12. GATE LENGTH PAGE
Gate length page is accessed by long pressing button C,
and is indicated by LED C blinking.
Here you can set the gate length with the step buttons.
Gate length is a percentage value calculated from the time
between two clock inputs. The values selectable from this
page are the following:
1 5%
2 13%
3 25%
4 38%
5 50%
6 63%
7 75%
8 88%
Summary of Contents for ROT8