Antaira Industrial Ethernet Switches
LMP-0501 Series User Manual V1.0
20
Terms
Value Description
Port No.
PoE port number
Status
Any PoE port will automatically detect any powered device (PD) that
is connected and it will display the situation.
Mode
Users can use the dropdown box to enable or disable any PoE port
function.
Consumption
Set the PoE power output limit value. The maximum value must less
than 30.0W.
Click the
“Apply” button to save changes.
5.4.2 Ping Alarm
The PoE ping alarm function is using the ping command to turn on or off any PoE power output
port. Users can insert any particular powered device’s IP address and set the interval time for a
power recycle, timing the particular PoE port.
Figure 5.15
– PoE Port Configuration Description
Figure 5.16
– PoE Ping Alarm Interface