1.
Remove unit and all packing materials
from the shipping carton. If any
parts are missing or damaged,
contact Antunes Customer Service
IMMEDIATELY at +1-877-392-7856
(toll free).
2.
Remove the information packet.
3.
Remove all packing materials and
protective coverings.
4.
The unit should come with the items
listed below:
y
Owner’s Manual
y
Authorized Service Agency Directory
y
Handle and Handle Guard
y
Water Quick Disconnect Kit
5.
Wipe all surfaces of the unit with a hot
damp cloth. Do NOT use a dripping
wet cloth. Wring it out before use.
Remove and wash the Spatula and
Liner (Figure 1) in soap and water
by hand. Rinse with clean water and
allow to air dry.
6.
Assemble the Handle and Handle
Guard to the Spatula (Figure 1).
7.
Re-install the Spatula.
8.
Clean the accessories in hot, soapy
water. Rinse in clear water and allow
to air dry.
9.
Reassemble the unit.
10.
The unit must be level before use.
When placing the Cheese Melter into
service, pay attention to the following
guidelines.
y
Make sure the power switch is off
and the unit is at room temperature
before plugging in the power cord.
y
Do not block or cover any
openings on the unit.
y
Do not immerse the power
cord or plug in water.
y
Keep the power cord away
from heated surfaces.
y
Do not allow the power cord to hang
over edge of table or counter.
NOTE:
Plug the power cord into the
appropriate power outlet. Refer
to the specification plate for the
proper voltage.
Figure 1. CM-100 Spatula
Figure 2. Quick Disconnect
Figure 3. Chimney Drain Tubing
1.
Place the unit on a sturdy, level table
or other work surface.
2.
Turn off the power.
3.
Ensure the line voltage corresponds to
the stated voltage on the specification
label and power cord warning tag.
4.
Connect a length of 1/4” (6.5 mm) I.D.
flexible tubing (not supplied) to the
bottom of the Chimney as shown in
Figure 3. Secure using a hose clamp
(not supplied). Direct the other end of
the tubing to a drain.
5.
Connect the unit to the power supply.
Plumbing
The CM-100 requires installation of a
reverse osmosis filtration system for
supplying water to this equipment. To
purchase the filtration system, contact the
approved equipment distributor.
Flexible water line (not supplied) for water
hookup should be 1/4” (6.5 mm) I.D. to fit
the quick disconnect (supplied).
NOTE:
It is recommended to install
an in-line water strainer (P/N
7000333) to prevent debris from
entering the solenoid valve.
Debris in the solenoid valve will
cause a leaking condition that is
not covered by warranty.
1.
Connect the Flexible Tubing to the
Quick Disconnect Insert using the
supplied hose clamp.
2.
Push the Quick Disconnect Insert into
the female fitting on the back of the
unit until it clicks.
WARNING
Water pressure must not exceed 25
psi (1.7 kg/cm2 or 172 kPa). Higher
water pressures may cause poor
performance or flooding. To reduce
water pressure, install a water pressure
regulator, and set water pressure to
20–25 psi (1.4–1.7 kg/cm2 or 138–172
kPa).
WARNING
Connect this unit to a cold water supply
line only. Connecting this unit to a hot
water supply line will void the warranty.
USE
R.O
. WA
TER SUPP
LY O
NLY
Direct this end
to a Drain
Chimney
(rear of unit)
Chimney
Drain