press and
release the
Power
button. Continue holding the
Up
and
Down
arrow buttons.
3. When the display shows
Fr
(Factory Reset),
release the buttons. The unit is now reset to fac-
tory default settings.
Error Codes
This section describes the error codes that may appear on the
display.
NOTE: For the errors below, attempt to turn the unit
off and turn it back on again to see if the problem
is fixed. If the problem persists, refer to the Action
column.
Error
Description
Action
1 - 9
Probable circuit board
issue.
Contact Antunes
Technical Service
at +1-877-392-7854
(toll free) for assis-
tance.
10
Board temperature sensor
exceeds 158° F. The unit
shuts down.
Contact Antunes
Technical Service
at +1-877-392-7854
(toll free) for assis-
tance.
11
Rear heat is too low, or not
reaching setpoint tempera-
ture within 30 minutes.
12
Rear Heater not operating
13
Rear thermocouple defec-
tive
14
Rear Hi Limit tripped
Reset the Rear Hi
Limit switch.
15
Bad front Solid State Relay Contact Antunes
Technical Service
at +1-877-392-7854
(toll free) for assis-
tance.
16
Front heat is too low, or not
reaching setpoint tempera-
ture within 30 minutes.
17
Front Heater not operating. Check power outlet
for proper voltage,
try plugging unit into
a different outlet.
Reset both Hi-Limit
switches.
18
Front thermocouple defec-
tive
Contact Antunes
Technical Service
at +1-877-392-7854
(toll free) for assis-
tance.
19
Front heater Hi Limit
tripped.
Reset the front heat-
er Hi Limit switch.
20
Bad rear Solid State Relay. Contact Antunes
Technical Service
at +1-877-392-7854
(toll free) for assis-
tance.
21
Rear platen over-tempera-
ture condition.
22
Front platen over-tempera-
ture condition.