background image

Limited Warranty

Equipment manufactured by Antunes has been constructed of the finest materials available and manufactured to 

high quality standards.  These units are warranted to be free from electrical and mechanical defects for a period of 

one (1) year from date of purchase under normal use and service, and when installed in accordance with manufac

-

turer’s recommendations.  To insure continued operation of the units, follow the maintenance procedures outlined 

in the Owner’s Manual.  During the first 12 months, electromechanical parts, non-overtime labor, and travel ex

-

penses up to 2 hours (100 miles/160 km), round trip from the nearest Authorized Service Center are covered.

1. 

This warranty does not cover cost of installation, defects caused by improper storage or handling prior to plac

-

ing of the Equipment.  This warranty does not cover overtime charges or work done by unauthorized service 

agencies or personnel.  This warranty does not cover normal maintenance, calibration, or regular adjust

-

ments as specified in operating and maintenance instructions of this manual, and/or labor involved in moving 

adjacent objects to gain access to the equipment.  This warranty does not cover consumable/wear items. This 

warranty does not cover damage to the Load Cell or Load Cell Assembly due to abuse, misuse, dropping of 

unit/shock loads or exceeding maximum weight capacity (4 lbs).  This warranty does not cover water con

-

tamination problems such as foreign material in water lines or inside solenoid valves.  It does not cover water 

pressure problems or failures resulting from improper/incorrect voltage supply.   This warranty does not cover 

Travel Time & Mileage in excess of 2 hours (100 miles/160 km) round trip from the nearest authorized service 

agency. 

2. 

Antunes reserves the right to make changes in design or add any improvements on any product.  The right 

is always reserved to modify equipment because of factors beyond our control and government regulations.  

Changes to update equipment do not constitute a warranty charge.

3. 

If shipment is damaged in transit, the purchaser should make a claim directly upon the carrier.  Careful inspec

-

tion should be made of the shipment as soon as it arrives and visible damage should be noted upon the car

-

rier’s receipt.  Damage should be reported to the carrier.  This damage is not covered under this warranty.

4. 

Warranty charges do not include freight or foreign, excise, municipal or other sales or use taxes.  All such 

freight and taxes are the responsibility of the purchaser.  

5. 

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR 

IMPLIED, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICU

-

LAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED.  THE REMEDIES DESCRIBED 

ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL ANTUNES BE LIABLE FOR SPECIAL CONSEQUEN

-

TIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE OF THIS WAR

-

RANTY.

The warranty does not extend to:

 

y

Damages caused in shipment

 

y

Installation of electrical service

 

y

Installation, calibration, or adjustment

 

y

Normal maintenance outlined in this manual

 

y

Consumable parts such as egg rings, gaskets, rubber feet, labels, O-rings, light bulbs, etc.

 

y

Malfunction resulting from improper service or maintenance

 

y

Damage caused by improper installation, improper use, abuse, or careless handling

 

y

Damage from moisture coming in contact with electrical components

 

y

Damage from tampering with, removal of, or changing preset controls or safety devices

 

y

Damage caused by parts or components not  provided by Antunes

+1 (630) 784-1000

+1 (800) 253-2991

+1 (630) 784-1650

+86-512-6841-3907

+86-512-6841-3637

®

Summary of Contents for 9100416

Page 1: ...es com US E R O WAT ER SU PP LY ON LY Manufacturing Number 9100416 9100418 CAUTION Read all instructions before using the unit Original Instructions P N 1011175 Rev H 08 20 IPX3 RATING Mfg No 9100416 ONLY Certifications 9100418 ONLY Certifications ...

Page 2: ...n of this product contact Antunes Customer Service immediately at 1 877 392 7856 toll free Fill in the information in the next section and have it ready when calling for assistance The serial number is on the specification sticker located on the system Equipment Information to Save Purchased from Date of purchase Model number Serial number Manufacturing number Authorized Service Agency Name Phone ...

Page 3: ... supervised are not to play with the appliance y Bread may burn Therefore toasters must not be used near or below curtains or other combustible walls and materials Failure to maintain safe operating distances may cause discoloration or combustion y When opening the door of the cooking compartment hot steam can come out Maintenance y Do not use abrasive materials they can damage the unit s stainles...

