To calibrate an Atomic Master Clock, ensure atomic signal is fed to the OCX HD's Atomic Input, the
Atomic Clock is warmed up and the OCX HD Atomic Clock Indicator is lit.
1.Click 'Calibration' and the device will enter calibration mode
2. The indicator below will show a number which will stabilize with time. Wait for the number to
become stable. This number represents the error of the OCX HD's clock related to the Atomic Clock.
To compensate for this error, click the 'Calibrate' button.
3. Repeat the procedure as many times as necessary so that the number becomes as close as
possible to 0 and relatively stable (it may have small deviations of a few seconds). To exit Calibration
Mode, press the
X
button.
Panel lock indicator
You can lock or unlock the Control Panel by clicking on the Pad Lock symbol. When the Control Panel
is locked, the device will not accept commands from its front panel interface and/or the application,
thus preventing accidental changes during sessions or live events.
Info button
Displays Control Panel version, hardware version, device serial number, and firmware version. You
can also launch the Firmware Update wizard to check for and initiate firmware updates.