- 3 -
security control center, the relay will give a signal of closed circuit if the smoke machine
completes the heating process. This signal can notice the security control center that the
smoke machine is ready.
If COM and NC are wired, the reverse signal (open circuit) will be sent out.
Trigger
This terminal can work with
Alarm
and
Hold
together to activate the smoke generator.
When all
Hold
,
Alarm
, and
Trigger
, three terminal blocks are closed circuit, the machine
will start to produce smoke.
Generally, this terminal can be set as a switch. Releasing the switch (Making it open
circuit) can stop smoking.
Alarm
This terminal can work with
Trigger
and
Hold
together to activate the smoke generator.
When all
Hold
,
Alarm
, and
Trigger
, three terminal blocks are closed circuit, the machine
will start to produce smoke. Generally, this terminal can be set as a switch. Releasing the
switch (Making it open circuit) can stop smoking.
◎
Example for PCB connection
}
}
RIR ( M otion detector)
12V/100mA DC input
(Please notice positive and negative)
Activated signal
Change of status displayed by LED
F
U
L
R
ON/OFF
Activated signal
Change of status
signal output
Switch
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
TAM PER
12VDC/100mA
Hold
Verification
FOG
UPS
LOW
Ready
Trigger
Alarm
Notice:
When Trigger, Alarm, and Hold are activated at the same time (All are closed circuit),
the generator will start to produce smoke.
In order to stop making smoke, either Trigger or Alarm has to be removed (Open circuit).
Only removing Hold cannot stop smoking.