background image

®

P/N 1011175 Rev. H 08/20

5

Installation

Unpacking

1. 

Remove unit and all packing materials 

from the shipping carton. If any 

parts are missing or damaged, 

contact Antunes Customer Service 

IMMEDIATELY at +1-877-392-7856 

(toll free).

2. 

Remove the information packet. 

3. 

Remove all packing materials and 

protective coverings.

4. 

The unit should come with the items 

listed below:

 

y

Owner’s Manual

 

y

Authorized Service Agency Directory

 

y

Handle and Handle Guard

 

y

Water Quick Disconnect Kit

5. 

Wipe all surfaces of the unit with a hot 

damp cloth. Do NOT use a dripping 

wet cloth. Wring it out before use. 

Remove and wash the Spatula and 

Liner (Figure 1) in soap and water 

by hand. Rinse with clean water and 

allow to air dry. 

6. 

Assemble the Handle and Handle 

Guard to the Spatula (Figure 1).

7. 

Re-install the Spatula. 

8. 

Clean the accessories in hot, soapy 

water.  Rinse in clear water and allow 

to air dry.

9. 

Reassemble the unit.

10. 

The unit must be level before use. 

When placing the Cheese Melter into 

service, pay attention to the following 

guidelines.

 

y

Make sure the power switch is off 

and  the unit is at room temperature 

before plugging in the power cord.

 

y

Do not block or cover any 

openings on the unit.

 

y

Do not immerse the power 

cord or plug in water.

 

y

Keep the power cord away 

from heated surfaces. 

 

y

Do not allow the power cord to hang 

over edge of table or counter.

NOTE:

 Plug the power cord into the 

appropriate power outlet. Refer 

to the specification plate for the 

proper voltage.

Figure 1. CM-100 Spatula

Figure 2. Quick Disconnect

Figure 3. Chimney Drain Tubing

1. 

Place the unit on a sturdy, level table 

or other work surface.

2. 

Turn off the power.

3. 

Ensure the line voltage corresponds to 

the stated voltage on the specification 

label and power cord warning tag.

4. 

Connect a length of 1/4” (6.5 mm) I.D. 

flexible tubing (not supplied) to the 

bottom of the Chimney as shown in 

Figure 3. Secure using a hose clamp 

(not supplied). Direct the other end of 

the tubing to a drain.

5. 

Connect the unit to the power supply.

Plumbing

The CM-100 requires installation of a 

reverse osmosis filtration system for 

supplying water to this equipment. To 

purchase the filtration system, contact the 

approved equipment distributor. 
Flexible water line (not supplied) for water 

hookup should be 1/4” (6.5 mm) I.D. to fit 

the quick disconnect (supplied).

NOTE:

 It is recommended to install 

an in-line water strainer (P/N 

7000333) to prevent debris from 

entering the solenoid valve. 

Debris in the solenoid valve will 

cause a leaking condition that is 

not covered by warranty. 

1. 

Connect the Flexible Tubing to the 

Quick Disconnect Insert using the 

supplied hose clamp.

2. 

Push the Quick Disconnect Insert into 

the female fitting on the back of the 

unit until it clicks.

    WARNING

Water pressure must not exceed 25 

psi (1.7 kg/cm2 or 172 kPa). Higher 

water pressures may cause poor 

performance or flooding. To reduce 

water pressure, install a water pressure 

regulator, and set water pressure to 

20–25 psi (1.4–1.7 kg/cm2 or 138–172 

kPa).

    WARNING

Connect this unit to a cold water supply 

line only. Connecting this unit to a hot 

water supply line will void the warranty.

USE 

R.O

. WA

TER SUPP

LY O

NLY

Direct this end

to a Drain

Chimney

(rear of unit)

Chimney

Drain

Summary of Contents for 9100416

Page 1: ...es com US E R O WAT ER SU PP LY ON LY Manufacturing Number 9100416 9100418 CAUTION Read all instructions before using the unit Original Instructions P N 1011175 Rev H 08 20 IPX3 RATING Mfg No 9100416 ONLY Certifications 9100418 ONLY Certifications ...

Page 2: ...n of this product contact Antunes Customer Service immediately at 1 877 392 7856 toll free Fill in the information in the next section and have it ready when calling for assistance The serial number is on the specification sticker located on the system Equipment Information to Save Purchased from Date of purchase Model number Serial number Manufacturing number Authorized Service Agency Name Phone ...

