SFX-1000 & SFX-1500   

Security Smoke Generator User Manual 

 

Thank you for choosing Antari security smoke generator. Please read this instruction carefully prior to 

operation. 

 

Warning! 

* 

Hot nozzle! Keep at least 50 cm distance. 

* 

The heater of the generator is extremely hot. Please be careful when the front cover is opened. 

* 

No user serviceable parts inside. Please contact with an authorized dealer when maintenance is 

required. 

* 

Please disconnect power before change fuse. 

* 

Please operate only with adult supervision. 

* 

Only Antari smoke fluid should be used. Other fluid may damage the equipment or cause dangers 

to human physical safety. 

* 

Do not use without smoke fluid. 

* 

For indoor use only. Please keep dry. 

* 

Please clear smoke away from room after an ejectment. Otherwise, residue might be caused. 

 

Package 

Before starting installation Antari security smoke generator, please make sure that you have all the 

following equipments: 

● 

1 × Antari security smoke generator 

● 

1 × Smoke fluid bladder 

● 

1 × Mounting set 

● 

1 x User Manual   

 

Controlling of Smoke 

The three sets of terminal blocks on the PCB of Antari smoke generators, Alarm, Trigger, and Hold-off 

are the keys to generate smoke. In order for generator to produce smoke in the critical moment, the 

three sets of connections must be closed circuit at the same time, which can avoid wrong action of 

making smoke. For instance, both Alarm and Trigger can be set up as switches on the security system 

control panel. On the other hand, Hold-off usually can be connected to a PIR (motion detector) or a 

window/door sensor. However, please note in order to stop making smoke, either Trigger or Alarm has 

to be released (open circuit). Only releasing Hold-off cannot stop smoking. 

 

Summary of Contents for SFX-1000

Page 1: ...0...

Page 2: ...tment Otherwise residue might be caused Package Before starting installation Antari security smoke generator please make sure that you have all the following equipments 1 Antari security smoke generat...

Page 3: ...f the machine is activated This signal can notice the security control center that the unit is producing smoke Or this connection can be wired to another security smoke machine When the unit starts to...

Page 4: ...gether to activate the smoke generator When all Hold Alarm and Trigger three terminal blocks are closed circuit the machine will start to produce smoke Generally this terminal can be set as a switch R...

Page 5: ...whole process is totally finished Set Up Duration of Smoke Output Switch DIP switch No 2 to ON Press PB1 for 5 seconds After twice short beep every press of PB1 can add 15 seconds The duration of smok...

Page 6: ...ep for 30 sec and then 3 short beeps every 5 min Permanent red DIP 2 switch to ON No buzzer Red and green flash together Normal No buzzer Permanent green Armed No buzzer Green light flashes slowly Tes...

Page 7: ...6 SFX 1000 SFX 1500 Antari 50 Antari 1 Antari 1 1 1 Antari Alarm Trigger Hold off Alarm Trigger Hold off PIR Alarm Trigger Hold off Alarm Trigger...

Page 8: ...larm Trigger PIR PIR Alarm Trigger Hold off Verification COM NO NC COM NO COM NC UPS COM NO NC COM NO UPS UPS COM NC UPS Low COM NO NC COM NO Ready COM NC UPS COM NO NC COM NO COM NC UPS Trigger Alarm...

Page 9: ...8 RIR 12V 100mA LED F U L R ON OFF NO NC COM NO NC COM NO NC COM NO NC COM TAMPER 12VDC 100mA Hold Verification FOG UPS LOW Ready Trigger Alarm Alarm Trigger Hold off Alarm Trigger Hold off PIR...

Page 10: ...9 DIP1 ON Alarm Trigger Hold off PIR Alarm DIP2 UPS 2 ON LED PB2 10 2 OFF UPS 2 ON PB1 5 PB1 15 15 360 2 OFF OUT LED LED 5 1 2 2 1 1 2 1 UPS 30 3 5 2 AC 30 2 5 1 10 1 5 1 1 5 1 30 5 3 2 ON...

Page 11: ...10 Antari LED PB1 Antari Antari Email sales antari com 886 3 322 5829 886 3 322 0433 231 8...

Page 12: ...11 C08SFX102...

Reviews: