NiCd-BATTERIES
NiCd CHARGE
Push the button “BATT TYPE” until the display shows “NiCd”. Now use the “INC” or “DEC” button to get to “CHARGE” and then push “ENTER”
to confirm. After your confirmation the display will change to the capacity “CAP”. Now please set the capacity of your battery with the
buttons “INC” or “DEC” from 100 mAh to 5000 mAh and confirm with “ENTER”. The display changes to the charge current “C” which can be
set with the “INC” or “DEC” buttons from 0.1 A to 5.0 A. The parameters shown on the display are set and stop flashing if no push button is
pressed for 3 seconds. To start charging, now push the “ENTER / START / STOP” button for 2 seconds. The display shows “BATTERY CHECK
WAIT PLEASE“. After a short check of all parameters the display shows the battery type “NC”, the charge mode “CHG”, the charge current e.g.:
“+1.50A” and the actual measured battery voltage “V”. The clock starts running in seconds and the display shows also the charged capacity.
When the charging is finished you will get an audible signal. The display shows the trickle charge current and the capacity charged into the battery.
NiCd DISCHARGE
Push the button “BATT TYPE” until the display shows “NiCd”. Now use the “INC” or “DEC” button to get to “DISCHARGE” and then push “ENTER” to
confirm. After your confirmation the display will change to the discharge current “D”. Now please set the discharge current with the buttons “INC” or
“DEC” from 0.10 A to 1.00 A and confirm with “ENTER”. The display changes to the discharge voltage “V” which can be set with the “INC” or “DEC”
buttons from 0.1 V to 16.8 V. We recommend a discharge voltage of 0.9 V/cell. The parameters shown on the display, are set and stop flashing if no
push button is pressed for 3 seconds. To start discharging, now push the “ENTER / START / STOP” button for 2 seconds. The display shows “BATTERY
CHECK WAIT PLEASE“. After a short check of all parameters the display shows the battery type “NC”, the discharge mode “DIS”, the discharge current
e.g.: “+1.00A” and the actual measured battery voltage “V”. The clock starts running in seconds and the display shows also the discharged capacity.
When the discharging is finished you will get an audible signal. The display shows the discharged capacity from the battery.
NiCd CYCLE
Within the CYCLE MODE you can choose between 2 options;
a) “C→D“ to identify the battery capacity. The battery will be charged first and then discharged.
b) “C←D“ as a Refresh-function. The battery will be discharged first and then charged.
Push the button “BATT TYPE” until the display shows “NiCd”. Now use the “INC” or “DEC” button to get to “CYCLE” and than push “ENTER” to confirm.
After your confirmation the display will change to the cycle mode. Now please set the cycle mode with the buttons “INC” or “DEC” from “C→D“ or “C←
D“ and confirm with “ENTER”. The display changes now to the number of cycles which can be set with the “INC” or “DEC” buttons from 1 to 5. After
your confirmation the display will change to the capacity “CAP”. Now please set the capacity of your battery with the buttons “INC” or “DEC” from
100 mAh to 5000 mAh and confirm with “ENTER”. The display changes to the charge current “C” which can be set with the “INC” or “DEC” buttons
from 0.1 A to 5.0 A. After your confirmation the display will change to the discharge current “D”. Now please set the discharge current with the buttons
“INC” or “DEC” from 0.10 A to 1.00 A and confirm with “ENTER”. The display changes to the discharge voltage “V” which can be set with the “INC” or
“DEC” buttons step less from 0.1 V to 16,8 V. We recommend a discharge voltage of 0.9 V/cell. The parameters shown on the display are set and stop
flashing if no push button is pressed for 3 seconds.
Now push the “ENTER / START / STOP” button for 2 seconds. Within the cycle mode “C←D“ the charger starts with discharge. The display shows
“BATTERY CHECK WAIT PLEASE“. After a short check of all parameters the display shows the battery type “NC”, the cycle mode “C←D“ (C→D), the
discharge current e.g.: “+1.00A” and the actual measured battery voltage “V”. The clock starts running in seconds and the display shows also the
discharged capacity.
7
1_manual_xmove_06-12.indd 8
1_manual_xmove_06-12.indd 8
11.01.2007 16:45:39 Uhr
11.01.2007 16:45:39 Uhr
Prozessfarbe Schwarz
Prozessfarbe Schwarz