Page 3: ... supervised are not to play with the appliance y Bread may burn Therefore toasters must not be used near or below curtains or other combustible walls and materials Failure to maintain safe operating distances may cause discoloration or combustion y When opening the door of the cooking compartment hot steam can come out Maintenance y Do not use abrasive materials they can damage the unit s stainles...

Page 4: ...iption Configuration CM 100 9100416 NEMA 6 20P CM 100 9100418 CEE 7 7 Model Mfg No Volts Watts Amp Hertz CM 100 9100416 208 3300 16 50 60 CM 100 9100418 230 3300 16 50 60 Model Mfg No Width A Depth B Height C CM 100 9100416 9100418 17 3 8 441 mm 17 5 8 448 mm 8 3 8 213 mm Dimensions USE R O WATE R SUPPLY ONLY C A B ...

Page 5: ...ure 2 Quick Disconnect Figure 3 Chimney Drain Tubing 1 Place the unit on a sturdy level table or other work surface 2 Turn off the power 3 Ensure the line voltage corresponds to the stated voltage on the specification label and power cord warning tag 4 Connect a length of 1 4 6 5 mm I D flexible tubing not supplied to the bottom of the Chimney as shown in Figure 3 Secure using a hose clamp not sup...

Page 6: ...t for the entire steaming cycle 4 At the end of the steaming cycle approximately 7 seconds an audible signal will sound until the Spatula is removed from the unit and the green Ready Light will turn back on indicating the product is ready to be served 5 Carefully remove the steamed product and insert the Spatula back into the unit Hi Limit Thermostat A hi limit thermostat will turn off electrical ...

Page 7: ...are needed for proper operation but a buildup of excessive mineral deposits causes poor steaming efficiency and excessive moisture wet steam and will eventually severely hinder the steaming action Cleaning Steam Generator 1 Turn the power off unplug the power cord and allow the unit to cool down 2 Remove the Top Cover 3 Remove the Wing Nut and Generator Cover 4 Remove the Diffuser 5 Examine all st...

Page 8: ...the amount of water volume used per cycle and counterclockwise decreases the amount NOTE The Water Volume Control is numbered 0 9 and is preset to 6 With each turn the unit will beep 3 Plug in the power cord and test the unit before returning it to service NOTE If the steamer does not steam properly after calibration refer to the Troubleshooting section of this manual WARNING Excessive force will ...

Page 9: ...the Quick Disconnect Insert from teh rear of the unit While holding into an empty cup press the white plastic tip for 5 continuous seconds A strong steady water flow should be noted If so re engage firmly into the unit If not present or low pressure contact your maintenance person or plumber Solenoid valve coil is defective Contact your local Authorized Service Agency Control Board inoperable or p...

Page 10: ... Control Board inoperable or problematic Loose burnt or broken wires in heater circuit Circuit is wired incorrectly Unit does not operate power switch is on but light is off Unit unplugged Plug power cord into the appropriate outlet Circuit breaker is off Reset the circuit breaker Power cord defective or inoperable Contact your local Authorized Service Agency Power switch defective or inoperable G...

Page 11: ... P N 1011175 Rev H 08 20 11 Wiring Diagram Mfg No 9100416 ...

Page 12: ... P N 1011175 Rev H 08 20 12 Wiring Diagram Mfg No 9100418 ...

Page 13: ...0503433 Generator Cover 1 37 325P170 Wing Nut 1 4 20 1 Replacement Parts Parts List See Exploded Views for more information NOTICE Use only genuine Antunes replacement parts in this unit Use of parts other than those supplied by the manufacturer will void the warranty Item No Part Description Qty 38 0300129 Stud Cover 1 39 306P134 Mach Screw 6 32 x 3 8 3 40 0503472 Hi Limit Support Bracket 1 41 70...

Page 14: ...7 13 37 46 45 44 34 58 69 1 43 21 17 52 54 53 34 56 50 51 18 67 19 49 40 34 16 51 20 34 11 3 2 12 59 80 61 4 8 71 31 41 28 30 29 36 62 15 55 57 22 34 39 14 P N 0100280 74 P N 0200311 75 P N 0200310 79 P N 0200324 77 P N 3080104 76 P N 0021923 78 P N 0200323 77 P N 3080104 ITEMS SPECIFIC TO MFG NO 9100417 ...

Page 15: ... P N 1011175 Rev H 08 20 15 NOTES ...

Page 16: ...t authorized service agency 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim directly upon the carrier Care...

Reviews: