[RPL Owner Node]
There is only one RPL owner node that should be set in a ring network. In order to set up the
RPL owner node, choose a switch and enable
the “Protocol” under the ERPS configuration
interface, and then follow the steps below using
Figure 5.25
as an example.
Step 1:
Choose a specific port from the dropdown box next to “ring port 0”, and set it as
the
“Owner” node by clicking the dropdown box next to “Role” which is below
“ring port 0”. At this point, “
Port 1
” has been chosen as an example.
Step 2:
Choose a specific port from the dropdown box next to “ring port 1”, then set it as
“
Normal
” from the dropdown box next to “Role” (which is located below “ring
port 1”). At this point, “
Port 2
” has been chosen as an example.
Note:
The port number of “Ring Port 0” and “Ring Port 1” cannot be duplicated.
After the configurations, press the “Apply” button on the right bottom corner to save the
setting.
Please note
when the revertive mode is set to “
Yes
”, the ring will recover the same
information as shown in
Figure 5.24,
after the ring state will go from ABNORMAL to NORMAL
within 5 minutes. Otherwise, the blocked port will remain permanently blocked unless users
reconfigure it.
Figure 5.25
– RPL Owner Node Setup Example