background image

 

- 5 -

light normally. Please always replace a full fluid bladder. Otherwise, it might damage the pump of 

generator. 

 

 

 

 

 

 

 

LED & Buzzer Status Table

 

Machine Status 

Buzzer 

LED 

Machine Overheating 

1 short beep every 5 sec. 

Red flash twice every 2 sec. 

Front Cover or Fluid Bag 

Chamber Cover is Opened 

1 long beep every 1 min. 

Red flash once every 2 sec. 

UPS Power Cut 

3 short beeps every 30 sec. 

Red flash twice every 5 sec. 

AC Power Cut 

2 short beeps every 30 sec. 

Red flash once every 5 sec. 

Heater Fault 

1 long beep every 10 sec. 

Red flash 

Fluid Level Empty 

1 long and 1 short beep every 5 min. 

Orange flash   

Fluid Level Low 

1 short beep every 5 min. 

Permanent orange   

Heating Process incomplete 

Long beep for 30 sec. and then 3 short 

beeps every 5 min. 

Permanent red   

DIP 2 switch to ON 

No buzzer 

Red and green flash together 

Normal 

No buzzer 

Permanent green 

Armed 

No buzzer 

Green light flashes slowly 

 

Test the security smoke generator 

Once Antari security smoke generators reach ready status (Green LED On), you can carry out a simple 

test at generators to check the smoke production. 

Open the front cover, and press and hold down the “PB1“test button. The machine will produce smoke. 

Smoke production ceases once the “PB1”test button is released. 

 

Thank you very much again for your patience and reading this manual. If you have any further question 

about our products, please do not hesitate to contact your local distributor or Antari directly.   

 

Antari contact information 

Email: 

[email protected]

  Tel: +886-3-322-5829  Fax:+886-3-322-7035 

No. 8, Lane 231, Nankan Rd., Sec.1, Lujhu, Taoyuan county, Taiwan 

Summary of Contents for SFX-1000

Page 1: ...0...

Page 2: ...tment Otherwise residue might be caused Package Before starting installation Antari security smoke generator please make sure that you have all the following equipments 1 Antari security smoke generat...

Page 3: ...f the machine is activated This signal can notice the security control center that the unit is producing smoke Or this connection can be wired to another security smoke machine When the unit starts to...

Page 4: ...gether to activate the smoke generator When all Hold Alarm and Trigger three terminal blocks are closed circuit the machine will start to produce smoke Generally this terminal can be set as a switch R...

Page 5: ...whole process is totally finished Set Up Duration of Smoke Output Switch DIP switch No 2 to ON Press PB1 for 5 seconds After twice short beep every press of PB1 can add 15 seconds The duration of smok...

Page 6: ...ep for 30 sec and then 3 short beeps every 5 min Permanent red DIP 2 switch to ON No buzzer Red and green flash together Normal No buzzer Permanent green Armed No buzzer Green light flashes slowly Tes...

Page 7: ...6 SFX 1000 SFX 1500 Antari 50 Antari 1 Antari 1 1 1 Antari Alarm Trigger Hold off Alarm Trigger Hold off PIR Alarm Trigger Hold off Alarm Trigger...

Page 8: ...larm Trigger PIR PIR Alarm Trigger Hold off Verification COM NO NC COM NO COM NC UPS COM NO NC COM NO UPS UPS COM NC UPS Low COM NO NC COM NO Ready COM NC UPS COM NO NC COM NO COM NC UPS Trigger Alarm...

Page 9: ...8 RIR 12V 100mA LED F U L R ON OFF NO NC COM NO NC COM NO NC COM NO NC COM TAMPER 12VDC 100mA Hold Verification FOG UPS LOW Ready Trigger Alarm Alarm Trigger Hold off Alarm Trigger Hold off PIR...

Page 10: ...9 DIP1 ON Alarm Trigger Hold off PIR Alarm DIP2 UPS 2 ON LED PB2 10 2 OFF UPS 2 ON PB1 5 PB1 15 15 360 2 OFF OUT LED LED 5 1 2 2 1 1 2 1 UPS 30 3 5 2 AC 30 2 5 1 10 1 5 1 1 5 1 30 5 3 2 ON...

Page 11: ...10 Antari LED PB1 Antari Antari Email sales antari com 886 3 322 5829 886 3 322 0433 231 8...

Page 12: ...11 C08SFX102...

Reviews: