Antaira Technologies - Industrial Ethernet Switches
LNP-0500G-bt-24 Series User Manual V1.1
7
[Notice]
When the relay is triggered because of Event 2~5, the relay contact alarm, will update the status
every 30 seconds. If there’s no event happening for 30 seconds, the relay contact alarm will be turn
off. If the user disables the failed PoE port by removing the cable or Dip Switch manually, the relay
will be recovered immediately.
2.7 PoE Port LED Indicators
The LED light indicators on the PoE copper port can help the user know if an event once occurs or
is happening. When the event is happening, user can verify the event from the Dual-color LED
status. If the port has recovered from an event, user can verify the event from the blinking
frequency of the PoE LED(5 seconds as a cycle,).
•
Power Budget Exceeded Event
When the total PoE budget is overload (>100%), the PoE port of the lowest priority PoE port will be
shutdown. The PoE LED of the port will act cyclically as below until the port is recovered from the
event:
After the PoE port is recovered from the PoE budget overload event, the PoE LED of the will act
cyclically as below until the event indicator is clear manually:
**AF/AT: Amber; BT: Green
•
PoE Port Over Current Event (PoE Port Overload Event)
When the current limit of the specific PoE port is exceeded, the PoE power will be shutdown.
The PoE LED of the port will act cyclically as below until the port is recovered from the event:
**AF/AT: Amber; BT: Green