Page 4: ...iption Configuration CM 100 9100416 NEMA 6 20P CM 100 9100418 CEE 7 7 Model Mfg No Volts Watts Amp Hertz CM 100 9100416 208 3300 16 50 60 CM 100 9100418 230 3300 16 50 60 Model Mfg No Width A Depth B Height C CM 100 9100416 9100418 17 3 8 441 mm 17 5 8 448 mm 8 3 8 213 mm Dimensions USE R O WATE R SUPPLY ONLY C A B ...

Page 5: ...ure 2 Quick Disconnect Figure 3 Chimney Drain Tubing 1 Place the unit on a sturdy level table or other work surface 2 Turn off the power 3 Ensure the line voltage corresponds to the stated voltage on the specification label and power cord warning tag 4 Connect a length of 1 4 6 5 mm I D flexible tubing not supplied to the bottom of the Chimney as shown in Figure 3 Secure using a hose clamp not sup...

Page 6: ...t for the entire steaming cycle 4 At the end of the steaming cycle approximately 7 seconds an audible signal will sound until the Spatula is removed from the unit and the green Ready Light will turn back on indicating the product is ready to be served 5 Carefully remove the steamed product and insert the Spatula back into the unit Hi Limit Thermostat A hi limit thermostat will turn off electrical ...

Page 7: ...are needed for proper operation but a buildup of excessive mineral deposits causes poor steaming efficiency and excessive moisture wet steam and will eventually severely hinder the steaming action Cleaning Steam Generator 1 Turn the power off unplug the power cord and allow the unit to cool down 2 Remove the Top Cover 3 Remove the Wing Nut and Generator Cover 4 Remove the Diffuser 5 Examine all st...

Page 8: ...the amount of water volume used per cycle and counterclockwise decreases the amount NOTE The Water Volume Control is numbered 0 9 and is preset to 6 With each turn the unit will beep 3 Plug in the power cord and test the unit before returning it to service NOTE If the steamer does not steam properly after calibration refer to the Troubleshooting section of this manual WARNING Excessive force will ...

Page 9: ...the Quick Disconnect Insert from teh rear of the unit While holding into an empty cup press the white plastic tip for 5 continuous seconds A strong steady water flow should be noted If so re engage firmly into the unit If not present or low pressure contact your maintenance person or plumber Solenoid valve coil is defective Contact your local Authorized Service Agency Control Board inoperable or p...

Page 10: ... Control Board inoperable or problematic Loose burnt or broken wires in heater circuit Circuit is wired incorrectly Unit does not operate power switch is on but light is off Unit unplugged Plug power cord into the appropriate outlet Circuit breaker is off Reset the circuit breaker Power cord defective or inoperable Contact your local Authorized Service Agency Power switch defective or inoperable G...

Page 11: ... P N 1011175 Rev H 08 20 11 Wiring Diagram Mfg No 9100416 ...

Page 12: ... P N 1011175 Rev H 08 20 12 Wiring Diagram Mfg No 9100418 ...

Page 13: ...0503433 Generator Cover 1 37 325P170 Wing Nut 1 4 20 1 Replacement Parts Parts List See Exploded Views for more information NOTICE Use only genuine Antunes replacement parts in this unit Use of parts other than those supplied by the manufacturer will void the warranty Item No Part Description Qty 38 0300129 Stud Cover 1 39 306P134 Mach Screw 6 32 x 3 8 3 40 0503472 Hi Limit Support Bracket 1 41 70...

Page 14: ...7 13 37 46 45 44 34 58 69 1 43 21 17 52 54 53 34 56 50 51 18 67 19 49 40 34 16 51 20 34 11 3 2 12 59 80 61 4 8 71 31 41 28 30 29 36 62 15 55 57 22 34 39 14 P N 0100280 74 P N 0200311 75 P N 0200310 79 P N 0200324 77 P N 3080104 76 P N 0021923 78 P N 0200323 77 P N 3080104 ITEMS SPECIFIC TO MFG NO 9100417 ...

Page 15: ... P N 1011175 Rev H 08 20 15 NOTES ...

Page 16: ...t authorized service agency 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim directly upon the carrier Care...